Whirlpool TGW 3573 IN INSTRUCTION FOR USE

4gb66010a.fm Page 1 Monday, April 28, 2003 3:31 PM
TGW 3571/TGW 3573 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids 2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Control knob for front
left burner
8. Control knob for rear, left burner
9. Control knob for central burner
10. Control knob for rear, right burner
11. Control knob for front right burner
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
setting.
At the same time, hold the knob down until the burner ignites.
After the burner has ignited, keep the knob pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Shaded circle
Large flame and star Small flame
The burner safety device shuts off the gas
supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The separator panel, positioned beneath
the cooktop at a minimum distance of 20 mm, must be sealed.
Tap closed Maximum opening/delivery
and electric ignition Minimum opening or
reduced delivery
A wooden shelf must be installed below the cooktop with a minimum thickness of 20 mm, at least 15 mm from the bottom of the surface itself.
5019 419 66010/A
4gb66010a.fm Page 2 Monday, April 28, 2003 3:31 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance "A" between the wall cabinets is between 600 mm and
680 mm, the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. Before installing a hood above the cooktop please refer to the hood instructions, which specify the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used Type of
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 5 gas 11 1048 22 G30 28-30 mbar 5 gas 11 799 22 G31 37 mbar 5 gas 11 785 22
burner
triple crown large medium small
triple crown large medium small
triple crown large medium small
Appliance model Total rated heat
Injector marking
63-121
129 101
77
37-90
87 66 50
37-90
87 66 50
Rated heat capacity Pcs-kW
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
capacity Pcs-kW
Rated consumptio n
333 l/h 286 l/h 167 l/h
95 l/h
254 g/h 218 g/h 127 g/h
73 g/h
250 g/h 214 g/h 125 g/h
71 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
1.50
0.80
0.50
0.50
1.50
0.80
0.50
0.50
1.50
0.80
0.50
0.50
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for burningm
3
/h
Loading...