PRODUCT MODEL SERIES
PRODUCT DIMENSIONS
GBD309PV
GBS309PV
RBD305PV
RBD307PV
RBS305PV
RBS307PV
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10192049B
09-05-08
30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
A. 28⁵⁄₁₆" (71.9 cm) max. recessed width
B. 29" (73.7 cm) max. overall height
C. 29³⁄₄" (75.6 cm) overall width
D. 23" (58.4 cm) max. recessed depth
E. 27¹⁄₂" (69.9 cm) recessed height
A. 28⁵⁄₁₆" (71.9 cm) max. recesse d width
B. 51" (129.5 cm) max. overall height
C. 29³⁄₄" (75.6 cm) overall width
D. 23" (58.4 cm) max. recessed depth
E. 49⁹⁄₁₆" (125.9 cm) recessed height
A
B
D
E
C
Single Oven Undercounter
(without cooktop installed above)
A. 30" (76.2 cm) min. cabinet width
B. 1¹⁄₂" (3.8 cm) min. top of cutout to
underside of countertop
C. 5¹⁄₄" (13.3 cm) bottom of cutout to floor
D. 28¹⁄₂" (72.4 cm) cutout width
E. 27³⁄₄" (70.5 cm) min. cutout height
A
B
C
D
E
Single Oven Installed in Cabinet
A. 30" (76.2 cm) min. cabinet width
B. 1" (2.5 cm) top of cutout to bottom
of upper cabinet door
C. 32" (81.3 cm) bottom o f cutout to floor
D. 28¹⁄₂" (72.4 cm) cutout width
E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to
top of cabinet door
F. 2 7³⁄₄" (70.5 cm) cutout height
A
B
D
E
F
C
tenibaC ni dellatsnI snevO elbuoD
A. 30" (76.2 cm) min. cabinet width
B. 1" (2.5 cm) top of cutout to bottom of
upper cabinet door
C. 14³⁄₄" (37.5 cm) bottom of cutout to floor
D. 28¹⁄₂" (72.4 cm) cutout width
E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to
top of cabinet door
F. 4 9³⁄₄" (126.4 cm) min. cutout height
A
B
C
D
E
F
nevO elbuoD ro elgniS
- weiV ediS tenibaC
A. 23¹⁄₄" (59.1 cm) min. cutout depth
B. 23" (58.4 cm) recessed oven depth
C. Oven front
D. Recessed oven
E. Cabinet
A
B
C
D
E
Electrical Requirements: Oven must be connected
to the proper electrical voltage and frequency as
specified on the model/serial number rating plate.
The model/serial number rating plate is located at
the bottom of the right-hand mounting rail. See the
following illustrations.
Models rated from 7.3 to 9.6 kW at 240 volts
(5.5 to 7.2 kW at 208 volts) require a separate
40-amp circuit. Models rated at 7.2 kW and below
at 240 volts (5.4 kW and below at 208 volts)
require a separate 30-amp circuit.
A circuit breaker is recommended. Connect directly
to the circuit breaker box (or fused disconnect)
through flexible, armored or nonmetallic, sheathed
copper cable (with grounding wire).
Flexible conduit from the oven should be
connected directly to the junction box. Do not cut
the conduit. The length of conduit provided is for
serviceability of the oven. A UL-listed or CSAapproved conduit connector must be provided.
If the house has aluminum wiring, follow the
procedure below:
1. Connect a section of solid copper wire to the
pigtail leads.
2. Connect the aluminum wiring to the added
section of copper wire using special connectors
and/or tools designed and UL-listed for joining
copper to aluminum.
Follow the electrical connector manufacturer's
recommended procedure. Aluminum/copper
connection must conform with local codes and
industry-accepted wiring practices.
A
A
Single Oven
. Model/serial number plate
Double Oven
A. Model/serial number plate
CUTOUT DIMENSIONS FOR OVENS INSTALLED UNDER COOKTOP
IMPORTANT: Observe all governing codes and ordinances. Cooktop must be approved for use over an oven. See Cooktop Installation
Instructions for cutout dimensions. Center the cooktop cutout over oven cutout.
To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor,
delaminate or sustain other damage. This oven has been designed in accordance with UL and CSA International and complies with the
maximum allowable wood cabinet temperatures of 194°F (90°C).
Approved Built-In Oven and Electric Cooktop Combinations
A
C
D
G
A. 24" (61 cm) cabinet depth
B. 25" (63.5 cm) countertop depth
C. Recommended oven and cooktop junction box locations
D. Allow ⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.
E. 27¾" (70.5 cm) minimum cutout height
F. 36" (91.4 cm) from cabinet base to countertop
G. 4⁵⁄₈" (11.7 cm) from floor
H. See Cutout Dimensions chart.
B
C
F
E
H
CUTOUT DIMENSIONS
Oven Size Oven Cutout Dimension
24" (61 cm) 22¹⁄₂" (57.2 cm)
27" (68.6 cm) 25¹⁄₂" (64.8 cm)
30" (76.2 cm) 28½" (72.4 cm)
36" (91.4 cm) 34¹⁄₂" (87.6 cm)
For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the
bottom of the cooktop burner box.
NOTE: For undercounter installation, it is recommended that the junction boxes for oven and cooktop be located in the adjacent right or
left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface
to pass the appliance cable through to the junction box. On models with Steam-Assist, it will be necessary to drill a ½" (1.3 cm)
minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing through to the undersink
water filter. If water supply tubing hole is drilled on the same side as the oven cable hole, a minimum of 2" (5.1 cm) is required between
the 2 holes.
W10373101A
Approved Built-In Oven and Induction Cooktop Combinations
A
C
C
B
F
D
E
G
H
A. 24" (61 cm) cabinet depth
B. 25" (63.5 cm) countertop depth
C. Recommended oven and cooktop junction box locations
D. Allow ⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.
E. 27¾" (70.5 cm) minimum cutout height
F. 36" (91.4 cm) from cabinet base to countertop
G. 3⁵⁄₈" (9.2 cm) from floor
H. See Cutout Dimensions chart.
CUTOUT DIMENSIONS
Oven Size Oven Cutout Dimension
24" (61 cm) 22¹⁄₂" (57.2 cm)
27" (68.6 cm) 25¹⁄₂" (64.8 cm)
30" (76.2 cm) 28½" (72.4 cm)
For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the
bottom of the cooktop burner box.
NOTE: For undercounter installation, it is recommended that the junction boxes for oven and cooktop be located in the adjacent right or
left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface
to pass the appliance cable through to the junction box. On models with Steam-Assist, it will be necessary to drill a 1" (1.3 cm)
minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing through to the undersink
water filter. If water supply tubing hole is drilled on the same side as the oven cable hole, a minimum of 2" (5.1 cm) is required between
the 2 holes.