Whirlpool LTG6234D User Manual

®
Gas Washer/Dryer
PRODUCT MODEL NUMBER OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
DRAIN SYSTEM
EXHAUST VENTING
LTG6234D
Gas supply: Dryer is equipped for use with
Electrical: A 120-volt, 60-Hz., AC-only, 15- or
20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this appliance be provided. Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust. The dryer can be converted to exhaust out right or left side.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8572777 Rev. A
12-12-05
Additional clearances might be required for wall, door and floor moldings. Rear clearance may be 0" when house exhaust system is lined up directly with dryer exhaust.
Standpipe drain system - wall or floor
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter standpipe adapter kit is available.
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the bottom of the washer.
Laundry tub drain system
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system
The floor drain system requires a siphon break that may be purchased separately. The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses
might be needed.
71 ⁵⁄₈ "
(181.9 cm)
*32"
(81.3 cm)
23 ³⁄₄ "
(60.3 cm)
32 ¹⁄₄ "
(81.9 cm)
27"
(68.6 cm)
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
1"
(2.5 cm)
1"
(2.5cm)
27"
(68.6cm)
1"
(2.5 cm)
32"
(81.3 cm)
5
¹⁄₂ "
(14 cm)
48 in.
2
(310 cm 2 )
24 in.
2
(155 cm 2 )
6" (15.2 cm)
3" (7.6 cm)
3" (7.6 cm)
AB
C
Vent Length Chart
°
°
xi
No. of 90° turns or elbows
Type of Vent Box or
Louvered hoods
Angled hoods
0 Rigid metal
Flexible metal
37 ft (11.3 m) 25 ft (7.6 m)
35 ft (10.7 m) 20 ft (6.1 m)
1 Rigid metal
Flexible metal
32 ft (9.7 m) 21 ft (6.4 m)
27 ft (8.2 m) 16 ft (4.9 m)
2 Rigid metal
Flexible metal
24 ft (7.3 m) 15 ft (4.6 m)
19 ft (5.8 m) 10 ft (3.0 m)
NOTE: Side and bottom exhaust adds a 90 turn inside the washer/dryer. To determine maximum exhaust length, add one 90 turn to the chart.
Angled hood style
* Most installations require a
minimum 5¹⁄₂" (14 cm) clearance behind the dryer for the exhaust vent with elbow.
A. Louvered hood style B. Box hood style
A
B
Plan installation to use the fewest number of elbows and turns. Maximum length of the exhaust system depends upon the type of vent used, number of elbows and the type of exhaust hood. The maximum length for both rigid and flexible vent is shown in the chart.
2
4"
(10.2 cm)
(6.4 cm)
1
4" (10.2 cm)
4" (10.2 cm)
1. Louvered hood style
2. Box hood style