Whirlpool GI1500XHW7, GI1500XHW6 Owner’s Manual

ICE MAKER
For questions about features, operation/performance,
parts, accessories or service, call: 1-800-253-1301.
In Canada, call for assistance 1-800-461-5681, for installation
www.whirlpool.com or www.whirlpoolappliances.ca
and service, call: 1-800-807-6777
or visit our website at...
MACHINEAGIA(_ONS
Table of Contents/Table des matieres .................. 2
installation ou service, le 1-800-807-6777
ou visitez notre site web h
www,whirlpoola pplia nces.ca
2217406A
TABLEOFCONTENTS
TABLEDESMATIERES
ICE MAKER SAFETY ...................................................................... 2
INSTALLATION INSTRUCTIONS .................................................. 3
Unpack the Ice Maker .................................................................. 3
Location Requirements ................................................................ 3
Electrical Requirements ............................................................... 4
Water Supply Requirements ........................................................ 4
Leveling ........................................................................................ 4
Connect Water Supply ................................................................. 4
Drain Connection ......................................................................... 6
Ice Maker Door ............................................................................. 7
Normal Sounds ............................................................................ 8
ICE MAKER USE ............................................................................ 8
How Your Ice Maker Works ......................................................... 8
Using the Controls ....................................................................... 9
ICE MAKER CARE .......................................................................... 9
Cleaning ........................................................................................ 9
Vacation and Moving Care ......................................................... 11
TROUBLESHOOTING .................................................................. 12
Ice Maker Operation ................................................................... 12
Ice Production ............................................................................ 12
Ice Quality ................................................................................... 12
Plumbing Problems .................................................................... 12
ASSISTANCE OR SERVICE ......................................................... 13
In the U.S.A................................................................................ 13
In Canada ................................................................................... 13
WARRANTY .................................................................................. 14
SI_CURITI_ DE LA MACHINE .h,GLAQONS ................................ 15
INSTRUCTIONS D'INSTALLATION ............................................. 15
Deballage de la machine & glagons ........................................... 15
Exigences d'emplacement ......................................................... 15
Specifications electriques .......................................................... 16
Specifications de ralimentation en eau ..................................... 16
Nivellement ................................................................................. 16
Raccordement de la canalisation d'eau .................................... 17
Raccordement au conduit d'evacuation .................................... 18
Porte de la machine a glagons ................................................... 19
Sons normaux ............................................................................ 20
UTILISATION DE LA MACHINE .&GLAQONS ............................ 21
Fonctionnement de la machine a glagons ................................ 21
Utilisation des commandes ........................................................ 21
ENTRETIEN DE LA MACHINE .&GLAQONS .............................. 21
Nettoyage ................................................................................... 21
Precautions a prendre avant lesvacances
ou dem6nagement ..................................................................... 24
DI_PAN NAG E................................................................................. 24
Fonctionnement de la machine &glagons ................................. 24
Production de glagons ............................................................... 25
Qualite des glagons .................................................................... 25
Problemes de plomberie ............................................................ 25
ASSISTANCE OU SERVICE ......................................................... 26
GARANTIE ..................................................................................... 27
ICEMAKERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
2
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury when using your ice maker, follow these basic
precautions:
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Disconnect power before cleaning.
Disconnect power before servicing.
Replace all parts and panels before operating.
Use two or more people to move and install ice maker.
SAVE THESE INSTRUCTIONS
INSTALLATIONINSTRUCTIONS
To ensure proper ventilation for your ice maker, the front side
must be completely unobstructed. The unit may be closed-in on the top and 3 sides, but the installation should allow the
Excessive Weight Hazard
Use two or more people to move and install ice maker. Failure to do so can result in back or other injury.
Removing Packaging Materials
Remove tape and glue from your ice maker before using.
To remove any remaining tape or glue, rub the area briskly with your thumb. Tape or glue residue can also be easily removed by rubbing a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.
Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your ice maker.
ice maker to be pulled forward for servicing if necessary.
Installation of the ice maker requires a cold water supply inlet of 1/4"(6.35 mm) OD soft copper tubing with a shutoff valve
and either a gravity-drain system or condensate pump to carry the water to an existing drain.
Choose a well ventilated area with temperatures above 55°F (13°C) and below 100°F (38°C). Best results are obtained between 70°F (21°C) and 90°F (32°C).
