* NOTE: 24" (61 cm) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (6 mm) flame retardant mill-board covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) min. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
Do not pinch the power supply cord between the range and the wall.
Do not seal the range to the side cabinets.
2" (5.1 cm) min. countertop space to side wall or other combustible material
This shaded area recommended for installation of rigid gas pipe.
Flexible gas pipe and electrical outlet are recommended in either shaded area.
18" (45.7 cm) min. clearance upper cabinet to countertop
13" (33 cm) max. upper cabinet depth
If cabinet depth is greater than 24" (61 cm), oven frame must extend beyond cabinet fronts by 1/2" (13 mm) min.
30-1/8" (76.5 cm) opening width
30" (76.2 cm) min. cabinet opening width
8"
(20.3 cm)
8"
(20.3 cm)
4-1/2" (11.4 cm)
4-1/2" (11.4 cm)
2" (5.1 cm)
17" (43.2 cm)
®
30" Freestanding Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
GS440LEM GS445LEM
SF369LEM SF379LEM SF380LEM
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Gas supply: Use 3/4" rigid pipe gas supply line to the range location. A smaller size pipe on long runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" minimum. If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, 1/2-inch or 3/4-inch I.D., be used for connecting the range to the rigid gas supply line. A 1/2" male pipe thread is needed for connection to pressure regulator female pipe threads. An easily accessible individual manual shutoff valve must be located in the same room, but external to the range.
Electrical: A 120-volt, 60 Hz, AC-only, 10 amp, electrical supply fused on both sides of the line. A separate circuit is recommended. A time-delay fuse or circuit breaker is recommended.
Ref. 9758659
10-04-04
Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C).
Use an insulated pad or 1/4" (6 mm) plywood under range if installing range over carpeting.
29-7/8" (75.9 cm) width
46-7/8" (119.1 cm) overall height
25" (63.5 cm)
36" (91.4 cm) cooktop height
27-1/8” (68.9 cm) depth with handle
8
8 8