[_ Product dimensions
Cabinet opening dimensions
[_ Before you start
j_ Electrical requirements
[_ Installation steps
If you need assistance:
Checkyour Use and Care Guide for a toHofree number to call or call
the dealer from whom you purchased this appUiance.ThedeaUeris
listed in the Yellow Pages of your phone directory under
"Appliances -- Household -- Major -- Service and Repair:'
Call when you:
[_ Have questions about range installation or operation.
[_ Need to obtain the name and number of an authorized service
company.
When you ca[[, you w[[[ need:
The range mode[ number:
[_ The range serial number:
Both numbers are listed on the model/serial rating plate, located on
the oven door or on the oven frame.
28=3/16"
cooktop
recessed width
__ 28=5/32" oven
30=3/4"
recessed
height
from
underside
of cooktop
to support
slats
recessed width
31-1/2"
cooktop
overaU
width
Yearsafetyand thesafetyofothersareveryimportant.
We haveprovided manyimportant safety messagesin this
24=13/32"
to back
manuaiand on your appliance.Always readand obey a[[
safety messages.
This isthe safety alert symbol
This symboi aierts you to potential hazardsthat can
kilI or hurt you and others.
Atisafety messageswiii foiiow the safetyatert symboi and
eitherthe word "DANGER"or "WARNING".Thesewords mean:
31=11/16"
overaU
height
J
You can be killedorseriouslyinjuredifyoudon'tfollow
instructions.
AII safety'messageswilI telI you what the p0tentiaihazardis,
tell you how to reducethe chance of h_jury,and tell you what
can happen if the instructions are not followed.
Countertop preparation:
Front edges:You may need to
shave or cut the trim of formed
or metal front-edged
countertops to dear the 30"
width of cooktop.
13" max. upper
For minimum
clearances to the
top of cooktop see
Note, _
wail
--7
25"countertop
floor
depth
24"lower
cabinet depth
\
cabinet
front
[
Side view of
cabinet cutout
*Note: 24" rain. when bottom of wood or
metal cabinet is protected by not less than
1/4" frame retardant miUboard covered
with not less than No. 28 MSG sheet steel
0,015" stainless steel &024" aluminum or
0.020" copper.
30" rain, clearance between the top of the
cooking platform and the bottom of an
unprotected wood or metal cabinet.
shipping
1=1/8"
max=
foot
if countertop thickness is
more than 1ol/2" inches
thick: Countertop must be
notched as shown to avoid
damaging the oven control
panel.
notch width _ /
to be equal _//
fi_ 1-1"1/2"
30=1/8"
Top of countertop
Note: countertop
must be [eve[
across front and
front to back.
%112" max.
countertop__
thickness
_----- 28=1/2" rain,
[f countertop extends more
1ol/8" beyond cabinet front:
Notch countertop as shown
to dear oven control pane[.
notch width
to be equal
both sides
Top view of
cabinet cutout
114"
radius both
corners
InstaU a 3=l/2"owide
support s_at on each
side, S_ats must be [eve[
front to back and with
each other.
opening width
recommended,
f ave ab e.
cabinet
front
30-3/4"
top of
countertop to
support slats
important: Observe all governing codes and
ordinances.
Proper installation is your responsibility. Have a qualified
technician instal[ this range.
Range location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Recessed installation area must provide complete enclosure
around the recessed portion of the range.
Electrical ground is required. See "Electrical requirements"
IMPORTANT.'Some cabinet and building materials are not
designed to withstand the heat produced by the oven for
baking and self-cleaning. Check with your builder or cabinet
supplier to make sure that the materials used wii[ not
discolor, delaminate or sustain other damage.
Range support surface MUST be solid, [eve[ and flush with
bottom of cabinet cutout.
Do not seal range to side cabinets.
When installing a cooktop under existing cabinets and the
installation does not meet the minimum cabinet clearances.
Install a range hood above the cooktop to avoid burn
hazards.
it is the customer's responsibility:
Tocontact a qualified electrical installer.
Toassure that the electrical installation is adequate and in
conformance with National Electrical Code,ANS[/NFPA
70 -- latest edition_% and air local codes and ordinances.
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety Standards,
Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD, Part
280); or when such standard is not applicable, the Standard
for Manufactured Homes Installations (Manufactured Home
Sites, Communities and Setups), ANSI A225.1/NFPA 501A,
or with local codes._
When this range is installed in mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
Four-wire power supply cane must be used in a mobile
home installation.The appliance wiring wiii need to be
revised. See four-wire electNcal connection, Page 3.
Tools needed:
Pds
river
Parts supplied:
_2 screws
Copies of the standards listed may be obtained from:
*_ National Fire Protection Association
8atterymarch Park
Quincy, Massachusetts 02269
Page 1
Locate electrical
supply junction
box on cutout
floor or on rear
waU (shown)
near floor line.
7/8" rain.
cutout and
cabinet door
Front view of
cabinet cutout
required
between
or hinge.
l
30=3/4"
top of 36" overaU
counter =
top to height
bottom
cuto;t
of cabinet l
countertop