Whirlpool GHW9300PW, GHW9300P Dimension Guide

®
Duet Washer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
DRAIN SYSTEM OPTIONS
GHW9300P
Electrical: 120-volt, 60 Hz, AC-only, 15 or 20 amp electrical supply. A time-delay fuse or circuit breaker and separate circuit is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8182307
01-05-05
UNDERCOUNTER INSTALLATION
(
)
( )
6
m
Washer on Pedestal
Dimensions shown are for minimum spacing.
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of 2 in. (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30 in. (76.2 cm) high and no higher than 96 in. (2.4 m) from the bottom of the washer.
Laundry tub drain system (view 1)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 30 in. (76.2 cm) above the floor.
Floor drain system (view 2)
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28 in. (71 cm) from the bottom of the washer. Additional hoses might be needed.
*Min. top and
bottom air openings for closet door.
**External exhaust
elbow requires additional space.
***Wall, door amd
floor molding may require additional spacing.
Stacked Washer and Dryer
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
RECESSED AREA AND CLOSET INSTALLATIONS
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required (view 2). Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
(7.6 cm)
(7.6 cm)
1"
(2.5 cm)
(
86.4
31 ¹⁄₂ "
(80 cm)
34
"
cm)
4"
(10.2 cm)
2
48 in.
(310 cm
2
24 in.
(155 cm
*
2
)
*
2
)
AB
A. Side view - closet or confined area B. Closet door with vents
"
"
1"
(2.5 cm)
27"
(68.6 cm)
48 in.2 *
(310 cm
2
)
39" min
(99.0 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
24 in.
155 cm
2
*
2
18 min."
(45.7 cm)
31¹⁄₂ "
1"
(2.5 cm)
1"
(2.5 cm)
(80 cm)
4"
(10.2 cm)
3" (7.6 cm)
3" (7.6 cm)
1" (2.5 cm)
27"
50¹⁄₂ "
(128.3 cm)
(68.6 cm)
31¹⁄₂ "
(80.0 cm)
38"
(96.5 cm)
5¹⁄₂ "**
(14 cm)
7" (17.8 cm)
7" (17.8 cm)
4"
(1
0.2 cm
" (15.2 cm)
76"
193 cm)
1"***
(2.5 cm)
31¹⁄₂"
)
27"
(68.6 cm)
1"
(2.5 cm)1"(2.5 cm)
(2.5 c
1"***
9" (22.9 cm)
27"
1"
(2.5 cm)
30" min.
(76.2 cm)
1
2
28" min.
30" min.
(76.2 cm)
(71 cm)
12
Loading...