Whirlpool WED5550X, WED5600X, WED5500X, WED5700X User Manual

27" Electric Dryer
4" (102 mm)
4" (102 mm)
B
A
4"
(102 mm)
2½"
C
Recommended styles: A. Louvered hood B. Box hood
Acceptable styles: C. Angled hood
Number 90º elbows
Ty pe of ventBox /louvered
hoods
Angled hoods
0Rigid metal 64 ft. (20 m) 58ft. (17.7 m)
1Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
2Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
3Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
43"
(1092 mm)
*291/2"
(749 mm)
27"
(687 mm)
A
23¾"
(603 mm)
43"
(1092 mm)
*291/2"
(749 mm)
27"
(687 mm)
B
13¾"
(349 mm)
A. Large opening side-swing door B. Wide opening hamper door
A
B
C
18"* (457 mm)
1" (25 mm)
27"
(686 mm)
1" (25 mm)
1"* (25 mm)
14" max.* (356 mm)
29 ¼"
(743 mm)
5 ½"*
(140 mm)
48 in.
(310 cm )
2
*
2
24 in.
(155 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
A. Recessed area
C. Closet door with vents
*Additional spacing recommended
PRODUCT MODEL NUMBERS WED5500X, WED5550X,
WED5600X, WED5700X
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time­delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Exhaust hood styles:
OVERALL DIMENSIONS
Dryer dimensions
* Most intallations require a minimum 5
the exhaust vent with elbow. See "Venting Requirements" in the Use and Care Guide.
Minimum required spacing
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
1
/
" (140 mm) clearance behind the dryer for
2
Vent System Chart:
NOTE: Side and bottom exhaust installations have a 90°
turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Do not use vent runs longer than specied in vent length chart. Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Ref. W10096988
04/2010
Loading...