This unit must be installed in an area protected from the elements, such as wind, rain, water spray, or drip.
When installing the ice maker under a counter, follow the recommended opening dimensions shown. Place electrical and plumbing fixtures in the recommended location as
shown. NOTE: Do not kink or pinch the power supply cord between
the ice maker and cabinet.
Cleaning Before Use
After you remove all of the packaging materials, clean the inside of your ice maker before using it. See the cleaning instructions in
the "Ice Maker Care" section.
A
34"
(86.4 cm)
Min,
341/2''
(87.6 cm)
Max.
cm)
281/2"
(72.4 cm)
B
1
(38.1 cm)
A. Recommended location for electrical
and plumbing fixtures
B.Floor level
You should choose a location where the floor is even. It is important for the ice maker to be level in order to work
properly. If needed, you can adjust the height of the ice maker by changing the height of the leveling legs. See "Leveling."
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your ice maker into its final location, it is important to make sure you have the proper electrical
connection: A 115 Volt, 60 Hz., AC only 15-amp electrical supply, properly
grounded in accordance with the National Electrical Code and local codes and ordinances, is required.
It is recommended that a separate circuit, serving only your ice maker, be provided. Use a receptacle which cannot be turned off by a switch or pull chain.
Recommended grounding method For your personal safety, this appliance must be grounded. This
appliance is equipped with a power supply cord having a 3 prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong, grounding-type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility of the customer to have a properly grounded, 3 prong wall receptacle installed by a qualified electrician.
A cold water supply with water pressure of between 30 and 120 psi (207 - 827 kPa) is required to operate the ice maker. If you have questions about your water pressure, call a licensed, qualified plumber.
Reverse Osmosis Water Supply IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the ice maker needs to be between 30 and 120 psi (207 - 827 kPa).
If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 to 60 psi (276 - 414 kPa). The reverse osmosis system must provide 1 gal (3.79L) of water per hour to the ice maker for proper ice maker operation.
If the water pressure to the reverse osmosis system is less than 40 to 60 psi (276 - 414 kPa):
Check to see whether the sediment filter in the reverse osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill after heavy usage.
If you have questions about your water pressure, call a licensed, qualified plumber.
It is important for the ice maker to be level in order to work properly. Depending upon where you install the ice maker, you may need to make several adjustments to level it. You may also use the leveling legs to lower the height of the ice maker for
undercounter installations. Tools needed: Gather the required tools and parts before starting installation.
Carpenter's level
Adjustable wrench NOTE: It is easier to adjust the leveling legs if you have another
person to assist you.
1. Move the ice maker to its final location. NOTE: If this is a built-in installation, move the ice maker as
close as possible to the final location.
2. Place a carpenter's level on top of the product to see if the ice maker is level from front to back and side to side.
3. Push up on the top front of the ice maker, and then locate the leveling screws that are on the bottom front of the ice maker.
4. Using an adjustable wrench, change the height of the legs as follows:
Turn the leveling leg to the right to lower that side of the
ice maker.
Turn the leveling leg to the left to raise that side of the ice
maker.
NOTE: The ice maker should not wobble. Use shims to add stability when needed.
5. Push up on the top rear of the ice maker and locate the leveling legs that are on the bottom rear of the ice maker.
6. Follow the instructions in Step 4 to change the height of the legs.
7. Use a carpenter's level to recheck the ice maker to see that it is even from front to back and side to side. If the ice maker is
not level, repeat steps 3 to 6. If the ice maker is level, go to the "Connect Water Supply" section.
Read all directions thoroughly before you begin. IMPORTANT:
Plumbing shall be installed in accordance with the International Plumbing Code and any local codes and
ordinances.
Use copper tubing and check for leaks.
Install copper tubing only in areas where temperatures will remain above freezing.
Tools needed:
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Flat-blade screwdriver 7/le"and 1/2"open-end wrenches or two adjustable wrenches
1/4"nut driver 1/4"drill bit
Hand drill or electric drill properly grounded
NOTE: Your ice maker dealer has a kit available with a 1/4" (6.35 mm) saddle-type shutoff valve, a union, and copper tubing.
Before purchasing, make sure a saddle-type valve complies with your local plumbing codes. Do not use a piercing-type or 3Ae" (4.76 mm) saddle valve which reduces water flow and clogs more easily.
