TGV 3405 PRODUCT DESCRIPTION SHEET
BE
1.
Removable panstand grids
2-3-5.
Medium burners
4.
Large burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Medium burner control knob
Symbols
Shaded circle Tap closed
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
• At the same time, keep the knob pressed against
the control panel until the burner ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Notes:
— Should particular local conditions of the delivered
gas make the ignition of the burner difficult, it is
advisable to repeat the operation with the knob
turned to the small flame setting .
— The safety device of the burner shuts off the gas
supply to the burner if its flame goes out
accidentally (because of a sudden gust of wind,
an interruption in the gas delivery, the
overflowing of liquids, etc.).
Large flame
and star
Small flame Minimum opening or
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
— cast iron griddles or terracotta pots and pans
— heat diffusers such as metal mesh, or any other
types
— two burners simultaneously for one receptacle
(e.g. fish kettle).
Maximum opening/delivery
and electric ignition
reduced delivery
Telescopic knobs
• A particular mechanism makes it possible to raise
the knobs about 1 cm, in order to clean the
surface under them.
After cleaning, put the knobs back in their original
position.
Note:
Peel the plastic film off the metal
knob insert.
5019 419 61321
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas
used
NATURAL
GAS
(Methane) G 20
NATURAL
GAS
(Groningue) G 25
LIQUIFIED
PETROLEUM GAS
(Cylinder) G 30
LIQUIFIED
PETROLEUM GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 4 gas 7.95 757 l/h 15.9
G 25 25 mbar 4 gas 7.37 818 l/h 14.7
G 30 28-30 mbar 4 gas 7.95 578 g/h 15.9
G 31 37 mbar 4 gas 7.95 568 g/h 15.9
Type of
burner
large
medium
large
medium
large
medium
large
medium
Appliance
model
Injector
marking
128
94
128
94
85
65
85
65
Rated
heat
capacity
Pcs-kW
3.00
1.65
2.78
1.53
3.00
1.65
3.00
1.65
Total rated heat
capacity Pcs-kW
Rated
consumption
286 l/h
157 l/h
308 l/h
170 l/h
218 g/h
120 g/h
214 g/h
118 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.85
0.52
0.85
0.52
0.85
0.52
0.85
0.52
Gas pressure
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for
burning m
3
/h