Whirlpool Portable spa User Manual

www.clearcreekspas.com
The Quantum Plus
TM
Owner's Manual
www.clearcreekspas.com
www.clearcreekspas.com
IMPORTANT SAFETY INFORMATION
READ ALL INSTALLATION INSTRUCTIONS
Jacuzzi Whirlpool Bath does not recommend spa water temperatures in excess of 40°C (104°F). High water temperatures in excess of 40°C (104°F) and prolonged periods of use can raise the internal human body tempera­ture excessively and impair the body’s ability to regulate its internal temperature. Limit your initial use of the spa to 10-15 minutes. High body temperatures affect people differently; consult your physician about your safety and comfort before using the spa.
The elderly, the infirm, and children should not use the spa unattended. Infants should not be permitted in the spa at water temperatures over 38°C (100°F). Pregnant women and people with heart conditions should consult their phy­sicians before using the spa at water temperatures over 38°C (100°F).
Extra care should be taken when using the spa and con­suming alcoholic beverages. Alcohol, drugs, or certain medications such as tranquilizers affect a person’s ability to withstand high temperatures and may produce dangerous effects.
Keep body, hair, and clothing a minimum of 300mm (12 inches) away from suction fitting and skimmers at all times when the spa is operating. Hair longer than shoulder length should be secured close to the head, or a bathing cap should be worn. Do not remove the suction grilles! They are safety devices and must always be in place on the suction fitting to minimize the potential hazard of hair entanglement or body entrapment.
The wet surface of the spa is slippery. Use care when entering and exiting.
Save These Instructions for Future Use.
Owner's Record
Date Purchased
While the optional spa cover is rigid, it is not designed to support any weight. Therefore, as a safety precaution, do not sit, stand or lie on it.
The spa must be installed with adequate access and water drainage system. (See Installation Instructions.)
When using the electrical equipment, basic safety precautions should always be followed:
This unit is equipped with an earth leakage circuit breaker (ELCB) located in the electrical cabinet. Check at least once a month to be sure this is operational. (The procedure for testing is described on page 7 of this manual.)
Do not use electrically connected devices such as televi­sion, radio, or stereo speakers, lights, cooking devices, or telephones within 1.5m (5 feet) of the spa while the spa is being used. Lighting fixtures must not be located directly above or within 1.5m (5 feet) of the spa. If located with 3m (10 feet) of the spa, they must be on a circuit protected by an ELCB.
Do not apply power to the spa unless it is filled with water to the normal water level, which is to the water level indicator mark on the skimmer frame. Activating the spa when there is an insufficient amount of water can damage the circulation pump and may cause a fire.
Read manufacturer’s safety information provided with all optional equipment.
Purchased From
Installed By
Spa Serial Number Model #7700000
(See page 2 for location of serial number.)
www.clearcreekspas.com
www.clearcreekspas.com
TM
The Quantum Plus Portable Whirlpool Spa
Owner's Manual
Model 770000
Contents
Installation Instructions __________________________________ 3-6
Inspection and Shipping Claim ______________________________ 3 Unpacking ______________________________________________ 3 Positioning Your Spa ______________________________________ 4 Electrical Requirements ___________________________________ 4 Electrical Precautions _____________________________________ 4 Outdoor Installation _______________________________________ 5 Drainage _______________________________________________ 5 Indoor Installations _______________________________________ 5 Equipment Set-Up ________________________________________ 6
Operating Instructions ___________________________________ 7-11 Basic Control Set-Up ______________________________________ 7 Setting the Time _________________________________________ 8 Controls ________________________________________________ 9 Temperature Control ______________________________________ 10 Setting the Thermostat ____________________________________ 10 Note on Determining Water Temperature ______________________ 10 Normal Operation ________________________________________ 11 Whirlpool System ________________________________________ 11 Water Rainbow __________________________________________ 11 Air Blower ______________________________________________ 11 Silent Air Induction _______________________________________ 11 Filtration _______________________________________________ 11
Maintenance ___________________________________________ 12-16 Water Quality and Water Chemistry __________________________ 12 Filtration _______________________________________________ 12 Water Chemistry _________________________________________ 12 Disinfecting _____________________________________________ 12 Balancing pH ____________________________________________ 13 Balancing Total Alkalinity __________________________________ 13 Water Quality Definitions ___________________________________ 13 Water Level/Drain ________________________________________ 14 Skimmer Basket Maintenance ______________________________ 14 Filter Maintenance ________________________________________ 14 Automatic Filtration/Maintenance ____________________________ 15 Winterizing _____________________________________________ 15 Factory Installed Redwood Skirt _____________________________ 15 Spa Light _______________________________________________ 16 Cleaning Your Spa _______________________________________ 16 Covering Your Spa _______________________________________ 16 Repairs to the Acrylic _____________________________________ 16
Troubleshooting Guide ___________________________________ 17-19 Alternate Use of Water Rainbow _____________________________ 20
www.clearcreekspas.com
www.clearcreekspas.com
1
www.clearcreekspas.com
www.clearcreekspas.com
The Quantum Plus Portable Whirlpool Spa
Installation Instructions
The Quantum Plus is a sumptuous, rectangular whirlpool spa by Jacuzzi Whirlpool Bath designed with full-featured elegance to provide the comfort and luxurious spa experi­ence you expect from a Jacuzzi whirlpool spa. Multi-level contours allow for seating and lounging for 7 people. A built-in step and handrail allow safe entrance and exit from the spa. And for a revitalizing hydromassage, six fully adjustable color coordinated whirlpool jets and one directionally adjustable jet are located strategically to massage lumbar and upper back regions, depending on where you are seated.
