GB EXTRACTOR OR FILTERING HOOD INSTALLATION

The minimum distance between the cooker support surface and the lowest part of the hood must not be less than 45 cm, for gas and 30 cm for electric cookers (70 cm from controls as per enclosed drawing) If the installation instructions for the gas cooker specify a greater distance, this must be taken into account. The fume hose and hose clamps are not supplied. We recommend that you contact a qualified engineer to have the hood installed.

Gas cooker

Electric cooker

Also consult the drawings on the first pages of this booklet, with alphabetical references in the description.

Always comply with the instructions and recommendations given in this manual. The Manufacturer declines all liability for any faults, damage or fires caused by the appliance as a result of failure to observe the instructions and recommendations given in this manual.

If the hood is used in FILTER version it is used without an exhaust fume discharge pipe. Fumes and vapour are recycled through the deflector F (11F).

If the product is to be used in EXTRACTOR version, it is necessary to provide an exhaust pipe from the top outlet B to the external outlet vent.

In this case a collar (11A) must be fitted on the exhaust outlet B and the carbon filter must be removed. A telescopic flue is also available (as an accessory).

Preliminary information for installing the hood:

Expansion plugs are provided to secure the hood to most types of ceilings. However, a qualified technician is needed to make sure that the plugs are suitable for your ceiling. The ceiling must be strong enough to take the weight of the hood.

Only for some models

An aesthetic flue can be purchased as an optional accessory. Please check with your After-sales Service to find out whether or not your model. has this option.

In order to ensure that it is installed in the most suitable way, it is recommended that you only fit the hood after purchasing the flue.

Disconnect the power supply at the domestic main switch before carrying out electrical connections.

Apply the (adhesive) rubber strips C to the back of the hood.

If necessary (if the wall is not perfectly vertical or if it is partially tiled) fit two spacers D in correspondance with the final fixing holes (snap-fitting).

Trace a centre line on the wall to facilitate installation (1), position the drilling template on it so that the central line printed on the template matches the central line marked on the wall and the bottom part of the template is aligned with the bottom of the hood when mounted (2).

Drill two holes (Ø 8 mm) and fix the support bracket to the wall using two wall plugs and screws (3).

Remove the steam deflector and take out the grease filter (see relevant paragraph).

Hang the hood (4), adjust its position (5 - 6) and from the inside of the hood mark two points for final fastening (7), remove the hood and drill two holes (Ø 8 mm) (8), insert two wall plugs, hang the hood again and fasten it to the wall with two screws (9).

Carry out the electrical connection (10), but leave the hood disconnected from the main power supply.

If the hood is to be used in the extractor version, fit the collar supplied on the hood outlet (11A - extractor version - also install an exhaust pipe of suitable diameter) in place of the deflector (11F - filter version).

Fit the grease filter, fit and close the steam deflector.

Warning! If the hood is to be used in the extractor version, remove the carbon filter if there is one, along with the fixing elements (behind the grease filter - see relevant paragraph).

If the hood is to be used in filter version, check that the carbon filter has already been fitted at the back of the grease filter, and if this is not the case, purchase a carbon filter and fit it.

Connect the hood to the main power supply.