Whirlpool W10151493B, W10151492B User Manual

®
CABRIO™ FABRIC CARE
SYSTEM ELECTRIC
DRYER
Use & Care Guide
For questions about features, operation/performance,
parts, accessories, or service call: 1-800-253-1301
www.whirlpool.com or www.whirlpool.ca
or visit our website at
SÉCHEUSE
ÉLECTRIQUE CABRIO
AVEC SYSTÈME DE
SOIN DES TISSUS
Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composez le :
Para obtener acceso al manual de uso y cuidado en
español, o para obtener información adicional acerca
de su producto, visite: www.whirlpool.com.
Tenga listo su número de modelo completo. Puede
encontrar el número de modelo y de serie dentro de la
cavidad superior de la puerta.
Table of Contents/Table des matières ................. 2
1-800-807-6777
ou visitez notre site internet à
www.whirlpool.ca
W10151492B SP PN W10151493B
TABLE OF CONTENTS
TABLE DES MATIÈRES
DRYER SAFETY..............................................................................2
INSTALLATION INSTRUCTIONS..................................................4
Tools and Parts............................................................................4
Location Requirements ...............................................................4
Electrical Requirements - U.S.A. Only.........................................5
Electrical Requirements - Canada Only.......................................6
Electrical Connection - U.S.A. Only.............................................7
Venting Requirements................................................................12
Plan Vent System.......................................................................13
Install Vent System.....................................................................14
Install Leveling Legs...................................................................14
Connect Vent..............................................................................14
Level Dryer .................................................................................14
Reverse Door Swing ..................................................................15
Complete Installation
DRYER USE ..................................................................................17
Starting Your Dryer.....................................................................17
Stopping, Pausing, or Restarting...............................................18
Drying and Cycle Tips................................................................18
Status Lights ..............................................................................18
Cycles.........................................................................................19
Modifiers.....................................................................................20
Options.......................................................................................20
End of Cycle Signal....................................................................21
Changing Cycles, Modifiers, and Options.................................21
Drying Rack Option....................................................................21
DRYER CARE ...............................................................................22
Cleaning the Dryer Location ......................................................22
Cleaning the Lint Screen.....................
Cleaning the Dryer Interior .........................................................22
Removing Accumulated Lint......................................................22
Vacation and Moving Care.........................................................22
Changing the Drum Light...........................................................23
TROUBLESHOOTING ..................................................................23
ASSISTANCE OR SERVICE.........................................................25
ACCESSORIES .............................................................................25
WARRANTY ..................................................................................26
.................................................................16
.......................................22
SÉCURITÉ DE LA SÉCHEUSE ....................................................27
INSTRUCTIONS D’INSTALLATION.............................................29
Outillage et pièces......................................................................29
Exigences d’emplacement.........................................................29
Spécifications électriques - Pour le Canada seulement............30
Exigences concernant l'évacuation...........................................30
Planification du système d’évacuation......................................32
Installation du système d’évacuation.........................................33
Installation des pieds de nivellement.........................................33
Raccordement du
Réglage de l'aplomb de la sécheuse.........................................33
Inversion du sens d'ouverture de la porte .................................34
Achever l'installation ..................................................................35
UTILISATION DE LA SÉCHEUSE................................................36
Mise en marche de la sécheuse ................................................36
Arrêt, pause ou remise en marche.............................................37
Conseils pour le séchage et les programmes ...........................37
Témoins lumineux ......................................................................38
Programmes...............................................................................38
Modificateurs..............................................................................39
Options.......................................................................................40
Signal d
Changement des programmes, modificateurs et options.........41
Option de grille de séchage .......................................................41
ENTRETIEN DE LA SÉCHEUSE..................................................42
Nettoyage de l'emplacement de la sécheuse ...........................42
Nettoyage du filtre à charpie......................................................42
Nettoyage de l’intérieur de la sécheuse.....................................43
Retrait de la charpie accumulée ................................................43
Précautions à prendre pour les vacances et avant un
déménagement ..........................................................................43
Changement de l’ampoule
DÉPANNAGE.................................................................................44
ASSISTANCE OU SERVICE.........................................................46
ACCESSOIRES .............................................................................46
GARANTIE.....................................................................................47
e fin de programme.......................................................40
conduit d’évacuation ...................................33
d’éclairage du tambour..................43
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
2
follow instructions.
You
can be killed or seriously injured if you don't
instructions.
follow
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
including the following:
Read all instructions before using the dryer. Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry­cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
Before the dryer is removed from service or discarded, remove the door to the drying compartment.
Do not reach into the dryer if the drum is moving. Do not install or store the dryer where it will be exposed
to the weather. Do not tamper with controls.
To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
SAVE THESE INSTRUCTIONS
Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
Clean lint screen before or after each load. Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
See installation instructions for grounding requirements.
