Whirlpool WED6600WL User Manual

®
4"
(102 mm)
Louvered style
Angled style
4"
(102 mm)
4"
(102 mm)
Box hood style
21/2"
(64 mm)
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
Number of 90 turns or elbows
Type of vent
Box or Louvered hoods
Angled hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5m)
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
29"
(737 mm)
221/4"
(565 mm)
291/4"
(743 mm)
43
1
/2"
(1105 mm)
14" max.* (356 mm)
A
B
C
29"
(737 mm)
5"
(127 mm)
1"
(25 mm)
1"
(25 mm)
1
8"*
(457 mm)
3"*
(76 mm)
3"*
(76 mm)
29
1
/4"
(743 mm)
48"2*
(
310 cm
2
)
24"
2
*
(155 cm2)
Electric Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
WED6600W
Electrical: A four-wire or three-wire, single phase, 120-volt, 60 Hz, AC-only, electrical supply is required on a separate 15 or 20 amp circuit,
used on both sides of the line. A time-delay fuse
f or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used.
o Not use plastic or metal foil vent. Exhaust outlet
D hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
RECESSED AREA AND CLOSET INSTALLATION
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
EXHAUST VENTING
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10164159B
07/2009
Loading...