Whirlpool WEG750H0HW, WEG750H0HZ, WEG750H0HV Installation Manual

30" (76.2 cm) Slide-In Gas Range Installation Instructions
PRODUCT MODEL NUMBERS
WEG750H0H
Product Dimensions
These instructions cover several models. Your model may appear different from the models depicted. Dimensions given are maximum dimensions across all models.
Model WEG750
A
E
F
B
C
D
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth, and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Range may be installed next to combustible walls with zero clearance. NOTE: When installed in a slide-in cutout, the front of oven door may
protrude beyond the base cabinet.
Slide-In Cutout
D
B
C
N
A
E
M
F
A. 1³⁄16" (3.0 cm) height from cooktop
to top of vent B. 297⁄8" (75.9 cm) C. Model/serial/rating plate (located
behind the oven door on the top
right-hand side of the oven frame) D. 36" (91.4 cm) height to top of
cooktop edge with leveling legs
screwed in all the way*
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
E. 27" (68.8 cm) max. depth
from front of console to back of range
F. 285/8" (72.7 cm) max. depth
from handle to back of range
H
I
G
L
K
J
A. 18" (45.7 cm) upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see NOTE*. E. 30" (76.2 cm) min. opening width F. 3" (7.6 cm) min. clearance from both sides of range to side wall or
other combustible material
G. The shaded area is recommended for installation of rigid gas pipe
and grounded outlet. H. 13¹⁄8" (33.3 cm) I. 7¹¹⁄16" (19.5 cm) J. 4¹³⁄16" (12.2 cm) K. 3¹¹⁄16" (9.4 cm) plus measurement of N L. 12" (30.5 cm) M. Cabinet door or hinges should not extend into the cutout. N. Remaining counter depth should not exceed 2¼" (5.7 cm)
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is shielded by not less than 1/4" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
05/18/2017
ELECTRICAL REQUIREMENTS
A
C
■ A 120 volt, 60 Hz., AC only, 15-amp fused, ground and polarized
electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
■ Electronic ignition systems operate within wide voltage limits, but
proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
GAS SUPPLY REQUIREMENTS
Gas Supply Line
■ Provide a gas supply line of 3/4" (19 mm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient gas supply. With propane gas, piping or tubing size can be 1/2" (13 mm) minimum. Usually, propane gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of propane gas must be used. Do not use TEFLON®† tape.
Flexible Metal Appliance Connector:
■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, 1/2" or 3/4" (13 or 19 mm) I.D. (inside diameter), flexible metal appliance connector may be used for connecting range to the gas supply line.
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.6 cm) WCP
Propane Gas:
Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14” (35.6 cm) WCP
Contact local gas supplier if you are not sure about the inlet pressure.
■ A 1/2" (13 mm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
■ Do not kink or damage the flexible metal tubing when moving the
range.
■ Must include a shut-off valve:
Install a manual gas line shut-off valve in an easily accessible location. Do not block access to shut-off valve. The valve is for turning on or shutting off gas to the cooktop.
B
A. Gas supply line B. Shut-off valve open position C. To range
†®TEFLON is a registered trademark of Chemours.
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 2 of 2
05/18/2017