4gb66010a.fm Page 1 Monday, April 28, 2003 3:31 PM
TGW 3571/TGW 3573 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Control knob for front
left burner
8. Control knob for rear,
left burner
9. Control knob for
central burner
10. Control knob for rear,
right burner
11. Control knob for front
right burner
Symbols
Operation of burners with
safety device and electric
ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting.
• At the same time, hold the knob down until
the burner ignites.
• After the burner has ignited, keep the
knob pressed down for about
10 seconds.
• Release the knob.
If the burner does not ignite, repeat the
operations described above.
Note:
— Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the
small flame setting .
Shaded
circle
Large flame
and star
Small
flame
— The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden
draught, an interruption in the gas
delivery, boiling over of liquids, etc.).
— The separator panel, positioned beneath
the cooktop at a minimum distance of
20 mm, must be sealed.
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
A wooden shelf must be installed below
the cooktop with a minimum thickness of
20 mm, at least 15 mm from the bottom of
the surface itself.
5019 419 66010/A
4gb66010a.fm Page 2 Monday, April 28, 2003 3:31 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance "A" between the wall cabinets is between 600 mm and
680 mm, the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width
of the cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood
instructions, which specify the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used Type of
NATURAL GAS
(Methane) G20
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Type of gas
used
G20 20 mbar 5 gas 11 1048 22
G30 28-30 mbar 5 gas 11 799 22
G31 37 mbar 5 gas 11 785 22
burner
triple crown
large
medium
small
triple crown
large
medium
small
triple crown
large
medium
small
Appliance model Total rated heat
Injector
marking
63-121
129
101
77
37-90
87
66
50
37-90
87
66
50
Rated
heat
capacity
Pcs-kW
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
capacity
Pcs-kW
Rated
consumptio
n
333 l/h
286 l/h
167 l/h
95 l/h
254 g/h
218 g/h
127 g/h
73 g/h
250 g/h
214 g/h
125 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
1.50
0.80
0.50
0.50
1.50
0.80
0.50
0.50
1.50
0.80
0.50
0.50
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burningm
3
/h