Whirlpool LTE5243DQ User Manual

min Twin
Washer*Dryer - 240 Volt
Installation Instructions
IMPORTANT: Read and save
these instructions.
IMPORTANT: Installer: Leave Installation Instructions
Homeowner: Keep Installation Instructions
for tuture reference,
Save Installation Instructions for locai
electrical inspector's use.

Before you start...

Your safety and the safety of others is very
important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This
A
messages will be preceded by the safety alert symbol and the word “DANGER" or "WARNING”. These words mean:
symbol alerts you to hazards that can k or hurt you and others. All safety

^WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from washer/dryer.
Failure to do so can result in death, explosion, or fire.
Location: Should be large enough to
fully open dryer door to 90°. See Panel G for "Recessed and closet installation instructions" and "Product dimensions."
Grounded electrical outlet within 5 feet of the center rear of cabinet is required, See "Electrical requirements."
Standpipe drain system:
Needs a two-inch diameter standpipe with minimum carry­away capacity of 17 gallons per minute. Top of standpipe must be at least 28 inches high and no higher than 48 inches from floor.
Floor drain system requires a siphon break. Part No. 285320, available from your authorized parts distributor.

ADANGER

You will be killed or seriously injured if you don’t follow instructions.

^WARNING

You ^ be killed or seriously injured if you don't follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Hot and cold
water faucets:
Must be within
4 feet of the
back of the washer/dryer and provide water pressure of5-100PSI.
Level floor:
1-inch maximum slope under entire washer/dryer.
Support: Floor must be sturdy enough to support washer/dryer weight, with water and clothes, of 375 pounds.
Do Not store or operate washer/dryer below 32°F (some water may remain in washer). Proper operation of dryer cycles requires temperatures above 45°F. See Use & Care Guide for “Winterizing” information.
Check code requirements: Some codes
limit or Do Not permit installation of washer/dryer in garages, closets, mobile homes and sleeping quarters. Contaot your local building inspector.
Check utilities: Proper water and electrical supply connections must be available,
Check location where washer/dryer will be installed. Proper installation is your responsibility. The washer/dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Make sure you have everything necessary for correct installation.
Water heater: Set to deliver 140°F water to the washer.
Laundry tub drain system: Needs a
20-gallon laundry tub. Top of tub must
be at least 28 inches high and no higher than 48 inches
from floor.
If a longer drain hose is
needed, drain hose (Part No,
388423) and hose extension kit (Part No. 285442) are
available from your
authorized parts
distributor.
Dryer may be exhausted
from the rear or left or right side.
Exhausting through the side requires Part No. 279823. See "Exhaust requirements," Panels C and D,
Four-inch metal exhaust vent is required. SEE RECESSED AREA INSTRUCTIONS ON
PANEL G.
Important: Observe all governing
codes and ordinances.

Tools and materials needed for installation:

utility knife
gloves
1/4" socket wrench
or nut driver
slip-joint pliers that open to
1-1/2" minimum

Electrical requirements

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A four-wire or three-wire, single-phase,
120/240-volt, 60-Hz, AC-only electrical
supply (or four-wire or three-wire,
120/208-volt, if specified on the model/serial rating plate) is required on a separate, 30-ampere circuit, fused on
both sides of the line. A time-delay fuse or circuit breaker is recommended, The
model/serial rating plate is located in the door well behind the dryer door on the front of the opening.
It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and in conformance with the National
Electrical Code, ANSI/NFPA 70 - latest
edition*, and all local codes and
ordinances,
Copies of the standards listed above may be
obtained from:
* National Fire Protection Association
Batterymarch Park Quincy, Massachusetts 02269
Power supply cord
Local codes may permit the use of a U.L.-listed, 120/240-volt minimum, 30­ampere, dryer power supply cord kit (pigtail). Power supply cord should be Type SRD or SRDT and be at least four feet long. The wires that connect to the dryer must end with ring terminals or spade terminals with upturned ends, A 3/4", U.L.-listed strain relief must be installed where the power supply cord connects to the washer/dryer (see
Figures 1 and 2).
Four-wire power supply cord
NEMA 14-30P
Figure 1
Panel A
spade terminals with upturned ends
This blade connected to this conductor.
ring terminals
I I
3/4" U.L.-listei strain relief
Three-wire power supply cord
NEMA 10-30P
Figure 2
NEUTRAL
(white or center)
For use where local codes permit use of flexible power supply cord.
A.

