Date of purchase: _________________________________
Date of installation: _______________________________
Installer: ________________________________________
Model number: ___________________________________
Serial number: ___________________________________
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ....................................... 23
Date d’achat : _____________________________________
Date d’installation : ________________________________
Installateur : ______________________________________
Numéro de modèle : ________________________________
Numéro de série : __________________________________
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Flat-blade screwdriver#2 Phillips screwdriver
1/4" nut driver or socket
wrench (recommended)
Tape measure
Tin snips (new vent
installations)
Vent clamps
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Utility knife
Caulking gun and compound
(for installing new exhaust vent)
Putty knife
Tools needed for gas installations:
8" or 10" pipe wrench
8" or 10" adjustable wrench
(for gas connections)
Level
4
Pipe-joint compound
resistant to LP gas
Pliers
Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
Optional Equipment: (Not supplied with dryer)
Refer to your “Use and Care Guide” for information about
accessories available for your dryer.
Location Requirements
If you are using power supply cord, a grounded electrical ■
outlet located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
A sturdy oor to support dryer and a total weight (dryer ■
and load) of 200 lbs. (90.7 kg). The combined weight of a
companion appliance should also be considered.
Level oor with maximum slope of 1" (25 mm) under entire ■
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C).
At lower temperatures, the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
You will need:
A location allowing for proper exhaust installation. ■
See “Venting Requirements.”
A separate 30 amp circuit for electric dryers.■
A separate 15 or 20 amp circuit for gas dryers.■
5
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356 mm)
27¾"
(705 mm)
48 in.
(310 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
24 in.
(155 cm )
2
*
2
Installation clearances:
43"
(1092 mm)
*291/2"
(749 mm)
27"
(687 mm)
A
23¾"
(603 mm)
43"
(1092 mm)
27"
(687 mm)
*291/2"
(749 mm)
13¾"
(349 mm)
B
A
B
C
18"*
(457 mm)
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356 mm)
29
¼"
(743 mm)
5½"*
(140 mm)
48 in.
(310 cm )
2
*
2
24 in.
(155 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
29" Wide Models
Dryer Dimensions
27" Wide Models
Dryer Dimensions
A. Large opening side-swing door
B. Wide opening hamper door
Installation Spacing
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
Installation Spacing
A. Recessed area
B. Side view – closet or conned area
C. Closet door with vents
*Required spacing
Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or the Canadian Manufactured
Home Standard CAN/CSA-Z240 MH.
6
A. Recessed area
B. Side view – closet or conned area
C. Closet door with vents
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of ■
installation and servicing.
Additional clearances might be required for wall, door, and ■
oor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is ■
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation ■
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.■
Metal exhaust system hardware, available for purchase. ■
For further information, please reference the “Assistance or
Service” section of the “Dryer User Instructions.”
Special provisions must be made in mobile homes to ■
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
�
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
ELECTRIC DRYER POWER
HOOKUP – CANADA ONLY
Electrical Requirements
It is your responsibility:
To contact a qualied electrical installer.■
To be sure that the electrical connection is adequate ■
and in conformance with the Canadian Electrical Code,
C22.1-latest edition and all local codes. A copy of the
above codes standard may be obtained from: Canadian
Standards Association, 178 Rexdale Blvd., Toronto, ON
M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt, ■
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA International Certied ■
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure
wall receptacle is within reach of dryer’s nal location.
Install Leveling Legs
1.
Prepare dryer for leveling legs
4-wire receptacle (14-30R)
Do not use an extension cord.■
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 8579325.
For further information, please reference the “Assistance or
Service” section of the “Dryer User Instructions.”
To avoid damaging oor, use a large at piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
7
A
B
E
D
C
2.
diamond
m
arking
Screw in leveling legs
Examine leveling legs and nd diamond marking. Screw legs
into leg holes by hand. Use a wrench to nish turning legs
until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its nal location. Leave enough room to connect the
exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the oor.
Mobile home installations require a Mobile Home Installation
Hold-down Kit. For ordering information please reference the
“Dryer User Instructions.”
GAS DRYER POWER
HOOKUP
Gas Supply Requirements
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is designcertied by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas ■
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, please reference
the “Assistance or Service” section of the “Dryer User
Instructions.”
LP gas conversion:
Conversion must be made by a qualied technician.
No attempt shall be made to convert the dryer from the gas
specied on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.
