Whirlpool WEG745H0FS, WEG760H0DS, WEG760H0DH, WEG760H0DE, WEG730H0DW Dimension Guide

...
A
C
30" (76.2 cm) Slide-in Gas Range
A
PRODUCT MODEL NUMBERS
GAS SUPPLY REQUIREMENTS
Gas supply line:
■ Provide a gas supply line of
size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be 1⁄2" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.
Flexible metal appliance connector:
■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long,
(1.3 cm) or 3⁄4" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
1
■ A
⁄2" (1.3 cm) male pipe thread is needed for connection to the female pipe threads
of the inlet to the appliance pressure regulator.
■ Do not kink or damage the flexible metal tubing when moving the range.
■ Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
3
⁄4" (1.9 cm) rigid pipe to the range location. A smaller
B
A. Gas supply line B. Shutoff valve “open” position C. To range
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:
Natural gas: Minimum pressure: 5" WCP Maximum pressure: 14" WCP
LP gas: Minimum pressure: 11" WCP Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet pressure.
PRODUCT DIMENSIONS
This manual covers several models. Your model may appear different from the models depicted. Dimensions given are maximum dimensions across all models.
B
1
⁄2"
C
D
E
F
A. 13⁄16" (3.0 cm) height from
cooktop to top of vent B. 297⁄8" (75.9 cm) C. Model/serial number plate
(located behind the oven door
on the top right-hand side of
the oven frame) D. 36" (91.4 cm) height to top of
cooktop edge with leveling
legs screwed all the way in*
IMPORTANT: Range must be level after installation. Follow the instructions in the “Level Range” section. Using the cooktop as a reference for leveling the range is not recommended. * Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
E. 28 5⁄16" (71.9 cm) max. depth
from front of console to back of range.
F. 287⁄8" (73.3 cm) max. depth
from handle to back of range.
Type of Gas
Natural gas:
■ This range is factory set for use with Natural gas. See “Gas Conversions” section.
The model/serial rating plate located behind the control panel has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
†®
TEFLON is a registered trademark of Chemours.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
Ref. W10665256E
5/16
ELECTRICAL REQUIREMENTS
IMPORTANT: The range must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Range may be installed next to combustible walls with zero clearance.
NOTE: When installed in a slide-in cutout, the front of oven door may protrude beyond the base cabinet.
A. 18" (45.7 cm) upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see NOTE*. E. 30" (76.2 cm) min. opening width F. 3" (7.6 cm) min. clearance from both sides of range to side
wall or other combustible material.
G. The shaded area is recommended for installation of rigid
gas pipe and grounded outlet. H. 131⁄8" (33.3 cm) I. 711⁄16" (19.5 cm) J. 413⁄16" (12.2 cm) K. 311⁄16" (9.4 cm) or measurement of N, whichever is greater L. 12" (30.5 cm) M. Cabinet door or hinges should not extend into the cutout. N. Remaining counter depth should not exceed 21/4" (5.7 cm)
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by
not less than 1⁄4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
■ A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
■ Electronic ignition systems operate within wide voltage limits, but proper grounding
and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
D
B
C
N
A
E
M
F
H
I
G
L
K
J
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 2 of 2
Ref. W10665256E
5/16
Loading...