For the ultimate in convenience, the Quantum Plus fea­tures two clearly labeled control panels, one located on either side of the spa and concealed by a streamlined tinted acrylic cover. One panel allows push button control of the heater, filter, whirlpool, lights and air blower functions and adjustment of silent air induction. The other control panel offers additional air induction adjustment. A 7-day timer (located on the System Control Module) can be set for automatic control of temperature and filtration. The Quantum Plus also features two low voltage lights and interchangeable colored lenses, adding even more luxury and excitement to your spa experi­ence.
The Quantum Plus offers the convenience of two patented front-load skimmer/filters for maximum efficiency. The unique
4.65m2 (50 sq feet) filtration system, designed by Jacuzzi Whirlpool Bath, allows easy access from inside the spa to both filter cartridges without having to drain the spa or open the skirt door.
A standard feature of the Quantum Plus is its two Water Rainbow spouts with flow control, which will create a daz­zling, shimmering waterfall effect while recirculating the water.
The spa shell is foam insulated to save energy costs, and the spa is tastefully surrounded by a factory installed redwood skirt.
The complete equipment pack of the Quantum Plus is mounted within the perimeter of the spa, so the spa is easy to install. The spa requires a 230 VAC 50 AMP, grounded separate circuit and is equipped with an ground fault circuit interruter (GFCI). An optional gas heateris available as an
SPECIFICATIONS
MODEL Qauntum
Plus
DIMENSIONS
94" (2388 mm) L.
WHIRLPOOL MOTOR/ PUMP
2.0 h.p.(1.5 kW)
FILTER MOTOR/ PUMP
.75 h.p.(.6 kW)
www.clearcreekspas.com
TOP VIEW
SIDE VIEW
alternate heating source and can be used remotely. The Quantum Plus is available in several lustrous colors. (See the Jacuzzi Whirlpool Bath color guide.)
OPTIONS
Gas Heater Rigid Insulating Cover
Pillows
OPERATING GALLONAGE
400 U.S. Gal. 87" (2210 mm) W.
ELECTRIC HEATER
6KW 230 VAC 361/2" (927
94"
SERIAL NUMBER LOCATION
PRODUCT WEIGHT
740 lbs. mm) H. 10 AMP
SHIPPING WEIGHT
975 lbs.
ELECTRICAL REQUIREMENTS
230 VAC
3 4
87"
36 1/2"
5 0
230 VAC
R
4.9 AMP
P
3450 RPM Single Phase
M
60 Hz.
S i n g l e
P h a s e 6 0
H z .
2
www.clearcreekspas.com
(1514 ltrs.)
26 AMPS
(340 kg.)
(443 kg.)
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
5 0
A M P
S e p e r a t e
C i r c u i t (See page 4)
www.clearcreekspas.com
www.clearcreekspas.com
INSTALLATION
Installation Instructions
Inspection and Shipping Claim
Check for shipping damage upon receipt of the spa. Jacuzzi Whirlpool Bath is not responsible for damage to the spa sustained during shipping. If damage is evident before unpacking, see instructions regarding shipping claims on the outside of the carton and immediately file a claim with the carrier.
Once the spa has been removed from the carton and before it is permanently installed (see below on this page for unpacking instructions), check the spa completely for damage. Fill the shell with water and operate the system (see Operating Instructions) to check for leaks which may have resulted from shipping or handling. All Jacuzzi Whirlpool Bath spas are factory tested for proper operation and watertight connections prior to shipping. If leaks or other problems are detected, immediately notify your Jacuzzi Whirlpool Bath dealer or Authorized Service Agent, or call Jacuzzi Whirlpool Bath, (510) 938­7411, for Warranty Service, (510-938-7411).
