Dryer Dimensions
Electric Dryer
PRODUCT MODEL NUMBERS
WED4800B, WED4810B, WED4850B, WED4870B, WED5000D,
WED4810E, WED4815E, WED4915E, WED4975E, WED4616F,
WED4916F
Wide opening side-swing door
Wide opening hamper door
(737 mm)
433/8"
(1102 mm)
1
/2"
(13 mm)
29"
(737 mm)
433/8"
(1102 mm)
11/2"
(38 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height
of 3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height
of 3.8 cu. ft. capacity washer).
Minimum spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, and
oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
■ Companion appliance spacing should also be considered.
133/4"
223/4"
(578 mm)
273/4"
(705 mm)
273/4"
(705 mm)
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Minimum Required Spacing
3"*
(76 mm)
3"*
(76 mm)
18"*
(457 mm)
1"
(25 mm)
14" max.*
(356 mm)
29"
(737 mm)
1"
(25 mm)
A. Recessed area
B. Side view - closet or conned area
C. Closet door with vents
1"*
(25 mm)
27¾"
(705 mm)
2
48 in.
(310 cm )
24 in.
(155 cm )
*
2
2
*
2
*Additional spacing recommended
W10562358A
05/2015
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
0
1
2
3
4
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Vent System Chart
(Long Vent Models Only)
Number of
90° turns
or elbows
0 Rigid metal 120 ft. (36.6 m)
1
2
3
4
5 70 ft. (21.3 m)Rigid metal
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered, or
Angled hoods
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.