TGV 3420 PRODUCT DESCRIPTION SHEET
IT
1.
Removable panstand grids
3-5.
Medium burners
2-4.
Large burners
6.
Large burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Medium burner control knob
10.
Knob for large burner programmer
control
Symbols
Shaded circle Tap closed
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
• At the same time, keep the knob pressed against
the control panel until the burner ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Notes:
— Should particular local conditions of the delivered
gas make the ignition of the burner difficult, it is
advisable to repeat the operation with the knob
turned to the small flame setting .
— The safety device of the burner shuts off the gas
supply to the burner if its flame goes out
accidentally (because of a sudden gust of wind,
an interruption in the gas delivery, the
overflowing of liquids, etc.).
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
— cast iron griddles or terracotta pots and pans
— heat diffusers such as metal mesh, or any other
types
— two burners simultaneously for one receptacle
(e.g. fish kettle).
Large flame
and star
Small flame Minimum opening or
Maximum opening/delivery
and electric ignition
reduced delivery
Operation of programmer
On the large burner, the cooking time can be
programmed (up to 60 minutes)
• Light the large burner.
• Turn the programmer knob clockwise to the
desired cooking time.
• When the preset time is over, a warning bell rings,
the gas supply is shut off and the burner goes out.
• Turn the burner control knob to the shaded circle
position
.
Telescopic knobs
• A particular mechanism makes it possible to raise
the knobs about 1 cm, in order to clean the
surface under them. After cleaning, put the knobs
back in their original position.
Note:
Peel the plastic film off the metal knob insert.
5019 419 61331
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A“ between the wall cabinets is between 660 mm and 680
mm, the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of
the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL
GAS
(Methane) G 20
LIQUIFIED
PETROLEUM GAS
(Cylinder) G 30
LIQUIFIED
PETROLEUM GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 4 gas 9.30 886 l/h 18.6
G 30 28-30 mbar 4 gas 9.30 676 l/h 18.6
G 31 37 mbar 4 gas 9.30 664 l/h 18.6
Type of
burner
large
medium
large
medium
large
medium
Appliance
model
Injector
marking
128
94
85
65
85
65
Rated
heat
capacity
Pcs-kW
3.00
1.65
3.00
1.65
3.00
1.65
Total rated
heat capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
218 l/h
120 g/h
214 g/h
118 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.60
0.35
0.60
0.35
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
m
/h