Whirlpool LTE5243DQA, LTE5243DQ9, LTE5243DQ8 Dimension Guide

®
24" (61 cm) Electric Washer/Dryer
PRODUCT MODEL NUMBER PRODUCT DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
DRAIN SYSTEM
EXHAUST VENTING
LTE5243D
Electrical: A three- or four-wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or three- or four-wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line must be provided. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Do not use an extension cord.
Exhaust venting: Exhaust your dryer to the outside. Use a heavy metal vent. Do not use plastic or metal foil vent. 4" (102 mm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. Exhaust outlet hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust. The dryer can be converted to exhaust out right or left side.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10222387
10-31-08
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Standpipe drain system - wall or floor
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter standpipe adapter kit is available.
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the bottom of the washer.
Laundry tub drain system
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system
The floor drain system requires a siphon break that may be purchased separately. The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses
might be needed.
15 "
(39.1 cm)
71 ¾"
(182.2 cm)
*27 ¼"
(69.2 cm)
23 "
(60.6 cm)
32 "
(81.6 cm)
3
8
1
8
7
8
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
1
"
(2.5 cm)
1"
(2.5 cm)
AB C
3" (7.6 cm)
3" (7.6 cm)
1
"
(2.5 cm)
23 "
(60.6 cm)
24 in.
2
(155 cm2)
48 in.
2
(310 cm2)
1"*
(2.5 cm)
27¼"
(69.2 cm)
5"**
(12.7 cm)
7
8
Vent Length Chart
NOTE:
Side exhaust adds a 90° turn inside the washer/dryer. To determine maximum exhaust length, add one 90° turn to the chart.
No. of 90° turns or elbows
Type of Vent Box or
Louvered hoods
Angled hoods
0 Rigid metal
43 ft (13.1 m) 36 ft (11.0 m)
1 Rigid metal
33 ft (10.1 m) 26 ft (7.9 m)
2 Rigid metal
23 ft (7.0 m) 16 ft (4.9 m)
* Most installations require a
minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow.
A . Louvered hood style
B . Box hood style
4" (10.2 cm)
4" (10.2 cm)
A
B
4"
(10.2 cm)
2.5"
(6.4 cm)
Recommended hood styles
Angled hood style
is acceptable.
*Required spacing
**Rear clearance may be 0" (0 cm) when house exhaust system is lined up directly with dryer exhaust.