IMPORTANT:
Gas Large Capacity ThinTwin
Washer °Dryer - 120 Volt
Installation Instructions
Read and save
these instructions.
IMPORTANT: Installer: Leave Installation Instructions
Homeowner: Keep Installation Instructions
for future reference.
Save Installation Instructions for local
electrical inspector's use.
pool.tom
Part No, 3395326 Rev. F
Before you start..•
Your safety and the safety of others are
very important.
We haveprovidedmany important safetymessages in this manualandon your appliance.Arwaysread and obey all safety messages.
[pl_ This is the safetyalert symbol.
This symbol alerts youto potential
hazardsthat can kill or hurt you and others
All safety messageswill fellow the safety alert symbol and either the word "DANGER"or
"WARNING".Thesewords mean:
Check location where washer/dryer will be installed Proper installation isyour responsibility. The washer/dryer must not
be installed or stored in an area where it will be exposed to water and/or
weather Make sure you have rigid everything necessary for correct _p_y installation
Grounded electrical _oupling
ouhet is required. See 38" win to 41"
"Electrical from floor i
requirements." i
1/8-inch NPTplugged i
tapping is required.
(See Panel B,Step L)
Thisa c wall, The cable bracket must be
secured to a wal! stud within a 27 inch-wide area that is28 inches
minimum to 41 inches maximum
from floor. (See Panel F.) Standpipe drain system:Needs
a two-inch diameter standpipe with minimum carry-away
capacity of 17 gallons per minute Top of standpipe must
be at least 34 inches high and no higher than
72 inches from floor Floor drain system requires a
siphon break, Part NO. 285320, available from a WhirlpooP
authorized parts distributor,
g_s supply line
rnQx.
Youcan be killed orseriouslyinjured if you don't imm_ follow instructions.
Youcan bekilled orseriously injuredifyoudon't follow instructions.
All safety messageswill tell youwhat the potential
hazardis, tell you how to reducethe chanceof injury, andtell you what can happeeif the
instructions are not followed.
Hot and cold
gasshulOe
valve
Support: Floor must be sturdy enough
- to support washer/dryer weight, with water and clothes, of 500 pounds
water faucets:
Must be within 4 feetof the back ofthe
washer/dryer
and provide water pressure
of 5 -100 PSI
WARNING: For your safety the
information in this manual J
Do Not store or operate washer/dryer below 32_F(some water may remain in washer).
Proper operation of dryer cycles requires temperatures above 45°F. See Use & Care Guide for "Winterizing" information.
Check code requirements:Some codes limit or do not permit installation of clothes
dryers in garages, closets, mobile homes and sleeping quarters. (Contact your local building inspector)
Check utilities:Proper gas, water and electric supply connections must be
available.
Water heater:Settodeliver140°Fwatertothe
washer
Laundrytub drain system: Needs a 20 gallon laundry tub Top of tub must be at least
34 inches high and no higher than 72 inches from floor.
If a longer drain hose isneeded, drain hose (Part No, 388423) and hose extension kit (Part No 285442) are available from Whirlpool- authorized parts distributors.
Dryer may be exhausted from the rear or left or right side. Exhausting through the
side requires Part No. 3391335 (See
"Exhaust requirements," Panels B
and C)
Four-inch metal exhaust
vent isrequired.
SEERECESSEDAREA
INSTRUCTIONS ON PANELG.
Important: Observe all governing codes and ordlnonces.
Levelfloor:
1-inch maximum slope
under entire washer/dryer.
Tools and materials needed for installation:
must be followed to minimize I the risk of fire or explosion or I to prevent property damage,
persona njury or death.
eat-blade used, it should be 1/2-inch IPS Pipe-joint
Phillips screwdriver
screwdriver compounds resistant to the action of
adiustable shutoffvalve
may be
_ to "open" posJSon_,
wrench(two
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Failure to do so can result in death, explosion, or fire.
Location: Should be large enough to fully
open dryer door to 90°. (See Panel G for "Recessed and closet installation
instructions" and "Product dimensions ")
-- Do not store or use gasoline
or other flammable vapors and liquids in the vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL
GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or
level requir dryer _
A 1" x 4" x 24" board and fasteners ale also FI The supply line shall be equipped required (but are not included with this produCt), wJflh a shutoft valve. This valve $h ouJd be
Gas supply-- washer/dryer and should be in
area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
re-uSremen's,.xs location that allows ease of opening
OBSERVE ALL GOVERNING CODES shutoff valve. AND ORDINANCES
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
-- installation and service must be performed by a qualified
installer, service agency or
the gas supplier.