Connecting the water line
1. Turn off main water supply. Turn on nearest faucet long enough to clear line of water.
2. Find a 1/2"(12.70 mm) to 1V4" (3.18 cm) vertical cold water pipe near the ice maker.
NOTE: Horizontal pipe will work, but the following procedure must be followed: Drill on the top side of the pipe, not the bottom. This will help keep water away from the drill. This also keeps normal sediment from collecting in the valve.
3. Using a grounded drill, drill a 1/4"(6.35 mm) hole in the cold water pipe you have selected.
4. Fasten shutoff valve to cold water pipe with pipe clamp. Be sure outlet end is solidly in the 1/4"(6.35 mm) drilled hole in the water pipe and that washer is under the pipe clamp. Tighten packing nut. Tighten the pipe clamp screws carefully and evenly so washer makes a watertight seal. Do not overtighten
the pipe clamp or you may crush cold water pipe if it is soft copper tubing. Do not use a piercing-type or 3/le" (4.76 mm)
saddle-type valve which reduces water flow and clogs more easily.
5. Now you are ready to connect the copper tubing. Use 1/4" (6.35 mm) OD soft copper tubing for the cold water supply.
Ensure that you have the proper length needed for the
job. Be sure both ends of the copper tubing are cut square.
Slip compression sleeve and compression nut on copper
tubing as shown. Insert end of tubing into outlet end squarely as far as it will go. Screw compression nut onto outlet end with adjustable wrench. Do not overtighten.
6.
Place the free end of the tubing into a container or sink, and turn on main water supply and flush out tubing until water is clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final connection to the inlet of the water valve to prevent possible
water valve malfunction.
7. Bend the copper tubing to meet the water line inlet which is located on the back of the ice maker cabinet as shown.
REAR VIEW
A. Drain hose (drain pump models only) B. Vent hose (drain pump models only) C. Water supply fine
8.
Thread the nut onto the coupling on the end of the copper tubing. Tighten the nut by hand. Then tighten it with a wrench two more turns. Do not overtighten.
NOTE: To prevent rattling, be sure the copper tubing does not touch the cabinet's side wall or other parts inside the
cabinet.
A B C D E F
A.Line to ice maker D.Coupling (purchased) B.Nut (purchased) E.Ferrule (purchased) C.Ferrule(purchased) F Nut (purchased)
9. Turn shutoff valve ON.
10. Check for leaks. Tighten any connections (including connections at the valve) or nuts that leak.
H ..........i..........B
A. Cold water pipe B. Pipe clamp C. Copper tubing D. Coupfing (purchased)
E. Compression nut F Compression sleeve
G. Shutoff valve H. Packing nut
Gravity Drain System
Connecting the Drain
Connect the ice maker drain to your drain in accordance with all state and local codes and ordinances. If the ice maker is
provided with a gravity drain system, follow these guidelines when installing drain lines. This will prevent water from flowing back into the ice maker storage bin and potentially flowing onto the floor causing water damage.
Drain lines must have a minimum of 5/8"(15.88 mm) inside diameter.
Drain lines must have a 1" drop per 48" (2.54 cm drop per 122 cm) of run or 1/4"drop per 12" (6.35 mm per 30.48 cm) of run and must not have low points where water can settle.
The floor drains must be large enough to accommodate drainage from all drains.
The ideal installation has a standpipe with a 1W' (3.81 cm) to 2" (5.08 cm) PVC drain reducer installed directly below the
outlet of the drain tube as shown. You must maintain a 1" (2.54 cm) air gap between the drain hose and the
standpipe.
It may be desirable to insulate the drain line thoroughly up to the drain inlet.
SIDE VIEW
I
I I
After ensuring that the drain system is adequate, follow these steps to properly place the ice maker:
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Plug ice maker into a grounded 3 prong outlet.
Excessive Weight Hazard
Use two or more people to move and install ice maker. Failure to do so can result in back or other injury.
35/8 II
(9.2 cm)
(58.4 cm)
2-.11/2 ''
(5 cm - 3.8 cm)
A. Drain hose B. 1" (2.54 cm) air gap
C. PVC drain reducer D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the 3/4"(1.91 cm) panel on the door. The drain should also be centered from left to right (7_" [18.56 cm] from either side of the ice maker).
