MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
This product is suitable for use above electric or gas cooking products up to 36" (91.4 cm) wide.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the
illustration in these installation instructions.
COMBINAClON MICROONDAS CAMPANA
INSTRUCClONES DE INSTALAClON
Este producto puede usarse encima de productos para cocci6n el6ctricos o a gas de 36" (91,4 cm) de ancho o menor.
Estas instrucciones de instalaci6n cubren diferentes modelos. La apariecia de su modelo en particular puede ser
ligeramente diferente de la ilustraci6n en estas instrucciones de instalaci6n.
TableofContents / [ndice
MICROWAVE OVEN SAFETY ................................................... 2
VENTING DESIGN SPECIFICATIONS ..................................... 2
INSTALLATION REQUIREMENTS ........................................... 3
Tools and Parts ....................................................................... 3
Location Requirements .......................................................... 4
Product Dimensions ............................................................... 4
Electrical Requirements .......................................................... 5
INSTALLATION INSTRUCTIONS ............................................. 5
Remove Mounting Plate ......................................................... 5
Rotate Air Deflector ................................................................ 5
Locate Wall Stud(s) ................................................................. 7
Mark Rear Wall ....................................................................... 8
Drill Holes in Rear Wall ........................................................... 8
Attach Mounting Plate to Wall ................................................ 9
Prepare Upper Cabinet ........................................................... 9
Install Damper Assembly ...................................................... 10
Install the Microwave Oven .................................................. 10
Complete Installation ............................................................ 12
ASSISTANCE ........................................................................... 12
Replacement Parts ............................................................... 12
Accessories ........................................................................... 12
SEGURIDAD DE LA COMBINACION MICROONDAS CAMPANA...13
ESPECIFICACIONES PARA EL DISEI_IO DE LA VENTILACION ......13
REQUISITOS DE INSTALACION ......................................................... 15
Piezas y herramientas ........................................................................ 15
Requisitos de ubicaci6n ..................................................................... 15
Deminsiones del producto ................................................................. 16
Requisitos el_ctricos .......................................................................... t 6
INSTRUCCIONES DE INSTALACI(SN ................................................. 17
Retire la placa de montaje ................................................................. 17
Rote el desviador de aire ................................................................... 17
Ubique el(los) pie(s) derecho(s) de pared .......................................... t 9
Marque la pared posterior ................................................................. 20
Taladrar oriticios en la pared posterior .............................................. 20
Ajuste la placa de montaje a la pared ............................................... 21
Preparaci6n del gabinete superior ..................................................... 22
Instale el ensamblaje de la compuerta de tiro ................................... 22
Instalaci6n del homo de microondas ................................................ 22
Complete la instalaci6n ...................................................................... 24
ASISTENCIA .......................................................................................... 24
Refacciones ....................................................................................... 24
Accesorios .......................................................................................... 24
IMPORTANT: Read Installation Instructions thoroughly before beginning installation. Save Installation Instructions for local house
inspector's use.
IMPORTANTE: Lea las instrucciones de instalaci6n a fondo antes de cornenzar la instalaci6n. Guarde las instrucciones para el uso del
inspector local de la casa.
8205139
MICROWAVE OVEN SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
VENTING DESIGN SPECIFICATIONS
This section is intended for architectural designer and builder/contractor reference only.
NOTES:
• Vent materials needed for installation are not provided with
microwave hood.
We do not recommend using a flexible metal vent.
Toavoid possible product damage, be sure to vent air outside,
unless using ventless (recirculating) installation. Do not vent
exhaust air into concealed spaces, such as spaces within
walls or ceilings, attics, crawl spaces or garages.
For optimal venting installation, we recommend:
• using roof or wall caps that have back draft dampers
• using a rigid metal vent
• using the most direct route by minimizing the length of the
vent and number of elbows to provide efficient performance
• using uniformly sized vents
• using duct tape to seal all joints in the vent system
• using caulking compound to seal exterior wall or roof opening
around cap
• not installing 2 elbows together, for optimal hood performance
If venting through the wall, be sure that there is proper clearance
within the wall for the damper to open fully.
If venting through the roof, and rectangular to round transition is
used, be sure there is at least 3" (7.6 cm) of clearance between
the top of the microwave oven and the transition piece. See
"Rectangular to Round Transition" illustration.
Roof venting
Wall venting
Roof cap
Wall cap
Rectangular to Round Transition
NOTE: The minimum 3" (7.6 cm) clearance must exist between
the top of the microwave oven and the rectangular to round
transition piece so that the damper can open freely and fully.