Npte: Damage or defects which could have been discovered anr repairedprior to installation and which are claimed after final installation of the spa, are excluded from our warrenty.
Unpacking
1. Remove the outer carton by disassembling bracing and plastic bags. Leave the inner bag and corrugated wrapping in place on the skirt to protect the product until equipment set-up.
2. Remove the box containing skirt panels and the acces­sory package which contains the Owner’s Manual, filter, cartridges, and extra lenses and bulbs. Set aside skirt panels until equipment set-up. Set aside the filter cartridges in a dry place until it is time to set up the spa equipment. Store the extra lenses and bulb for later use.
3. The spa should be moved on a dolly in its upright position while still attached to its shipping pallet. If the pallet must be detached before the spa is moved (for example, to allow it to pass through a door), detach it from the pallet as instructed below, then carefully place it vertically on a dolly which is wide enough to support the entire width of the spa. The skirt is cosmetic (not structural) and is not designed to support the spa.
4. When the spa has been moved to its final location, place a wooden block approximately 100mm x 100mm x 2m (4" x 4" x 72") beside the pan side of the spa so it is parallel with the pallet. (See illustration B.)
5. Tip the spa over onto its bottom with the block support­ing the spa.
6. Remove the brackets attaching the spa to the pallet. (See detail B.)
7. Remove the bolts securing the pallet to the upper part of the spa shell.
8. Remove the 100mm x 100mm (4" x 4") block and pallet and carefully lower the spa to a horizontal position.
9. Attach two loose skirt panels included in skirt box.
10. Record the spa serial number on the inside front cover of this manual. (See illustration on page 2 for the serial number location.)
Important! Read all the instructions contained in the Owner’s Manual before beginning installation.
SKIRT
DETAIL
BOLT
PAN
PALLET
www.clearcreekspas.com
www.clearcreekspas.com
PALLET
4" X 4" X 72"
BLOCK
3
www.clearcreekspas.com
www.clearcreekspas.com
INSTALLATION
Important: Read complete instructions before beginning installation.
Positioning Your Spa
Because your Quantum Plus spa is a portable, you can locate it just about anywhere you wish—on a deck, patio, or even indoors. Just be sure to position it above ground in an area with good drainage and on a level, continuous surface which can support the weight of the spa when filled with water and people; this weight is approximately 5252 lbs. (92 lbs. per sq ft). You must also provide access to the spa’s equipment for service and general maintenance.
Electrical Requirements
Your Quantum Plus, as it comes from the factory, requires a 230 VAC 50 AMP 4-wire grounded type electri­cal service and must be in a separate circuit having no other appliance connected in that circuit. If you do not have this kind of circuit, a qualified electrician should be called in to install the necessary wiring. Inadequately sized wiring or locating the spa too far from the main service panel may cause a voltage drop which might cause the unit to
SERVICE ACCESS
18"
50"
malfunction and bring about permanent damage to the spa’s electrical system. The circuit must also have a ground wire in order to take advantage of the designed-in safety features of the spa. Bond according to procedure described on the next page. Caution: Without proper grounding and bonding, a system malfunction may cause fatal shock.
www.clearcreekspas.com
www.clearcreekspas.com
4
www.clearcreekspas.com
www.clearcreekspas.com
INSTALLATION
Electrical Precautions
CAUTION
Do not apply electrical power to the spa unless it is filled with water to the normal water level, which is approximately 7" below the spa rim. (See location of water level indicator on face of skimmer on page 6.) If the spa’s motor/pumps are actuated when there is not sufficient water in the unit, the circulation pumps could be irreparably damaged. In addition to damaging the unit, operating the unit with insufficient water could cause a fire.
Do not locate lighting fixtures directly above the spa; lighting and electrical receptacles must be located at least 5 ft (1.5m) from the spa. Lighting located between and 5 ft (1.5m) and 10 ft (3m) from the spa must be on a circuit protected by a ELCB. (See National Electrical Code 680-
6).
Outdoor Installation
If you install the spa outdoors, we recommend that you provide a concrete pad for it to rest on. To do this, construct forms for a 8' x 8' x 4" thick level pad.
Install a #10 gauge wire mesh approximately 6" x 6" steel reinforced grid. Attach a #8 solid copper wire to the grid with a ground clamp. This wire should be long enough to reach the bond bar on the spa System Control Module (min 36"), but should not be located under the base of the spa. Then pour the concrete pad.
Drainage
Whether you install your spa indoors or outdoors, you can drain it completely by attaching a garden hose to the drain valve located on the suction tee of the spa. Simply run the hose to the house sewer line or drain field and open the drain valve.
