Whirlpool GXU7130DXS User Manual

PRODUCT MODEL NUMBERS
GXU7130DX
ELECTRICAL REQUIREMENTS
• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
VENTING REQUIREMENTS
Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x
25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.
30" (76.2 CM) Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10320576A
10/20/10
®
E
A
Page 1 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 6" (15.2 cm) or Larger Round Vent System
Vent Piece Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
6" (15.2 cm) or larger wall cap
0.0 ft (0.0 m)
3¹⁄₄" x 10" (8.3 cm x
25.4 cm) to 6" (15.2 cm) or larger
4.5 ft (1.4 m)
3¹⁄₄" x 10" (8.3 cm x
25.4 cm) to 6" (15.2 cm) or larger 90° elbow
5.0 ft (1.5 m)
PRODUCT DIMENSIONS
Example vent system
Maximum Recommended Length = 50 ft (15.2 m)
1 - 90° elbow 1 - wall cap 8 ft (2.4 m) straight
= 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m)
Length of 7" (17.8 cm) system = 13.0 ft (3.9 m)
Roof Venting Wall Venting
A
B
E
A
B
C
C
D
D
. 6" (15.2 cm) or larger round
vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent through roof
B. Round vent: use 6" (15.2 cm)
or larger round damper (purchased separately)
C. Round vent: use 3¹⁄₄" x 10"
(8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)
D. 27" (68.6 cm) - 30" (76.2 cm)
above gas cooking surface 24" (61.0 cm) - 30" (76.2 cm) above electric cooking surface
E. Roof cap
A. 6" (15.2 cm) or larger round
vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent through the wall
B. Round vent: use 3¹⁄₄" x 10" (8.3
x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)
C. 3¹⁄₄" x 10" (8.3 x 25.4 cm)
through the wall
D. 27" (68.6 cm) - 30" (76.2 cm)
above gas cooking surface 24" (61.0 cm) - 30" (76.2 cm) above electric cooking surface
E. Wall cap
90˚ elbow
6 ft (1.8 m)
2 ft (0.6 m)
Wall cap
1³⁄₄"
(4.4 cm)
4³⁄₄"
(12.1 cm)
³⁄₄"
(2.0 cm)
29¹⁵⁄₁₆" (76.0 cm)
4¹⁄₁₆" (10.3 cm)
1¹⁄₂"
(3.8 cm)
9"
(22.9 cm)
20"
(50.8 cm)
1"
(2.5 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10320576A
10/20/10
INSTALLATION CLEARANCES
Page 2 of 2
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3¹⁄₄" x 10" (8.3 cm x
25.4 cm) 90° elbow
5.0 ft (1.5 m)
3¹⁄₄" x 10" (8.3 cm x
25.4 cm) flat elbow
12.0 ft (3.7 m)
3¹⁄₄" x 10" (8.3 cm x
25.4 cm) wall cap
0.0 ft (0.0 m)
Example vent system
Maximum Recommended Length = 35 ft (10.7 m)
1 - 90° elbow 8 ft (2.4 m) straight 1 - wall cap
= 5.0 ft (1.5 m) = 8.0 ft (2.4 m) = 0.0 ft (0.0 m)
Length of 3¹⁄₄" x 10" (8.3 cm x
25.4 cm) system
= 13.0 ft (3.9 m)
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
2 ft
(0.6 m)
elbow
6 ft (1.8 m)
Wall cap
C
B
D
A
E
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop B. 24" (61.0 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces 30" (76.2 cm) suggested max. - bottom of range hood to
cooking surface C. 30" (76.2 cm) min. cabinet opening width D. 13" (33.0 cm) cabinet depth E. 36" (91.4 cm) base cabinet height