Four-wire connection...

four-wire
receptacle
(14-30R)
Figure 3
Four-wire installation is recommended (required for mobile homes); The power
supply cord must have four. No.-10 copper wires and match a four-wire receptacle of NEMA Type 14-30R (see Figure 3). The fourth wire (ground conductor) must be identified with a green cover and the neutrai conductor by a white cover.
Three-wire installation (if a four-wire system is not available): The power
supply cord must have three. No.-10 copper wires to match a three-wire receptacle of NEMA Type 10-30R (see Figure 4).
three-wire
receptacle
(10-30R)
Figure 4

Direct wire

The washer/dryer can be connected directly to fused disconnect or circuit breaker box with four-wire or three-wire flexible armored or non-metallic sheathed copper cable (with ground wire). Do Not use two-wire with bare ground wire. All current-carrying wires must be insulated.
A conduit connector must be installed at junction box, USE ONLY 10-GAUGE SOLID COPPER WIRE. DO NOT USE ALUMINUM WIRE. Allow four feet of slack in the line so dryer can be moved if servicing is ever necessary.

Electrical connection

C
-------
LT
terminal block cover
Figure 5
This dryer is manufactured with the cabinet-ground conductor connected to the NEUTRAL (center) of of the wiring harness at the terminal block, If local codes do NOT permit this type of connection, use "Four-wire connection" instructions.
GROUND INSTRUCTIONS: This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current,
If using power supply cord, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
If using a direct wire connection, this appliance must be connected to a grounded metal, permanent wiring system; or an equipment-ground conductor must be run with the circuit conductors and connected to the equipment-ground terminal or lead on the appliance,
WARNING - Improper connection of fhe equipment-ground conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

^WARNING

. Fire Hazard
Use a new UL approved 30 ampere power supply cord.
Use a UL approved strain relief. Disconnect power before making
electrical connections. Connect neutral wire (white or center
wire) to center terminal (silver). Ground wire (green or bare wire) must
be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in death,
fire, or electrical shock.

POWER SUPPLY CORD

neutral (white or center)
power supply cord ground wire (green)
Internal cabiriet ground connector

1. Disconnect the power supply.

2. Remove terminal block cover (see Figure 5).
3. Install copper, four-wire power supply cord through strain relief.
4. Remove the appliance harness ground wire (green with yellow stripes) from the internal ground connector and fasten under center, silver-colored terminal block screw.
5. Connect the ground wire (green) of the copper, four-wire power supply cord to the internal ground connector.
6. Connect the neutral wire (white) of the power supply cord to the center, silver-colored terminal screw of the terminal block. Connect the other wires to the outer terminals. Tighten screws
firmly,
7. Tighten strain relief screws.
8. Replace the terminal block cover.
center silver-colored terminal block screw
Figure 6
appliance harness ground wire (green with yellow stripes)
.external
cabinet­ground connector

^WARNING

A
Fire Hazard
Use 10 gauge solid copper wire. Use a UL approved strain relief. Disconnect power before making
electrical connections. Connect neutral wire (white or center
wire) to center terminal (silver). Ground wire (green or bare wire) must
be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death,
fire, or electrical shock.
DIRECT WIRE

1. Disconnect the power supply.

2. Remove terminal block cover (see Figure 5).
3. Strip 5 inches of outer covering from end of cable. Leave bare ground wire at 5 inches. Cut 1-1/2 inches from 3 remaining insulated wires. Strip insulation back 1 inch (see Figure 7).
10-gauge, 3-wire
with ground wire (Romex)
Direct wire preparation
Figure 7
u-shaped hook
r
Figure 8
4. Install copper, four-wire power supply cable through strain relief.
5. Remove fhe appliance harness ground wire (green with yellow stripes) from the internal ground connector and fasten under center, silver-colored terminal block screw.
6. Slide the hook end of the ground wire (bare) of fhe four-wire power supply cable under the internal ground connector screw. Squeeze hook end of wire together. Tighten screw.
7. Connect the neutral wire (white) of the power supply cable to the center, silver-colored terminal screw of the terminal block using the same method. Connect the other wires to the outer terminals. Tighten screws firmly.
8. Tighten strain relief screws.
9. Replace the terminal block cover.
Shape the end of each wire info a "U"
shaped hook (see
Figure 8). The bare
ground wire must be 4-1 /2 inches long after forming the hook.
led of