Drain Pump System (on some models)
Connect the ice maker drain to your drain in accordance with the International Plumbing Code and any local codes and
ordinances. NOTE: If the drain hose becomes twisted and water cannot
drain, your ice maker will not work.
2. Style 1 - For gravity drain system, push the ice maker into position so that the ice maker drain tube is positioned over the PVC drain reducer. See "Gravity Drain System" earlier in this section. Style 2 - For drain pump system connect the drain pump outlet hose to the drain. See "Drain Pump System" earlier in this section.
3. Recheck the ice maker to be sure that it is level. See "Leveling."
4. If it is required by your local sanitation code, seal the cabinet to the floor with an approved caulking compound after all
water and electrical connections have been made.
6
TOOLS NEEDED: Gather the required tools and parts before starting installation.
5/le"wrench Flat putty knife
1/4"wrench Phillips screwdriver
Hinge pin 5_6" Hex-head hinge screw
Handlescrew
End Cap screw
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
6. Replace the upper access panel loosely on the ice maker.
7. Reverse the door endcaps as follows:
Remove both the screws and endcaps (top and bottom).
Move the top end cap diagonally to the opposite side's bottom corner, keeping the straight side of the end cap
facing the front of the ice maker.
Move the bottom end cap diagonally to the opposite side's top corner, keeping the straight side of the end cap facing the front of the ice maker.
8. Set the door aside.
Reverse Hinges
1. Unscrew and remove the top hinge. Replace the screws in the empty hinge holes.
2. Remove the screws from the bottom of the opposite side of the ice maker cabinet. Turn the top hinge upside down so that the hinge pin points up. Place the hinge on the bottom opposite side of the ice maker and tighten screws.
3. Remove the plastic hinge pin sleeve from the "old" bottom hinge and replace it on the new bottom hinge pin.
4. Remove the "old" bottom hinge screws and hinge. Replace the screws in the empty hinge holes.
5. Remove the screws from the top of the opposite side of the ice maker cabinet. Turn the hinge upside down so that the hinge pin points down.
6. Raise the upper access panel and place the hinge on the top opposite side of the ice maker. Tighten the hinge screws.
7. Remove the top hinge pin.
Replace Door
Remove door
1. Unplug ice maker or disconnect power.
2. Remove the handle screws and handle (on some models). Keep the parts together and set them aside.
3. Remove the two hex-head screws from the upper access panel. Lift up on the bottom of the access panel to release it
from the front of the ice maker. Do not disconnect the wires.
4. With the upper access panel raised, remove the hinge pin from the top hinge.
5. Remove the door from the hinges and screw the top hinge pin back into the top hinge.
1. Place plastic hinge pin sleeve in the top hinge hole on the door. Align the door with the top hinge hole and replace the top hinge pin.
2. Replace the upper access panel and secure it with the hex head screws.
3. Replace the handle and handle screws.
Top Hinge
A
I
B C
D
A. Hinge pin B. Hinge pin sleeve C. Hinge D. Hex-head hinge screw
Bottom Hinge
L
A. Hex-head hinge screw B. Hinge pin sleeve C. Hinge D. Hinge pin
ICEMAKERUSE
When you first start your ice maker, the water pan will fill and the system will rinse itself before starting to make ice. The rinsing process takes about 5 minutes.
Under normal operating conditions, the ice maker will cycle at preset temperatures. The ice level sensor located in the ice storage bin will monitor the ice levels.
IMPORTANT:
If the water supply to the ice maker is turned off, be sure to set the ice maker control to OFF.
The ice maker is designed to make clear ice from the majority of water sources on a daily basis. If your results are unsatisfactory, your water may need to be filtered or treated.
Reverse Door Catch:
1. Remove the hole plugs from the opposite side of the door and set aside.
2. Remove the screws from the magnetic door catch and replace it on the opposite side of the door.
3. Push the hole plugs into place on the opposite side of the door.
4. Plug in ice maker or reconnect power.
Your new ice maker may make sounds that are not familiar to you. Because the sounds are new to you, you might be
concerned about them. Most of the new sounds are normal. Hard surfaces such as floors, walls and cabinets can make the sounds
seem louder than they actually are. The following describes the kinds of sounds that might be new to you and what may be making them.
You will hear a buzzing sound when the water valve opens to fill the water reservoir for each cycle.
Rattling noises may come from the flow of the refrigerant or the water line. Items stored on top of the ice maker can also
make noises.
