Whirlpool LPR 962, LPR 960, LPR 964 INSTALLATION

LPR 960/962/964 PRODUCT DESCRIPTION SHEET
GB IE
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Shaded circle Tap closed Large flame Maximum opening
delivery
Small flame Minimum opening or
reduced delivery
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame setting .
At the same time, press the push-button with a star . The spark plug gives out a spark that causes the burner to ignite.
If the burner does not ignite, press the push- button again.
5019 619 01096
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type o f ga s u se d
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6 G30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G31 37 mbar 4 gas 7.30 521 g/h 14.6
Typ e o f burner
large medium small
large medium small
large medium small
Appliance model
Injector marking 100/mm
Y115
H2 98
X72
87 65 50
87 65 50
Rated heat capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
min. rat. max.
ELECTRIC SUPPLY: 230-240V ~ 50 Hz
Gas pressure mbar
17 20 25
20 28-30 35
25 37 45
Air required for burning
3
m
/h
Loading...