Whirlpool TGV 3570 IN INSTRUCTION FOR USE

4gb66002.fm5 Page 1 Wednesday, January 9, 2002 10:18 AM
TGV 3570 PRODUCT DESCRIPTION SHEET
IT
1. Removable panstand grids
2. Small burner
3. Large burners
4. Triple crown burner
5-6. Medium burners
7. Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded
circle
Large
flame
and star
Small
flame
Tap closed
Maximum opening/
delivery and electric
ignition
Minimum opening or
reduced delivery
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
setting .
At the same time, keep the knob pressed
against the control panel until the burner
ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the
operations described above.
5019 419 66002
Note:
- Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
- The safety device of the burner shuts off the
gas supply to the burner if its flame goes
out accidentally (because of a sudden gust
of wind, an interruption in the gas delivery,
the overflowing of liquids, etc).
4gb66002.fm5 Page 2 Wednesday, January 9, 2002 10:18 AM
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: if the distance A between the wall cabinets is between 600 mm and
680 mm, the height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of
the cooktop, the height B must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL
GAS
(Methane)G 20
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 5 gas 10.8 1029 l/h 21.6
G 30 28-30 mbar 5 gas 10.8 785 g/h 21.6
G 31 37 mbar 5 gas 10.8 769 g/h 21.6
Type of
burner
large
medium
small
triple crown
large
medium
small
triple crown
large
medium
small
triple crown
Appliance
model
Injector
marking
115
97
72
124
85
65
50
91
85
65
50
91
Total rated
heat capacity
Pcs-kW
Rated
heat
capacity
Pcs-kW
3.00
1.75
1.00
3.30
3.00
1.75
1.00
3,30
3.00
1.75
1.00
3.30
Rated
consump-
tion
286 l/h
167 l/h
95 l/h
315 l/h
218 g/h
127 g/h
73 g/h
240 g/h
214 g/h
124 g/h
71 g/h
236 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.75
0.44
0.30
1.5
0.75
0.44
0.30
1.5
0.75
0.44
0.30
1.5
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
/h
m