Whirlpool TGV 3402-1 IN PROGRAM CHART

TGV 3402 PRODUCT DESCRIPTION SHEET
BE
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed
Operation of burners with
electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Large flame and star
Small flame
Notes:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.)
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Telescopic knobs
A particular mechanism makes it possible to raise the knobs about 1 cm, in order to clean the surface under them. After cleaning, put the knobs back in their original position.
5019 419 61971
DIMENSIONS OF COOKING HOB AND WORKTOP
(mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II 2E+3+
Type of gas used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of burner
large medium small
large medium small
large medium small
large medium small
Injector marking 100/mm
128
94 76
128
94 76
85 65 50
85 65 50
Rated heat capacity kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
Rated consumption
286 l/h 157 l/h
95 l/h
308 l/h 170 l/h 103 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas Pressure mbar
min. rat. max.
17 20 25
20 20 30
20 28-30 35
25 37 45
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6 G25 25 mbar 4 gas 6.77 751 l/h 13.5 G30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G31 37 mbar 4 gas 7.30 521 g/h 14.6
Appliance model
Total rated heat capacity kW
Total rated consumption
ELECTRIC SUPPLY: 230V - 50Hz
Air required for burning
3
m
/h
Loading...