TGV 3402 PRODUCT DESCRIPTION SHEET
BE
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed
Operation of burners with
electric ignition
To light one of the burners:
• Press the relative knob and turn it
anti-clockwise to the large flame and
star setting .
• At the same time, keep the knob pressed
against the control panel until the burner
ignites.
• After the burner has ignited, keep the
knob pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the
operations described above.
Large flame
and star
Small flame
Notes:
— Should particular local conditions of the
delivered gas make the ignition of the
burner difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
— The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.)
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
Telescopic knobs
• A particular mechanism
makes it possible to
raise the knobs about
1 cm, in order to clean
the surface under
them. After cleaning,
put the knobs back in
their original position.
5019 419 61971
DIMENSIONS OF COOKING HOB AND WORKTOP
(mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II 2E+3+
Type of gas
used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Type of
burner
large
medium
small
large
medium
small
large
medium
small
large
medium
small
Injector
marking
100/mm
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat
capacity
kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
Rated
consumption
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reduced
heat
capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas Pressure mbar
min. rat. max.
17 20 25
20 20 30
20 28-30 35
25 37 45
Type of gas
used
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G25 25 mbar 4 gas 6.77 751 l/h 13.5
G30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G31 37 mbar 4 gas 7.30 521 g/h 14.6
Appliance
model
Total rated heat
capacity kW
Total rated
consumption
ELECTRIC SUPPLY: 230V - 50Hz
Air required for
burning
3
m
/h