B
C
E
3" (7.6 cm)
F
t
A. Roof cap
B. 6" (15.2 crn) min. diameter round vent
C. Elbow (for wall venting only)
D. Wall cap
E. 3 _" x 10" to 6" (8.3 x 25.4 cm to 15.2 crn)
rectangular to round transition piece
F Vent extension piece, at least 3" (7.6 cm) high
Recommended Standard Fittings
31/4'' x 10" (8.3 x 25.4 cm) vent system = 73ft (22.2 m) total
A B
6 ft (1.8 m) _{ N
2 ft
(0.6
A. One 3 _" x 10" (8.3 x 25.4 crn) 90 ° elbow = 25 ft (7.6 m)
B. 1wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
6" (15.2 cm) vent system = 73 ft (22.2 m) total
B
_,( 6 ft (1.8 m)
The following length equivalents are for use when figuring vent
length. See the examples in "Recommended Vent Length" later in
this section.
A B C
E F G
A. Rectangular to round transition piece: 3 _" x 10" to 6" = 5 ft
(8.3 x 25.4 cm to !5.2 cm = 1.5 rn)
B. Roof cap: 3 ¼" x 10" =24 ft (8.3 x 25.4 cm = 7.3 m)
C. 90° elbow: 3_" x 10" =25 ft (8.3 x 25.4 cm = 7.6 m)
D. 90 ° elbow: 6" = !0 ft (15.2 cm = 3 rn)
E. Wall cap: 3 ¼" x 10" = 40 ft (8.3 x 25.4 cm = !2.2rn)
F. 45 ° elbow: 6" = 5 ft (15.2 cm = 1.5 rn)
G. 90 ° flat elbow: 3¼" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
Recommended Vent Length
A 31/4"x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent
should be used.
The total length of the vent system including straight vent,
elbow(s), transitions and wall or roof caps must not exceed the
equivalent of 140 ft (42.7 m) for either type of vent. See
"Recommended Standard Fittings" section for equivalent lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the equivalent
length for each vent piece used in the system. See the following
examples:
C D
A. Two 90 ° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (O.6 rn) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
Ifthe existing vent is round, a rectangular to round transition piece
must be used. In addition, a rectangular 3" (7.6 cm) extension vent
between the damper assembly and rectangular to round transition
piece must be installed to keep the damper from sticking.
INSTALLATION
REQUIREMENTS
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
• Measuring tape •
• Pencil •
• Masking tape or thumbtacks
• Scissors
• No. 2 Phillips screwdriver
• No. 3 Phillips screwdriver for
1/4-20 x 3" round-head bolts •
Electric drill
3/16" (5 mm), 3/8" (9.5 mm)
drill bits
• 3/4" (19 mm) hole saw
Stud finder
7/16" socket wrench
(or box wrench) for 1/4" x 2"
lag screws
11/2"(4 cm) diam. hole drill
bit for wood or metal
cabinet
Keyhole saw
Caulking gun and
weatherproof caulking
compound
Duct tape
Parts Supplied
For reorder information, see "Replacement Parts" section.
NOTE: The hardware items listed here are for wood studs. For
other types of wall structures, be sure to use appropriate
fasteners.
F
Special Requirements
For Wall Venting Installation Only:
• The 12" x 4" (30.5 x 10.2 cm) cutout area must align with the
rectangular hole in the mounting plate.
• Cutout must be free of any obstructions so that the vent tube
fits properly, and the damper blade opens freely and fully.
For Roof Venting Installation Only:
• If using rectangular to round transition piece, the 3" (7.6 cm)
clearance needs to exist above the microwave oven so that
the damper blade can open freely and fully. See "Rectangular
to Round Transition" illustration in "Venting Design
Specifications" section.
Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See "Electrical Requirements" section.
A. 1/4-20 x 3" bolts (6)
B. Washers (2)
C. Toggle nuts (4)
D. 1/4" x 2" lag screws (4)
E. Pewer supply cord bushing (!)
F Damper assembly (for wall or roof
venting)
NOTE: Depending on model, aluminum grease filter and charcoal
filter may be combined.
Materials needed
• Standard fittings for wall or roof venting. See "Venting Design
Specifications" section.
Check the opening where the microwave oven will be installed.
The location must provide:
• Minimum installation dimensions. See ""Installation
Dimensions" illustration.
• Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum 3/8" (9.5 mm) thickness drywall or plaster/lath within
cabinet opening.
• Support for weight of 150 Ibs (68 kg), which includes
microwave oven and items placed inside the microwave oven
and upper cabinet.
• Grounded electrical outlet inside upper cabinet. See
"Electrical Requirements" section.
Not Shown:
Upper cabinet template
Mounting plate (attached to
back of microwave oven)
Aluminum grease filters
Charcoal filters (Depending
on model, charcoal filters
may not be included. See
Use and Care Guide.)
}
66" (167.6 cm) rain.