3
INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Flat-blade screwdriver #2 Phillips screwdriver Adjustable wrench that
opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)
Wire stripper (direct wire installations)
Parts supplied:
Remove parts package from dryer drum. Check that all parts were included.
4 leveling legs
Parts needed:
Check local codes. Check existing electrical supply and venting and see “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal ex available for purchase from the dealer from whom you purchased your dryer. For information on ordering, please refer to the “Assistance or Service” section. You may also contact the dealer from whom you purchased your dryer.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
Tin snips (new vent installations)
Level Vent clamps Caulking gun and
compound (for installing new exhaust vent)
Tape measure
haust system hardware
Location Requirements
You will need
A location that allows for proper exhaust installation. See “Venting Requirements.”
A separate 30-amp circuit. If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
quarters. Contact your local building inspector.
43½"
(1105 mm)
22¼"
*29¼"
(743 mm)
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
29"
(737 mm)
(565 mm)
4
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered. Additional spacing is required if you exhaust out the rear of
the dryer to either the right or left side.
3"* (76 mm)
3"* (76 mm)
18"* (457 mm)
1" (25 mm)
29" (737 mm)
A
14" max.* (356 mm)
1"
1"*
29¼"
(25 mm)
(25 mm)
(743 mm)
5" (127 mm)
B
A. Recessed area
de view - closet or confined area
B. Si C. Closet door with vents
48 in. * (310 cm )
24 in. * (155 cm )
2
2
2
2
C
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA­Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutra secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” in “Electrical Connection - U.S.A. Only” section.
A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use wi clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
If your outlet looks like this:
l ground conductor is
th
,
Electrical Requirements - U.S.A. Only
It is your responsibility
To contact a qualified electrical installer. To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
5
If your outlet looks like this:
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum).
At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
WARNING:
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Improper connection of the equipment-
SAVE THESE INSTRUCTIONS
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard Plug into a grounded 4 prong outlet. Failure to do so can result in death or electrical shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.
4-wire receptacle 14-30R
Do not use an extension cord.
If you are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 3394208. For further information, please reference the service numbers located in the “Assistance or Service” section.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
6
Electrical Connection - U.S.A. Only
E
A
Power Supply Cord Direct Wire
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
B
A
D
C
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
3. Install strain relief. Style 1: Power supply cord strain relief
Remove the screws from a " (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.
3
4
A. Terminal block cover B. Hold-down screw C. External ground conductor screw D. Center, silver-colored terminal block screw E. Neutral ground wire
F. Hole below terminal block opening
F
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down
B
C D
7
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
Electrical Connection Options
If your home has: And you will be
connecting to:
4-wire receptacle (NEMA type 14-30R)
A UL listed, 120/240-volt minimum, 30-amp, dryer power supply cord*
Go to Section:
4-wire connection: Power Supply Cord
Style 2: Direct wire strain relief
Unscrew the removable conduit connector and any screws
3
from a " (19 mm) UL listed strain relief (UL marking on strain
4 relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.
A
B
C
A. Removable conduit connector B. Hole below terminal block opening C. Strain relief threads
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
4-wire direct A fused
disconnect or circuit breaker
5"
(127 mm)
3-wire receptacle (NEMA type 10-30R)
box*
A UL listed, 120/240-volt minimum,
4-wire connection: Direct Wire
3-wire connection: Power Supply Cord
30-amp, dryer power supply cord*
3-wire direct A fused
disconnect or circuit
1
2
3 "
(89 mm)
box*
breaker
3-wire connection: Direct Wire
*If local codes do not permit the connection of a cabinet-ground
conductor to the
neutral wire, go to “Optional 3-wire
connection” section.
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
B
A
D
C
A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug C. Ground prong D. Neutral prong E. Spade terminals with upturned ends
3
4
F. " (19 mm) UL listed strain relief
G. Ring terminals
E
F
G
4. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
8
1. Remove center silver-colored terminal block screw.
C
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
“Venting Requirements.”
B
C
D
A
A. Neutral ground wire B. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw. C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾" (19 mm) UL listed strain relief
E
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3 wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 1 " (38 mm) from 3 remaining wires. Strip insulation back 1" (25 mm). Shape ends of wires into a hook shape.
When connecting
to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1
1"
(25 mm)
5"
(127 mm)
2
A
E
B
C
F
D
A. External ground conductor screw
B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. ¾" (19 mm) UL listed strain relief
enter silver-colored terminal block screw
E. C
F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws.
Tighten
screws.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the
nal block. Squeeze hooked ends together. Tighten
termi screw.
B
D
A
E
A. Neutral ground wire B. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire) E. ¾" (19 mm) UL listed strain relief
9
3. Connect ground wire (green or bare) of direct wire cable to
E
C
external ground conductor screw. Tighten screw.