Gas supply line
1/2" NPT pipe is recommended.■
3/8" approved tubing is acceptable for lengths under ■
20 ft. (6.1 m) if local codes and gas supplier permit.
Must include 1/8" NPT minimum plugged tapping accessible ■
for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
Must include a shut-off valve:■
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) feet (1.8 m)
of the dryer.
The shut-off valve location should be easy to reach for opening
and closing.
A. 3/8" exible gas connector
B. 3/8" pipe to are adapter tting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be
8
connected to the gas supply. Listed here are some guidelines
for two different methods of connection.
This dryer must be connected to the gas supply line with a
listed exible gas connector that complies with the standard for
connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
�
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a qualied electrician.
Option 1 (Recommended Method)
A
1¼"
(32 mm)
9¼"
(235 mm)
A
*5 3/4"
(159 mm)
1
1
/2"
(38 mm)
Flexible stainless steel gas connector:
If local codes permit, use a new exible stainless steel gas ■
connector (Design Certied by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" are x 3/8" NPT adapter
tting between the stainless steel gas connector and the
dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing ■
(if codes and gas supplier permit).
If you are using Natural Gas, do not use copper tubing.■
3/8" are x 3/8" NPT adapter tting between dryer pipe and ■
3/8" approved tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and a ■
different size adapter tting.
If your dryer has been converted to use LP gas, 3/8" LP ■
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP
gas must be used. Do not use TEFLON®† tape.
Dryer gas pipe
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m) a 4% reduction ■
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping ■
system during pressure testing at pressures greater than
1/2 psi.
Electrical Requirements
The gas pipe that comes out through the rear of your dryer ■
has a 3/8" male pipe thread.
29" Wide Model
A. 3/8" NPT dryer pipe
27" Wide Model
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
The design of this dryer is certied by CSA International for ■
use at altitudes up to 10,000 ft. (3,048 m), above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A. 3/8" NPT dryer pipe
■120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
9
VENTING
4"
(102 mm)
Venting Requirements
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object ■
that may obstruct exhaust (such as owers, rocks, bushes,
or snow).
Recommended Styles:
Louvered hood Box hood
Acceptable Style:
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used for
exhausting.
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps ■
may be used.
Do not use plastic or metal foil vent.■
Rigid metal vent:
Recommended for best drying performance and to avoid ■
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in nal dryer location.■
Remove excess to avoid sagging and kinking that may result ■
in reduced airow and poor performance.
Do not install in enclosed walls, ceilings, or oors.■
The total length should not exceed 7■
3
/4 ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or exible metal vents. Review “Vent System Chart” and,
if necessary, modify existing vent system to achieve best drying
performance.
Angled hood
Elbows:
45° elbows provide better airow than 90° elbows.■
Good
Better
Clamps:
Use clamps to seal all joints.■
Exhaust vent must not be connected or secured with screws ■
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
10
See “Venting Kits” for more information.
Plan Vent System
B
B
C
D
E
F
G
H
I
A
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
Over-The-Top installation (also available with one offset elbow)
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or exible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
I. Optional side exhaust outlet
Optional exhaust installations:
27" Wide Models can be converted to exhaust out the right side,
left side, or through the bottom (4-way vent kit). Each kit includes
step-by-step instructions. For ordering information, see “Venting
Kits.”
NOTE: The following kits for close clearance alternate
Periscope installation
installations are available for purchase.
Venting Kits
For more information, call 1-800-901-2042, or visit us
at www.applianceaccessories.com. In Canada, call
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP0–5" Metal vent periscope
4396037RP0"–18" Metal vent periscope
4396011RP18"–29" Metal vent periscope
439601429"–50" Metal vent periscope
4392892In-Wall metal DuraVent™ Periscope
W101865964-way vent kit – universal grey (27" Dryers Only)
4396028Sure Connect™ venting kit
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
The “Vent System Chart” provides venting requirements that
will help achieve best drying performance.
Vent System Chart
Determine vent path:
Select route that will provide straightest and most direct path ■
outdoors.
Plan installation to use fewest number of elbows and turns.■
When using elbows or making turns, allow as much room ■
as possible.
Bend vent gradually to avoid kinking.■
Use as few 90° turns as possible.■
Determine vent length and elbows needed for best
drying performance:
Use following “Vent System Chart” to determine type of vent ■
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in “Vent System Chart.” Exhaust systems longer than those
specied will:
Shorten life of dryer.■
Reduce performance, resulting in longer drying times and ■
increased energy usage.
