TGV 3410/01 PRODUCT DESCRIPTION SHEET
NL
Removable panstand grids
1.
Large burner
2.
Medium burners
3-4.
Small burner
5.
Large burner control knob
6.
Medium burner control knob
7.
Medium burner control knob
8.
Small burner control knob
9.
Symbols
Shaded circle Tap closed
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
• At the same time, keep the knob pressed against
the control panel until the burner ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Notes:
— Should particular local conditions of the delivered
gas make the ignition of the burner difficult, it is
advisable to repeat the operation with the knob
turned to the small flame setting .
Large flame
and star
Small flame Minimum opening or
— The safety device of the burner shuts off the gas
supply to the burner if its flame goes out
accidentally (because of a sudden gust of wind,
an interruption in the gas delivery, the
overflowing of liquids, etc.).
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
— cast iron griddles or terracotta pots and pans
— heat diffusers such as metal mesh, or any other
types
— two burners simultaneously for one receptacle
(e.g. fish kettle).
Note:
Peel the plastic film off the metal knob insert.
Maximum opening/delivery
and electric ignition
reduced delivery
5019 419 61181
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: If the distance “A” between the wall cabinets is between 600 mm. and 680
mm. the height “B” must be a minimum of 520 mm. If the distance “A”
between the wall cabinets is greater than the width of the Cooktop, the height
“B” must be a minimum of 400 mm.
INJECTORS TABLE CATEGORY I2L
Type of gas
used
NATURAL
GAS G 25
Type of gas
used
G 25 25 mbar
Type of
burner
large
medium
small
Injector
marking
129
108
78
Appliance
model
4 gas 7.80 863 l/h 15.6
Rated
heat
capacity
Pcs-kW
3.00
1.90
1.00
Total rated
heat capacity
Pcs-kW
Rated
consumption
332 l/h
210 l/h
111 l/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.35
Gas pressure
min. rat. max.
20 25 30
Air required
for burning
3
/h
m