A
B
1. Loosen or remove center silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
A
C
F
D
A. External ground conductor screw
B. Neutral ground wire C. Ground wire (green D. ¾" (19 mm) UL listed strain relief
E. Center silver-colored terminal block screw
F. Neutral wire (white or center wire)
or bare) of power supply cord
4. Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
ing Requirements.”
“Vent
B
D
E
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
¾
E. " (19 mm) UL listed strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slo
t of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
“Venting Requirements.”
3-wire connection: Direct Wire
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
B
D
E
A
C
A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends
¾
E. " (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral wire (white or center wire)
F
G
10
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
1
Strip 3 " (89 mm) of outer covering from end of cable. Strip
2 insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.
1"
(25 mm)
1
2
3 "
(89 mm)
When connecting to the terminal block, place the hooked end of
E
C
D
the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1. Loosen or remove center silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.
A
B
A
C
B
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
3
4
E. " (19 mm) UL listed strain relief
3. Place the hooked ends
of the other direct wire cable wires
D
under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
“Venting Requirements.”
E
F
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
3
E. " (19 mm) UL listed strain relief
4
F. Grounding path determined by a qualified electrician
3. Connect the other wires to outer termina
l block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external
ground conductor screw to an adequate ground.
11
Venting Requirements
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death or fire.
Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings, or floors.
The total length of flexible metal vent should not exceed
3
4 ft (2.4 m).
7
Elbows
45° elbows provide better airflow than 90° elbows.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance. Only rigid or flexible metal vent shall be used for exhausting.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent. 4" (102 mm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
Good Better
Clamps
Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the duct and catch lint. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
B
A
4"
(102 mm)
4" (102 mm)
A. Louvered hood style B. Box hood style
4"
102 mm
4" (102 mm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section.
Rigid metal vent
For best drying performance, rigid metal vents are recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for cleaning.
Flexible metal vent must be fully extended and supported when the dryer is in its final location.
12
The angled hood style (shown here) is acceptable.
4"
(102 mm)
2½"
(64 mm)
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
G
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
B
C
D
A
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet
Standard exhaust installation with rigid metal or flexible metal vent
E
F
B
H
NOTE: The following kits for close clearance al installations are available for purchase. Please see the “Assistance or Service” section to order.
Over-the-Top Installation: Part Number 4396028 Periscope Installation (For use with dryer vent to wall vent
mismatch): Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch Part Number 4396011 - 18" (457 mm) to 29" (737 mm)
mismatch Part Number 4396014 - 29" (737 mm) to 50" (1.27 m)
mismatch Rear exhaust installation to left or right side: Part Number 8212504
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
ternate
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.
A
A. Over-the-top installation (also available with one
offset elbow) B. Periscope installation C. Rear exhaust installation to left or right side
B
C
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying performance
Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
Shorten the life of the dryer. Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying performance.
13
Vent system chart
NOTE: Performance of rear exhaust to either side of the dryer is
equivalent to adding one elbow. To determine maximum exhaust length, add one elbow to the chart.
Number of 90º turns or elbows
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Type of vent
Box or Louvered hoods
Angled hoods
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into the interior of the vent to secure the vent, because they can catch lint.
Install Leveling Legs
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond ma visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.
rking is no longer
Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible
gas line.
. Once the exhaust vent connection is made, remove the
4
corner posts and cardboard.
Level Dryer
Check the levelness of the dryer by first placing a level on the top of the dryer near the console.
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large, flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge of the dryer.
2. Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard. See illustration.
Then, by placing a level in the crease on the side of the dryer between the top of the dryer and the dryer cabinet, check the levelness from front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.
14
Reverse Door Swing
B
You can change your door swing from a right-side opening to a left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space
to protect the surface.
Remove the door assembly
1. Open the dryer door.
2. Remove the bottom screw from each of the 2 hinges that
attach the dryer door to the front panel of the dryer.
3. Loosen the top screw from each of the 2 hinges in Step 2.
A
B
A
B
A. Loosen these screws. B. Remove these screws.
Reverse the strike
1. Remove the door strike from the dryer door opening.
2. Remove the cosmetic screw opposite the door strike.
A
A. Door strike B. Cosmetic screw
3. Reinstall the door strike and cosmetic screw on the opposite
side of the dryer door opening from where they were removed. NOTE: Door strike and plugs must be on the same side of the dryer door opening.
Reinstall the door
1. Remove the 4 screws and 2 hinges from the dryer door.
2. Replace the 4 screws in the same holes.
4. Remove the dryer door and the hinges by lifting upward on
the door. Lay the door on a flat, protected surface, with the inside of the door facing up. Remove remaining 2 loose screws from dryer front panel.
5. Remove the 4 plastic plugs located outside the dryer door
opening.
6. Install 4 plastic plugs into screw holes in the dryer left where
the hinges were removed in Step 4.
3. Remove the 4 screws from the opposite side of the door.
15
Loading...
+ 33 hidden pages