Number of
90° turns or
elbows
0
1
2
3
4
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Vent System Chart
(29" Wide Long Vent Models Only)
Number of
90° turns
or elbows
0Rigid metal120 ft. (36.6 m)
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered, or
Angled hoods
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
12
570 ft. (21.3 m)Rigid metal
Install Vent System
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
A
B
C
D
Connect vent to exhaust hood
A
B
A
B
2.
Vent must t over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
Make Gas Connection
Connect gas supply to dryer
1.
Open shut-off valve
3.
Closed valve
Open valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
Connect Vent
1.
Connect vent to exhaust outlet
Flared
male tting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-ared male ttings. If exible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON®† tape.
2.
Plan pipe tting connection
Non-ared
male tting
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must t over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
Move dryer to nal location
2.
A. 3/8" exible gas connector
B. 3/8" dryer pipe
A combination of pipe ttings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-are adapter tting
Move dryer to nal location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.
13
Level Dryer
1.
Level dryer
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing system
to operate correctly.
If the dryer will not start, check the following:
Dryer is plugged into a grounded 3-prong outlet.■
Electrical supply is connected.■
Household fuse is intact and tight, or circuit breaker has ■
not tripped.
Dryer door is closed.■
When the dryer has been running for 5 minutes, open the
q
dryer door and feel for heat. If you feel heat, cancel cycle and
close the door.
If you do not feel heat, turn the dryer off and check to see
whether gas supply line shut-off valve is open.
If the gas supply line shut-off valve is closed, open it, ■
then repeat the 5-minute test as outlined above.
If the gas supply line shut-off valve is open, contact a ■
qualied technician.
NOTE: You may notice an odor when the dryer is rst heated.
This odor is common when the heating element is rst used.
The odor will go away.
Reverse Door Swing (Optional)
If your door is the 29" Large Side-Swing Door,
follow steps 1–6.
Not Level LEVEL Not Level
Tighten and adjust leveling legs
2.
If dryer is not level, prop up using a wood block. Use wrench
to adjust legs up or down, and check again for levelness.
Once legs are level, make sure all four legs are snug against
the oor before tightening them.
Complete Installation Checklist
Check that all parts are now installed. If there is an extra
q
part, go back through steps to see what was skipped.
Check that you have all of your tools.
q
Dispose of/recycle all packaging materials.
q
Check dryer’s nal location. Be sure vent is not crushed
q
or kinked.
Check that dryer is level. See “Level Dryer.”
q
Remove lm on console and any tape remaining on dryer.
q
Wipe dryer drum interior thoroughly with a damp cloth to
q
remove any dust.
Read “Dryer Use” in your “Use and Care Guide.”
q
Set the dryer on a full heat cycle (not an air cycle) for
q
20 minutes and start the dryer.
14
If your door is the 29" Super Wide Side-Swing Door,
follow steps 1–13.
If your door is the 27" Wide Side-Swing Door,
follow steps 1–11.
If your door is the 27" Wide Side-Swing Door with Glass,
follow steps 1–14.
NOTE: Magnetized screwdriver is helpful.
29" Wide Model Large Side-Swing Door
1.
Place towel on dryer
Place towel on top of dryer to avoid damaging the surface.
2.
Remove bottom screws
4.
Remove and transfer hinge
hole plugs
Use a small, at-blade screwdriver to gently remove 4 hinge
hole plugs on left side of dryer cabinet. Insert plugs into hinge
holes on opposite side of dryer cabinet.
5.
Insert screws in hinge holes on
dryer cabinet
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
3.
Lift door off top screws
Lift door until top screws in cabinet are in large part of hinge
slot. Pull door forward off screws. Set door on top of dryer.
Remove top screws from dryer cabinet.
NOTE: Two people maybe needed to reinstall door.
Insert screws into bottom holes on left side of dryer cabinet.
Tighten screws halfway. Position door so large end of door
hinge slot is over screws. Slide door up so screws are in
bottom of slots. Tighten screws. Insert and tighten top
screws in hinges.
6.
Check door strike alignment
Close door and check that door strike aligns with door
catch. If needed, slide door catch left or right within slot
to adjust alignment.
15