The high-efficiency compressor may make a pulsating or high pitched sound.
Water running over the evaporator plate may make a splashing sound.
Water running from the evaporator plate to the water reservoir may make a splashing sound.
As each cycle ends, you may hear a gurgling sound due to the refrigerant flowing in your ice maker.
You may hear air being forced over the condenser by the condenser fan.
During the harvest cycle, you may hear a "thud" when the ice sheet slides from the evaporator onto the cutter grid.
When you first start the ice maker, you may hear water running continuously. The ice maker is programmed to run a rinse cycle before it begins to make ice.
The Ice Making Process
1. Water is constantly circulated over a freezing plate. As the water freezes into ice, the minerals in the water are rejected. This produces a clear sheet of ice with a low mineral content.
2= When the desired thickness is reached, the ice sheet is
released and slides onto a cutter grid. The grid divides the sheet into individual cubes.
3. The water containing the rejected minerals is drained after each freezing cycle.
4. Fresh water enters the machine for the next ice making cycle.
8
5.
Cubes fall into the storage bin. When the bin is full, the ice maker shuts off automatically and restarts when more ice is needed. The ice bin is not refrigerated, and some melting will occur. The amount of melting varies with room temperature.
NOTE: As the room and water temperatures vary, so will the amount of ice produced and stored. This means that higher operating temperatures result in reduced ice production.
1. To start the normal ice making cycle, select ON.
2. To stop ice maker operation, select OFE
CLEANING
Ice Maker System
Minerals that are removed from water during the freezing cycle will eventually form a hard scaly deposit in the water system. Cleaning the system regularly helps remove the mineral scale buildup. How often you need to clean the system depends upon how hard your water is. With hard water of 15 to 20 grains/gal. (4 to 5 grains/liter), you may need to clean the system as often as every 6 months.
NOTE: Use one 16 oz (473 mL) bottle of approved ice maker cleaner. To order, call 1-800-442-9991 and ask for Part Number
8171307. In Canada, call 1-800-807-6777.
1. Push the selector switch to OFR
2. Wait 5 to 10 minutes for the ice to fall into the storage bin. Remove all ice from the storage bin.
3. Unscrew the drain cap from the bottom of the water pan located inside the storage bin as shown. Allow the water to drain completely.
4. Replace the drain cap securely on the water pan. If the drain cap is loose, water will empty from the water pan and you will
have either thin ice or no ice.
5. Read and follow all handling information on the cleaner bottle before completing the steps below. Use one 16 oz (473 mL) bottle of approved ice maker cleaner.
6. Pour one bottle of solution into the water pan. Fill the bottle twice with tap water and pour it into the water pan.
NOTE: The CLEAN setting is used whenever solutions are circulated through the ice maker for cleaning. Only the water pump and compressor operate at this setting. See the "Ice Maker System" section.
ICEMAKERCARE
The ice making system and the air cooled condenser need to be cleaned regularly for the ice maker to operate at peak efficiency and to prevent premature failure of system components. See the "Ice Maker System" and the "Condenser" sections.
Exterior Surfaces
Wash the exterior enamel surfaces and gaskets with warm water and mild soap or detergent. Wipe and dry. Regular use of a good household appliance cleaner and wax will help protect the finish. Do not use abrasive cleaners on enamel surfaces as they may
scratch the finish. For products with a stainless steel exterior, use a clean sponge or
soft cloth and a mild detergent in warm water. Do not use abrasive or harsh cleaners.
I-I%
A
B
A. Water pan
B.Drain cap
7. Push the selector switch to CLEAN. (See the "Using the Controls" section.) The light will turn on, indicating that the
cleaning cycle is in process. When the indicator light turns off (approximately 45 minutes), the cleaning cycle is complete.
During the cleaning cycle, the system will both clean and rinse itself.
8. After the cleaning cycle is complete, remove the drain cap from the water pan to see if any cleaning solution is left in the water pan. If cleaning solution drains from the water pan, you should run the clean cycle again. Be sure to replace the drain cap securely on the water pan. If the drain cap is loose, water will empty from the water pan and you will have either thin ice
or no ice.
NOTE: Severe scale buildup may require repeated cleaning with a fresh quantity of cleaning solution.
9. Push the selector switch to ON to resume ice production.
Loading...
+ 19 hidden pages