Whirlpool GGE350LW User Manual

Freestanding Electric Range with Double Ovens
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
GGE350LW
Electrical:
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating label. The model/serial number rating label is located on the bottom right front of the toe kick plate. Refer to the figures in the “Product Dimensions” section of the “Location Requirements” section.
This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
*The NEC calculated load is less than the total connected load listed on
the model/serial rating label.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈
" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
CABINET OPENING DIMENSIONS
®
A
C
E*
A. " (119.9 cm)
46 35
⁷⁄₈ ⁷⁄₈
B. Model/serial number rating
l front of the toe kick plate)
a
l (loc
e
b
a
o
on b
d
e
t
ttom
rig
ht
D
C. " (91.4 cm)
⁷⁄₈
75.
(
"
29
D.
E.
27¼" (66.8 - 69.2 cm)*
⁵⁄₁₆
26
B
)
cm
9
*Excludes handle. Dimension given is from wall to front of oven
door and will vary based on electric outlet receptacle installation.
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls with zero clearance.
*
NOTE:
24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1⁄4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
A
C
B
D
G
F
E
H
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop, see NOTE.
D. 30" (76.2 cm) min. opening
width
E. Cabinet door or hinge should
not extend into cutout.
*Nothing located in shaded areas can extend more than 1½"
(3.8 cm) from wall or range will not slide all the way back.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
F. 3-wire shaded area -
7" (17.8 cm) min. from left side cabinet, 5¾" (14.6 cm) max. from floor, 6" (15.2 cm) max. width*
G. 4-wire shaded area -
10" (25.4 cm) min. from right side cabinet, 5¾" (14.6 cm) max. from floor, 6" (15.2 cm) max. width*
H.
1½" (3.8 cm) min. from floor if
using a flush mount outlet.
Ref. W10270322A
8/28/09