Whirlpool WED71HEBW, WED80HEBC, WED94HEAC0 Dimension Guide

Electric Dryer
PRODUCT MODEL NUMBERS
WED70HEB, WED71HEB, WED80HEB, WED86HEB, WED88HEA, WED94HEA, WED96HEA
Front view:
383/4" Min.
(984 mm)
39" Max.
(990 mm)
Back view:
NOTE: Most
installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
27"
(686 mm)
Power supply
cord/cable
Water inlets (steam models
Vent
only)
61/2"
(165 mm)
(759 mm)
3
/2"*
(89 mm)
29
/8"*
Side view:
Recommended installation clearances (dryer only):
3"
18" min.
(457 mm)
(76 mm)
48 in.2 min.
(310 cm
2
)
6
/4"*
(18 mm)
* Approx. measurement.
14
/8"
(365 mm)
Installation spacing for recessed area or closet installation
/8"*
(156 mm)
*
5"
(127 mm)
(76 mm)
1"
*
(25 mm)
1"
(25 mm)
* 0" (0 mm) spacing is allowed.
3"
All dimensions show recommended and minimum spacing allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, oor moldings, and dryer venting.
■ Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
24 in.2 min.
(155 cm2)
W10573709B
10/2013
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
The Vent System Chart provides venting requirements that will help achieve best drying performance.
Standard Vent System Chart
Number of 90° elbows
0
Type
of vent
Rigid metal
Angled
hoods
64 ft. (20 m)
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
1
2
3
4
Rigid metal
Rigid metal
Rigid metal
Rigid metal
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Long Vent System Chart*
Number of 90° elbows
0
1
2
3
4
*For Model WED71HEB only; for all other models, refer to the Standard Vent System Chart above. To nd your model number, refer to the model and serial number plate in the inner door well.
NOTE: For long vent systems, use of box/louvered hoods will improve venting regardless of length.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Angled
hoods
160 ft. (48.8 m)
150 ft. (45.7 m)
140 ft. (42.7 m)
130 ft. (39.6 m)
120 ft. (36.6 m)
Determine vent length and elbows needed for best drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in Vent System Chart. Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Loading...