Use a new AGA or CSA approved gas
supply line. H
Install a shut-off valve. This washer/dryer is equipped Securely tighten all gas connections, with its own permanent, flexible gas
If connected to LP, have a qualified International, for connecting the
_erson make sure gas pressure does appliance to the gas supply line.
not exceed 13" water column. Examples of a qualified person include Copies of the standards listedmay be obtained from:
licensed heating personnel, authorized "CSAIntemaSonal gas company personnel, and 8501EastPleasantValle Road
authorized service personnel. *'National FireProtectionASSOciation
Failure to do so can result in death, BoffemmarchPark
explosion, or fire. Quincy, Massachusetts02269
Explosion Hazard Recessed and cksset installations)
Panel A Panel B
AnThis installation must conform with
American National Standard, National
Fuel Gas Code ANSI Z223 1 -- latest edition,* and all local codes and
ordinances.
B nThe design of this dryer has been
certified by CSA International for use at altitudes up to 10,000 feet above sea level at the D.T,U.rating indicated on the model/serial plate. Burner input adjustments are not required when the dryer isoperated up to this elevation.
When installed above 10,000 feet, a four percent (4%) reduction of the burner
B.T.U. rating shown on the model/serial plate isrequired for each 1,000 foot
increase in elevation For assistance when converting to other gas types
and/or installing above 10,000 feet elevation, contact your local service
company.
C L
Check that this _=
dryer isequipped with the correct burner for
the particular type of gas in the home.
Burner information will be found on the rating plate in the door
well of the appliance If this information does not agree with the type of gas
available, see your dealer.
D •This dryer is equipped for use with
NATURAL GAS It is certified by CSA International for manufactured, mixed
and LP. (propane or butane) gases with appropriate conversion No altempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the service gas supplier or a Whirlpool designated service company.
Conversion must be done by a qualified service technician. Gas conversion kit
pad numbers are listed on the burner bracket behind the access panel. (See Panel E.)
E Provide o rigid gas supply line to
the dryer location When rigid pipe is
LP. gas must be used.
located in the same room as the
and closing, Do Not block access to the
G i If the washer/dryer is Installed in a
confined area such as a bedroom, bathroom or closet, it must be exhausted to the outside and provision
made for enough combustion air and ventilation air. (Check governing codes
and ordinances. Also refer to the section in this instruction covering
connector, design certified by CSA
Cleveland,Ohio44131-_575
gas
supply
a
I.]f rigid pipe is _o_m_:_uen.°'l_
used as a gas
supply line, a pipe fiiffings must
be used to Do
obtain an in line pipe_jolnt connection to compound.
the washer/dryer, flexible as i_
J• Make sure the back and sides of
the cabinet are free of obstructions to
permit adequate clearance of air
openings for combustion air (See
"Recessed and closet installation instructions" for minimum spacing
requirements, Panel G)
K• For ease of installation, operating
and servicing (if ever needed), adequate space should be provided
around the washer/dryer.
L= An 1/8-inch NPT plugged tapping,
accessible for test gauge connection,
must be installed immediately upstream of the gas supply connector to the
dryer. The dryer and its individual shutoff valve
must be disconnected from the gas
supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa)
The dryer must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.45 kPa).
connec_(_r
Electrical requirements
Electrical Shock Hazard
Plug into a grounded 3-prong outlet. Do not remove ground prong.
Do not use an adapter. Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Impodant: Observe all governing codes
and ordinances.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the ground path isadequate.
A three wire, single phase, 120 volt,
60 Hz, AC-only, 15- or 20-ampere, fused,
electrksal supply is required. A time- delay fuse or circuit breaker is recommended. If your home has a circuit wired and fused for 20 amperes,
this is preferred. If you are installing a
new circuit, one wired and fused for 20 amperes is recommended It is also recommended that a separate circuit
serving only this appliance be provided.
Recommended ground method
For your personal safety, this appliance must be grounded This washer/dryer is
equipped with a power supply cord having a 3 prong ground plug. To minimize possible shock hazard, the
cord must be plugged into a mating, 3-prong, ground-type outlet, grounded
in accordance with the National Electrical Code, ANSI/NFPA 70 latest edition,** and all local codes
and ordinances. (See Figure 1) If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3 prong outlet installed by a qualified electrician.
- greu.2-
.1 pro•
greun2 outlet IIF -,ll
power
cord ground
supply p_U_d
S-pro•
Replace any pk:_c or metal foil vent with rigid
metal or flexible metal vent.
Useclamps te seal all
joints DO not use duct
tape, Screws or other fastening devices that extend into the interior
of the vent to secure vent. Se_,ice check: Back pressure in any exhaust
system used must not exceed 0.6 Inches in water column mecs,Jred wtn an incline
manometer at fine point hat exhaust vent connects to dryer,
exhaust air flow
Mobile home installation
This appliance issuitable for mobile
home installatlons. The installatlon of the
washer/dryer must conform to the
Manufactured Home Construction and
Safety, Title 24 CFR, Part 3280 (forrnedy the Federal Standard for Mobile Homes
Construction and Safety, Title 24, HUD
Part 280, latest edition).
For all installations, this I2_ 1
appliance MUSTbe fastened to the wan with
cable bracket and MUST _1:_
be exhausted to the _]
outside. Exhaust system
hardware isavailable
through your Whirlpool dealer.
