* NOTE: 24" (61 cm) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (6 mm) flame
retardant mill-board covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) min. clearance between the top of the
cooking platform and the bottom of an unprotected wood
or metal cabinet.
For minimum
clearance to top of
cooktop, see NOTE.*
Do not pinch the power
supply cord between the
range and the wall.
Do not seal the range to
the side cabinets.
2" (5.1 cm) min.
countertop
space to side
wall or other
combustible
material
This shaded area recommended
for installation of rigid gas pipe.
Flexible gas pipe and electrical
outlet are recommended in
either shaded area.
18" (45.7 cm)
min. clearance
upper cabinet to
countertop
13" (33 cm) max.
upper cabinet depth
If cabinet depth is greater
than 24" (61 cm), oven
frame must extend beyond
cabinet fronts by 1/2"
(13 mm) min.
30-1/8" (76.5 cm)
opening width
30" (76.2 cm) min.
cabinet opening width
8"
(20.3 cm)
8"
(20.3 cm)
4-1/2"
(11.4 cm)
4-1/2"
(11.4 cm)
2" (5.1 cm)
17" (43.2 cm)
®
30" Freestanding Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
GS440LEM
GS445LEM
SF369LEM
SF379LEM
SF380LEM
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Gas supply: Use 3/4" rigid pipe gas supply line
to the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by AGA or CSA, 1/2-inch or
3/4-inch I.D., be used for connecting the range to
the rigid gas supply line. A 1/2" male pipe thread is
needed for connection to pressure regulator
female pipe threads. An easily accessible individual
manual shutoff valve must be located in the same
room, but external to the range.
Electrical: A 120-volt, 60 Hz, AC-only,
10 amp, electrical supply fused on both sides of
the line. A separate circuit is recommended. A
time-delay fuse or circuit breaker is recommended.
Ref. 9758659
10-04-04
Contact a qualified floor
covering installer to check that
the floor covering can withstand
at least 200°F (93°C).
Use an insulated pad or 1/4"
(6 mm) plywood under range if
installing range over carpeting.