A
1" (25 mm) 1" (25 mm)
B 27" (686 mm) 27" (686 mm)
C 1" (25 mm) 1" (25 mm)
D* 1" (25 mm) 1" (25 mm)
E 32
9
/16" (686 mm) 31 1/2" (800 mm)
F** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed
NOTE: Some
models are not recommended for recessed or closet
installation.
A*
B C**
(460 mm)
Side view
Closet door with vents
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A*
1" (25 mm) 1" (25 mm)
B 32
9
/16" (686 mm) 31 1/2" (800 mm)
C** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
PRODUCT MODEL NUMBERS
ELECTRICAL
WED9200S WED9300V WED9400S
WED9400V WED9500T WED9600T
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10224585
11-07-08
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
This dryer requires a three- or four-wire, single­phase, 120/240-volt, 60-Hz, AC-only electrical supply (or three- or four-wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Do not use an extension cord.
Electric Dryer
Page 1 of 3
®
PRODUCT DIMENSIONS
EXHAUST VENTING
Exhaust your dryer to the outside. 4" (10.2 cm) diameter heavy metal exhaust vent and clamps are required. Rigid or flexible heavy metal exhaust vent must be used. The total length of flexible metal vent should not exceed 7-3/4 ft. (2.4 m). Do not use plastic or metal foil vent. Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust.
Closet installation – Dryer only
Recessed or loset installation – Dryer on pedestal
A
B
C
D
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A
38" (9652 mm) 38" (9652 mm)
B 32
9
/16" (686 mm) 31 1/2" (800 mm)
C 27" (686 mm) 27" (686 mm)
D 52
9
/16" (1335 mm) 51 1/2" (1308 mm)