Mobile home exhaust requirements: The
washer/dryer must have an outside exhaust.Ifthe dryerisexhausted through the floorand the area under the mobile home isenclosed,the
exhaust system must terminateoutside the enclosed area. Extensionbeyond the enclosure willprevent lintand
moisture buildup under the mobile home,
Figure 1
Exhaust requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent. Do not use a metal foil vent.
Failure to follow these instructions
can result in death or fire.
Impodant: Observe all governing codes and ordinances.
Exhaust your dryer to the outside.
Moisture and lint indoors may cause:
Lint to gather around the dryer where it can be fuel for a fire.
Moisture damage to woodwork,
furniture, paint, wallpaper, carpet, etc.
Housecleaning problems and hea)th problems,
If the washer/dryer isinstalled in a confined area such as a bedroom,
bathroom or closet, it must be The exhaust vent can b( I_
exhausted tothe outsideand provision routed up, down, left,
must be made for enough air for right or straight out the ventilation. Check governing codes and back of the ordinances. Also refer to the "Recessed washer/dryer Space and closet installation instructions" on requirements are Panel G. provided on Panel G of Dura Safe TM vent products are the Installation I0, recommended and ore availablefrom Instructions and on the 19.
your dealer. See Panel G. rear panel of the Four-inchdiameter _ isrequired.
Useo heavy melol vent. Do nat use plasfle or metal foil vent,
Do Not use r_n_netal flexible vent, or exhaust hoods with magnefle latches
Do Not exhaust dryer into a chimney, furnace, cold air vent, attic or crawl space, or any other vent used for venfleg
Do Not installflexible vent inenclosed walls, ceilings or floors.
Rigidmetal vent is recomrnended to prevent crushing and kinking.
Flexiblemetal vent must be fully extended and supported when 1he dryer isin itsfinal
positon Remove excess flexible vent to avoid sagging and kinking that may result in
reduced air flow An exhaust hood _hould cap tne exhaust
vent to prevent rodents and insects from entering the home. Exhaustoultel hood must be at least 12
inches from the ground or any object that maybe inthe path of the exhaust (such as
flowers, rocks or bushes, etc.). tl udng an e_dstingexhaust system,clean lint
Plan installation to use the fewest number of elbows and turns,
Maximum length of the exhaust system
depends upon the type of vent used, number of elbows and the type of exhaust hood. The maximum length for both rigid and flexible vent isshown in
the chaff.
2.1/2 _'
Rear, Side or Bottom Exhaust
Number
of 90° Tums
O 42 FT. MAXIMUM
1 34 FT, LENGTH OF
2 26 FT. 4" DIA, RIGID
METAL VENT
0 26 FT MAXIMUM
1 21 FT LENGTH OF
2 16 FT 4" DIA FLEXIBLE
METAL VENT
washer!dryer
Four-inch outlet hood is preferred.
However, a 2-1/2-inch outlet exhaust hood may be used A 2-1/2-inch outlet
creates greater back pressure than Numbers other hood types
Exhausting the dryer through the side of the
washer!dryer requires the use of Side Exhaust
Kit, Part No. 339133B Follow kit installation
instructions for proper exhaust installation.
For exhaust systems
not covered by the exhaust length chart, see Whirlpool Service Manual, Exhaustina Whirlpool
Part No. 603197, available from
your Whirlpool parts distributor
A closet installation must be exhausted oulside. See "Recessed and closet
installation instructions" on Panel G for adequate unobstructed air opening
requirements.
Now start...
With washer/dryer in laundry area.
Use two or more people to move and install washer/dryer.
Failure to do so can result in back or
other Injury.
Truck only from rear to prevent product damage.
•Open washer lid. Take hoses and
parts packages out of basket. Close lid.
correspond
to steps.
Excessive Weight Hazard
30.
fromeaErele_31hofsystemand make sure
e_'_st hood isnot plugged wilh lint.
Panel C
U/
HL
connector must be connected In a Flexible ga_
slngle, nalural loop.
I hose clamp
4 flat, water-hose washers
4 cable-bracket screws
1 small clamp
Remove parts from package
Check that all parts were included
Pullthe
shipping
strap
com.pletely
out of the
washer.
Pull to completely remove the
shipping strap with 2 cotterpins from the inside of the washer/dryer.
Save the shipping strap for use in Step 18.
mTilt washer/dryer forward. Check
that rear leveling legs move up and
down freely so that washer/dryer can be properly leveled in Step 15.
Usenew hoseand washersthat came with yourwasher/dryer.
Replace inlet hoses after 5 years of use
to reduce the risk of hose failure Inspect
and replace inlet hoses if bulges, kinks, cuts, wear, or leaks are found When
replacing your inlet hoses, mark the date of replacement on the label with a permanenl marker.
mouated 1o a I" x 4"
board, 24" long, that Js
Caple bracket must be I J
securely mounted (}cross twO wall studs or
on a concrete wall, (See Panels D and F.)
23. 24.
=
11.
18.
Pull shipping strap with 2 coflerpins
completely out of
washer,