Whirlpool GY395LXGB0, GY396LXGT4, GY396LXGQ2, GY396LXGQ0, GY396LXGB4 Installation Guide

...
Quick Reference
Panels
[]
Before you start Product dimensions
[] []
Cabinet dimensions/requirements
[]
Countertop preparation
[]
Electrical requirements
[][]
I Back cover I
I Back coverI I Sack coverI
If you need assistance:
Check your Use and Care Guide for a toll-free number to call or call the dealer from whom you purchased this appliance. The dealer is listed in the Yellow Pages of your phone directory under "Appliances -- Household -- Major -- Service and Repair."
Call when you: [] Have questions about range installation or operation.
[] Need to obtain the name and number of an authorized
servicecompany.
When you call, you will need:
Installation steps If range does not operate
If you need assistance/service Moving the range
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is
moved.
Failureto follow these instructions can result in
death or serious burns to children and adults.
[] The range model number. ,_ c_(_
[] The range serial number. -.J-- Both numbers are listed on the model/serial rating plate located on the
oven frame behind the storage drawer panel.
Your safety and the safety
of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. Thissymbol alerts you to hazards that can
kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word "DANGER" or
"WARNING". These words mean:
You wil_._Jlbe killed or seriously injured if you don't follow instructions.
36" (91.4 cm}
cooktop
height with
leveling legs lowered
1-112 turns
30-3/4" (78.1 cm)
cooktop width
22-1/,2"
(57.1 cm}
You can be killed or seriously injured if you don't follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the
instructions are not followed.
Important: Observe all governing codes and ordinances. Failure to meet codes and
ordinances could lead to fire or electrical shock. Proper installation isyour responsibility. A
qualified technician must install this range. Make sure you have everything necessary for correct installation. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the oven frame behind the storage drawer panel.
Check location where range will be installed.
The range should be located for convenient use in kitchen.
When installing a range under existing cabinets and the installation does not meet the minimum
cabinet clearances, install a range hood above the cooktop to avoid burn hazards.
ALL OPENINGS IN THE WALL OR FLOOR WHERE RANGE IS TO BE INSTALLED MUST BE SEALED.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum
clearances. Grounded electrical supply is required. See
"Electrical requirements," Panel B.
It is the customer's responsibility: To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 -- latest edition* and all local codes and ordinances.
1"
(2.5 cm
26-7/,8"
(68.2 cm
depth with
handle
he
e
18" {45,7 cm) _ _22-15/32" {57,1 cm)
upper cabinet __ _ opening depth
_cabinet opening width /'J_ " .....
3_ I "_. radius both _ "_
corners I 30-3/8" (77.2 cm)
4" (10.2 cm) _ _- rain, clearance ._r_,_" junction box - Do not
from both sides _J/'_ / 8" (20.3 cm( to seal range
of range to side _"f _ 22"' (55.9 cm) from cabinets
wall or other I I either cabinet, " combustible _ 7" (17.8 cm| max.
material from floor.
between upper /
countertop. _ I
cabinet and i' __E
_ / to sine
I .t I | 7/,8" (2.
_._ _ opening width
_ min. required
between cutout
.%
and cabinet door or hinge.
30" (76.2 cm)
25" (63.5 cm) countertop depth 24" (61 cm) base cabinet depth
36" (91.4 cm) countertop height When installed in a 24" (61 cm) base
cabinet with 25" (63.5 cm) countertop _ front of oven door
protrudes 1-7/8" (4.8 cm) beyond 24" (61 cm} base cabinet.
Note: 24" (61 cm) rain. when bottom
of wood or metal cabinet is protected by not less than 1/,4"
(0.64 cm) flame retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 ram} stainless steel, 0.024" (0.6 ram) aluminum or 0.020"' (0.5 mm)
copper. 30" (76.2 cm) rain. clearance
between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
The floor-mounted anti-tip bracket MUST be installed. To install the
anti-tip bracket shipped with the range, see Panel C and the anti-tip bracket templete/,instruction sheet.
Mobile home installation
The installation of this range must conform with
the Manufactured Home Construction and Safety Standard, -Stle 24 CFR, Part 3280
[formerly the Federal Standard for Mobile Home Construction and Safety, _tle 24, HUD (Part
280)] or, when such standard is not applicable, the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A*, or with local codes.
When this range is installed in a mobile home, it
must be secured to the floor during transit. Any method of securing the range is adequate as
long as it conforms to the standards listed
above.
Four-wire power supply cord or cable must be used in a mobile home installation. The
appliance wiring will need to be revised. See "Four-wire electrical connection," Panel B.
Copies of the standards listed may be obtained from',
* National Fire Protection Association
Batterymarch Park Quincy, Massachusetts 02269
The cooktop sides of the slide-in range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop and the opening width is 30-3/8" (77.2 cm), no
countertop preparation is required.
Formed front-edged countertops: Must have molded edge shaved flat 1/4" (0.64 cm) from each front corner of opening.
Tile countertops may need trim cut back
1/4" (0.64 cm) from each front corner and/or
rounded edge flattened.
30-318" (77.2
, ,_opening
1/,4"
(0.64 cm)
30-7/g"
.... },
Formed or tiled countertop trimmed 1/,4"
(0,64 cm) back at front
corners of countertop opening.
If countertop opening width is greater than 30-3/8" (77.2 cm), adjust the 1/4" (0.64 cm)
dimension. Countertop must be level. Place level on
countertop, first side to side; then front to back. If countertop is not level, range will not be level. Oven must be level for satisfactory baking
conditions.
Cooktop sides of range fit over edges of countertop opening.
level
fl screwdriver 3/8" and 5/16"
_:.\ 3/8" drive nut driver "
measuring _//_F--------._ ._
tape or ruler _'_
Panel A
safety glasses
"_" 1!8" drill bit
concretei,ceramic floors:
3/16" carbide-tipped
wo..oo,°
masonry drill bit (Hammer
may be needed for
anchors,)
channel lock
_2 plastic anchors
F_ 2 screws (#10 x 1-1/,2")
floor-mounted
anti-tip bracket Brackets must be securely mounted to sub-floor.
Thickness of flooring may require longer screws to
anchor bracket to sub-floor. Longer screws are available from your local hardware store.
Not shown: literature pack
Loading...