Make sure the area surrounding the spa has good drainage to keep water from collecting at the base of the
SUPPORT AND DRAINAGE
#8 BOND WIRE (TO HOUSE ELECTRICAL PANEL OR LOCAL BOND)
TO BOND BAR
www.clearcreekspas.com
Do not use electrically connected devices, such as television, radio, telephones, stereo speakers, lights or cooking devices within 5 ft (3m) of the spa when the spa is being used.
All fixed metal objects located within 5 ft (1.5m) of the spa, such as fence posts, railings, door frames, green­house structures, gutters, etc., must be attached to the bonding bar on the outside of the spa System Control Module using #8 solid copper wire. With #8 solid copper wire, bond the spa to the house electrical panel or approved local earth electrode.
An approved earth electrode may be an 8 ft. long earth rod, a plate electrode, or a buried metal water pipe with at least 10 ft. of buried pipe. Check your local building code for requirements. Bonding lugs are avail­able at your local electrical supply store. (Bond bar location is shown on page 5.)
spa—especially near the equipment area. If drainage is poor, install a drain line and/or gravel drain field (see illustration below).
Indoor Installations
Water which splashes on the floor during use of the spa may cause a walking hazard and/or structural dam­age unless good drainage is provided and proper water­proof building materials are used in the area surrounding and beneath the spa. Take into consideration, also, the high room humidity which will exist due to high spa water temperatures. Providing natural or forced ventilation of the room will help maintain comfort and minimize mois­ture damage to the building. Jacuzzi Whirlpool Bath is not responsible for damages resulting from excess mois­ture or water spillage. Consult an architect or engineer for aid in designing your indoor installation.
WIRE MES H GRID
8' x 8' x 4" THICK CONCRETE PAD
www.clearcreekspas.com
BOND BAR
5
GRAVEL DRAIN FIELD
www.clearcreekspas.com
www.clearcreekspas.com
Equipment Set-Up
1. Remove the plastic sheet covering the spa. Use care; stepping into the spa with shoes will scratch the acrylic surface.
2. Remove any packing materials from the spa.
3. Remove each filter cartridge from its plastic bag.
4. Pull open each skimmer/filter door by the handle lo­cated in the middle of the door and remove the skimmer basket. Then insert the filter cartridge into the filter housing and re-insert the basket so that it fits in place over the filter cartridge and close the skimmer/filter door.
5. Clean the interior of the spa of any remaining construc­tion debris. Remove stubborn stains, paint, or tar with turpentine, isopropyl alcohol or paint thinner. A mild liquid dishwashing detergent on a damp cloth is fine for cleaning off other dirt. Plaster can be removed by scraping with a wooden edge; do not use a metal scraper, wire brush, or other metal tools, as they will damage the spa’s surface.
6. Install the skirt panels which were not installed on the spa at the factory. To do this, secure with the screws provided in your spa accessory package and follow instructions provided with panels.
7. On initial start-up, it is necessary to purge and sanitize the system. Carefully follow the procedure described here to purge and sanitize your spa.
• Remove the spa cover completely.
• Close the drain valve located on the suction tee.
• Fill the spa with water to its normal operating level,
which is to the water level indicator mark on the skimmer/filter frame.
• Turn on circuit breakers at the main electrical panel.
INSTALLATION
• Select JETS on the SYSTEM switch.
• Add 60cc sodium dichlor (a fast dissolving granulartype of chlorine) to the water and let the whirlpool run for 15-20 minutes only.
• Turn off JETS.
• Turn off circuit breakers.
• Immediately open the drain valve and drain the spa completely.
CAUTION: Leave the rigid cover off the spa during this procedure. Do not use the spa during this procedure. Drain the spa immediately afterward.
8. Close the drain valve and fill the spa with water to approximately 180mm (7") below the spa rim, or to water line indicator mark on the skimmer frame. (See illustration on this page.)
9. Turn on circuit breakers at the main service panel.
10. Set the heater thermostat for the maximum tem­perature.
11. Test the spa for proper operation. (Refer to Operating Instructions.)
12. Refer to Water Quality section of the Operating Instructions. Test for water quality; then add treatment chemicals to ensure proper levels.
All Jacuzzi Whirlpool Bath spas are factory tested for proper operation and watertight connections prior to shipping. If leaks or other problems are detected, immediately notify your Jacuzzi Whirlpool Bath dealer or Authorized Service Agent, or call Jacuzzi Whirlpool Bath, (510) 938-7411 (510-938-7070 in California), for Warranty Service.
www.clearcreekspas.com
Loading...