Whirlpool PRB 350I A, PRB 380W A, WBE3411 W, WBE34132 A X, WBE34132 A WF PROGRAM CHART

...
AKF 617 PRODUCT DESCRIPTION SHEET
GB IT PT
3
1
4
5
1. Removable panstand grids
2. Auxiliary burner
3-4. Rapid burners
5-6. Semi-rapid burners
7. Auxiliary burner control knob
8. Rapid burner control knob
9. Rapid burner control knob
10. Semi-rapid burner control knob
11. Semi-rapid burner control knob
Symbols
2
8 9 10 11
7
6
Shaded circle tap closed
Large flame and star
Small flame
Maximum opening/ delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, hold the knob down until the burner ignites.
After the burner has ignited, keep the knob pressed down for about 10 seconds.
Release the knob.
If the burner fails to light, repeat the above steps.
5019 519 66010
Note: — Should particular local conditions of the
delivered gas make ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the cabinets is between 600 mm and 680 mm, the
height “B” must be a minimum of 520 mm. If the distance “A” between the cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. In case of installation of an oven under the cooktop, please refer to the separate oven instructions.
INJECTORS TABLE CATEGORY II2H3+
Ty p e o f gas used
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS (Cylinder) G30 LIQUID PETROLEUM GAS (Cylinder) G31
Type of gas used
Ty p e o f burner
Rapid Semi-rapid Auxiliary
Rapid Semi-rapid Auxiliary Rapid Semi-rapid Auxiliary
Appliance model 5 BURNERS
Injector marking
Rated thermal flow rate kW
129
3.00
101
1.75
77
1.00
87
3.00
66
1.75
50
1.00
87
3.00
66
1.75
50
1.00
Total rated heat capacity kW
Rated consumption
286 l/h 167 l/h
95 l/h 218 g/h 127 g/h
73 g/h
214 g/h 125 g/h
71 g/h
G20 20 mbar 5 gas 10.50 1000 l/h 21.0 G30 28-30 mbar 5 gas 10.50 764 g/h 21.0 G31 37 mbar 5 gas 10.50 750 g/h 21.0
Reduced heat capacity kW
0.80
0.50
0.50
0.80
0.50
0.50
0.80
0.50
0.50
Total rated consumption
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required (m
burning 1m
3
of gas
3
) for
ELECTRIC SUPPLY: 230 V~ 50 Hz
Loading...