Whirlpool WEG515S0LV, WEG515S0LS PRODUCT SPECIFICATIONS

Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W11508844A
04/19/2021
Page 1 of 2
A
C
PRODUCT MODEL NUMBERS
WEG515S0L
GAS SUPPLY REQUIREMENTS
Gas supply line:
■ Provide a gas supply line of
location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be minimum. Usually, LP gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON
3
/4" (1.9 cm) rigid pipe to the range
1
/2" (1.3 cm)
®†
tape.
Flexible metal appliance connector:
■ If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, appliance connector may be used for connecting range to the gas supply line.
1
■ A
/2" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
■ Do not kink or damage the flexible metal tubing when moving the
range.
■ Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
1
/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal
B
PRODUCT DIMENSIONS
This manual covers several models. Your model may appear different from the models depicted. Dimensions given are maximum dimensions across all models.
A
B
C
D
E
F
25
A. 13/16" (3.0 cm) height from
cooktop to top of vent
7
B. 29
/8" (75.9 cm)
C. Model/serial number plate
(located behind the oven door on the top right-hand side of the oven frame)
D. 36" (91.4 cm) height to
top of cooktop edge with leveling legs screwed all the way in*
E. 28
/64" (72.1 cm) max. depth from front of console to back of range.
1
F. 29
/64" (73.7 cm) max. depth from handle to back of range.
A. Gas supply line B. Shutoff valve “open” position C. To range
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:
Natural gas: Minimum pressure: 6" WCP
Maximum pressure: 14" WCP
LP gas: Minimum pressure: 12" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet pressure.
†®TEFLON is a registered trademark of Chemours.
IMPORTANT:
instructions in the “Level Range” section of the Owner's Manual. Using the cooktop as a reference for leveling the range is not
Range must be level after installation. Follow the
recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
Type of Gas
Natural gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section of the Owner's Manual. The model/serial rating plate located behind the
gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specifi model/serial rating plate for use with a different gas without consulting
the serving gas supplier. See “Gas Conversions” section of the Owner's Manual.
control panel has information on the types of
ed on the
Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W11508844A
04/19/2021
Page 2 of 2
ELECTRICAL REQUIREMENTS
IMPORTANT: The range must be electrically grounded in accordance
with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
■ A 120-volt, 60-Hz., AC-only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
■ Electronic ignition systems operate within wide voltage limits, but
proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
B
C
A
E
D
F
M
H
G
I
L
J
K
A. 18" (45.7 cm) upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see NOTE*. E. 30" (76.2 cm) min. opening width F. 3" (7.6 cm) min. clearance from both sides of range to side
wall or other combustible material.
G. The shaded area is recommended for installation of rigid
gas pipe and grounded outlet.
H. 131/8" (33.3 cm) I. 711/16" (19.5 cm) J. 413/16" (12.2 cm) K. 311/16" (9.4 cm) or measurement of N, whichever is greater L. 12" (30.5 cm) M. Cabinet door or hinges should not extend into the cutout.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by not less than
1
/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.