.............................. I
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
u_u_d* IJIYI+>+ ,,;_Oll_J
• If installing the microwave oven near a left sidewall, make sure
NOTES: T
there is at least 6" (15.2 cm) of clearance between the wall and
the microwave oven, so that the door can open fully. 171/8,,
• Some cabinet and building materials are not designed to (43.5cm)
withstand the heat produced by the microwave oven for |
cooking. Check with your builder or cabinet supplier to make
sure that the materials used will not discolor, delaminate or
sustain other damages.
l
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord,
Failure to follow these instructions can result in death,
fire, or electrical shock.
Observe all governing codes and ordinances. A 120 Volt, 60 Hz,
AC only, 15- or 20-amp fused electrical supply (or circuit breaker)
is required. (A time-delay fuse or circuit breaker is recommended.)
It is recommended that a separate circuit serving only this
appliance be provided.
INSTALLATIONINSTRUCTIONS
GROUNDING iNSTRUCTiONS
[] For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
SAVE THESE iNSTRUCTiONS
lVtot t" ng ?/c£®
I.
Remove any remaining contents from the microwave oven
cavity.
2.
Remove the mounting plate by peeling off the strips of tape
that attach it to the back of the microwave oven, and set the
mounting plate aside.
A B C
ul
O--
\ 0"_ ...................... _'0
g ® • • ® ® ® • ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® g
A. Back of microwave oven
B. Mounting plate
C. Tape (multiple locations)
3. Tape microwave oven door closed so that door does not
swing open while microwave oven is being handled.
NOTE: Do not grip or use the door or door handle while the
microwave oven is being manipulated.
A Deflec'kx-
The microwave oven is set for ventless (recirculating) installation.
For wall or roof venting, changes must be made to the venting
system.
NOTE: Skip this section if you are using ventless (recirculating)
installation. Keep the damper assembly in case the venting
method is changed, or the microwave oven is reinstalled in
another location where wall or roof venting may be used.
Wall Venting Installation Only
1. Remove screw attaching damper plate to top of microwave
oven exterior, then slide damper plate away from retaining
tabs.
A
A. Retaining tabs
B. Damper plate
2. Keep damper plate and screw together and set aside.
3. Slideairdeflectoroutofmicrowaveoven.
A. Air deflector
4.
Rotate air deflector front to back so that deflector feet face the
front of the microwave oven, and the exhaust port (open end)
of air deflector aligns with microwave oven exhaust port.
A B
A. Microwave oven exhaust port
B. Deflector feet
C. Air deflector exhaust port (open end)
5,
Slide air deflector into the back of the microwave oven as
shown, making sure its exhaust port (open end) aligns with the
microwave oven exhaust port.
A B
Roof Venting Installation Only
1. Repeat Step 1 from "Wall Venting Installation Only."
2. Repeat Step 2 from "Wall Venting Installation Only."
3. Repeat Step 3 from "Wall Venting Installation Only."
4. Rotate air deflector so that deflector feet face the bottom of
the microwave oven, and the exhaust port (open end) of air
deflector aligns with microwave oven exhaust port.
A
A. Microwave oven exhaust port
B. Air deflector exhaust port (open end)
C. Deflector feet
Slide air deflector into the back of the microwave oven as
shown, making sure its exhaust port (open end) aligns with the
microwave oven exhaust port.
A. Microwave oven exhaust port
B. Deflector feet
C. Air deflector exhaust port (open end)
6,
Slide damper plate under the retaining tabs, then secure with
screw.
m
I
A. Retaining tabs
A. Microwave oven exhaust port
B. Air deflector exhaust port (open end)
C. Deflector feet
Slide damper plate under the retaining tabs. Save screw for
later use.
A. Retaining tabs
bscc e Stud(s}
NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within
install the microwave oven, the opening.
See illustrations in "Possible Wall Stud Configurations," 2. Mark the center of each stud, and draw a plumb line down
Possible Wall Stud Configurations
These depictions show examples of preferred installation configurations with the mounting plate.
each stud center. See illustrations in "Possible Wall Stud
Configurations."
No Wall Studs at Corner Holes
Figure 1
No Wall Studs at Corner Holes
Figure2
....... m k I
...... ( L __::_ rrs';_s';'%L;':s"_'w_'_'"C
°o°o°o°o°o°o°:o0........: d OoOoOoOoOoOooI
B I/ i
1;; 12i> _"E
!.
A................. o o o o o o o o o o o o o o o o • ...............
i
One Wall Stud at Two Corner Holes
) o o o o o o o o o o o o o o o o o o o o o
NOTE: If wall stud is behind vent opening, only ventless
(recirculating) or roof venting installation can be done.
