REFRIGERATION PRODUCTS KITCHEN PRODUCTSLAUNDRY PRODUCTS
COMMERCIAL LAUNDRY
THIS SERVICE POINTER APPLIES TO THE FOLLOWING BRANDS:
MAYTAG PRODUCT UPDATE
Product Update Information
MODEL NUMBERS: MFI226AE*
On/Off
R8178695
September 2007
Humidity
Control
Power off
cooling system
press 3 sec
A new 22 cubic ft French Door refrigerator with ice and water (Iceland) is being introduced Fall 2007. The user interface
incorporates two new customer options; Power off and Humidity Control. The function and programming of these options are
explained for the consumer in the Use and Care Manual. It is important that the consumer understands the function of these
options to prevent unnecessary service calls.
The built in service diagnostics and troubleshooting codes remain the same as previous Iceland units. Refer to the Technical
Data Sheet shipped with the unit for information specic to the model you are servicing.
.
NEW USER INTERFACE DISPLAY 22 CUBIC FT. ICELAND
page 1 of 3
ALL SERVICE POINTERS ONLINE: http://www.servicematters.com/tech_ref/tech_ref_main.htm, SERVICE POINTERS
COMMERCIAL LAUNDRY ONLY: www.whirlpoolcorp.com/cltpsc, TECHNICAL INFORMATION, SERVICE POINTERS
To receive pointers by email or FAX, or to edit or delete a current email or Fax from our distribution, see
http://www.whirlpoolcorp.com/cltpsc/feedback/feedbacksubscribe_all.html, or FAX changes to 269-923-5805.
(continued on next page)
On/Off
Power off
cooling system
press 3 sec
.
Power Off Pad
“Power Off Cooling System” describes the loads which will be turn off by that switch. “Press for 3 seconds” indicates to the
customer that the button must be pressed for a minimum of 3 seconds before feature activates.
• The Power Off key will turn the Cooling System OFF/ON as described below. When turning the Cooling System OFF,
all keypad LED’s will turn off, the 7 segment LED display will turn off, and a double beep will sound upon implementation. The
red LED associated with the Cooling On/Off switch will turn on. Any key press, not including the Cooling On/Off key, will be
ignored and an error beep given. The Cooling On/Off LED will also ash in such instances.
• In the OFF state all cooling functions (compressor, fans, and damper) operation, as well as defrost operations will
be turned off. (This will include any periodic damper cycling functions.) Water dispense operations will NOT be permitted
according to the general specications. Entry into the Service Mode and Personality Programming Mode will be permitted.
Access to Forced Defrost and the User Preference Menu will be denied.
• To turn the Cooling System back ON, press the Cooling On/Off key (no press and hold is required to turn the system
back on). No sound is generated for this event and the associated LED will turn off. The unit will turn ON and return to the
last saved set points. Any features that were previously enabled will become active, except for the Max Cool and Sabbath
functions. The Sabbath and Max Cool functions will be cancelled upon entering the Cooling On/Off mode.
• Prior to turning off the UI, the current user settings will be stored in EEPROM to be able to recover the customer
settings in case of an electrical reset.
page 2 of 3
(continued on next page)