Wall Studs at All Four Corner Holes
Figure3
A................• o -f o i
, v iI
o oo i
o°o o°o ° °o°o °o°o° ° _, °o°o° o°o°o°
ooOoOot o O-oooooooooooooooooooooooo ° o oOo o oOoOo_
B II [ II i
I
......................... i
.............A E A,E .......... _ °
a o o o o o oooooooooooooooooooooooo o o o o o o
i ..... J J"
I B
_ i Di i
! i
I li
Figure4
F
i = ...................... ' i
i ......... i
_ ................... _ !o ........... _o
o o o ,'s o o o o o o o o o o o o o o o o o o o o o o o o o o o ....
/-_ ................._.o o o o o o o o o ! o o o o o o o o o_. ;=,...¢.tp_""""'/'1, _ o
.......... i ! ...................! _:/ y" i
D .i; ! _........D D [ [ _'"""'" D
i: ! :i i ! i:
_i _ i _i _ i i
i , i i i '
i'; F >"F I [ F-'_'] [ .........F
A. Corner holes (on mounting plate)
B. Cabinet opening vertical centerline
C. Wall vent opening (on mounting plate)
D. Wall stud centerlines
E. Holes for lag screws
F. Support tabs
A,E
The microwave oven must be installed on a minimum of 1 wall
stud, preferably 2, using a minimum of 1 lag screw, preferably 2 or
more.
1. Using measuring tape, find and clearly mark the vertical
centerline of the opening.
A _
A. Centerline
2. With the support tabs facing forward (see illustrations in
"Possible Wall Stud Configurations" in "Locate Wall Stud(s)"
section), align the mounting plate to the centefline on the wall,
making sure it is level, and that the top of the mounting plate
is butted up against the bottom edge of the upper cabinet.
NOTE: If the front edge of the upper cabinet is lower than the
back edge, lower the mounting plate so that its top is level with
the front edge of the cabinet.
A ..........
C
B
A. Rear wall
B. Mounting plate
C. Top of mounting plate must align
with front edge of cabineL
D. Front edge of upper cabinet
3. Holding the mounting plate in place, mark the 4 corner holes.
4. Find the wall stud centerline(s) marked in Step 2 of "Locate
Wall Stud(s)," and mark at least 1, preferably 2 or more, hole(s)
through the mounting plate, closest to the centerline(s). See
figures 1, 2 and/or 3 in "Possible Wall Stud Configurations" in
"Locate Wall Stud(s)" section. The blackened holes in the
shaded areas are ideal hole locations.
5. Set mounting plate aside.
Wall Venting Installation Only
Centerline
Upper Cabinet Bottom
t
4" (10.2 cm)
f-'-' I
•
6" (15.2 cm)
6. Mark the centerline 3/8" (1cm) down from the bottom edge of
the upper cabinet.
7. Using measuring tape, measure out 6" (15.2 cm) on both sides
of the centefline, and mark.
8. Measure down 4" (10.2 cm) from the mark made in Step 6,
and mark.
9. Using a straightedge, draw the 2 horizontal, level lines through
the marks made in steps 6 and 8.
10. Draw the 2 vertical, plumb lines down from the marks made in
Step 7 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle.
This is the venting cutout area.
11. Cut a 3/4" (19 mm) hole in one corner of the cutout area.
12. Using a keyhole saw, cut out the venting cutout area.
In addition to being installed on at least 1wall stud, the mounting
plate must attach to the wall at all 4 corner holes. If the holes are
not over wall studs, use four 1/4-20 x 3" bolts with toggle nuts; if 2
holes are over wall studs, use 2 each of lag screws and 1/4-20 x
3" bolts with toggle nuts; or if all 4 holes are over wall studs, use
4 lag screws. Following are 3 installation configurations.
Installation for No Wall Studs at Corner Holes
(Figures 1 & 2)
1. Drill 3/4" (19 mm) holes through the wall at all 4 corner holes
marked in Step 3 of "Mark Rear Wall."
2. Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s)
marked in Step 4 of "Mark Rear Wall." Refer to figures 1and 2
in "Possible Wall Stud Configurations" in "Locate Wall Stud(s)"
section.
Installation for One Wall Stud at Two Corner Holes
(Figure 3)
6" (15.2 cm)
1. Drill 3/16" (5 mm) holes into the wall stud at the 2 corner holes
marked in Step 3 of "Mark Rear Wall."
2. If installing on a second wall stud, drill 3/16" (5 mm) hole(s)
into the wall stud at the holes marked in Step 4 of "Mark Rear
Wall." Refer to Figure 3 in "Possible Wall Stud Configurations."
in "Locate Wall Stud(s)" section.
3. Drill 3/4" (19 mm) holes through the wall at the other 2 corner
holes.
Installation for Wall Studs at All Four Corner Holes
(Figure 4)
1. Drill 3/16" (5 mm) holes into the studs at the 4 corner holes
marked in Step 3 of "Mark Rear Wall."