or visit our website at... www.whirlpooLcom
Table of Contents ................................................ 2
W10049540
TABLEOFCONTENTS
DRYER SAFETY .............................................................................. 3
INSTALLATION INSTRUCTIONS .................................................. 4
Tools and Parts ............................................................................ 4
Options ......................................................................................... 4
Location Requirements ............................................................... 5
Electrical Requirements ............................................................... 7
Electrical Connection ................................................................... 9
Venting Requirements ................................................................ 14
Plan Vent System ....................................................................... 15
Install Vent System ..................................................................... 16
Install Leveling Legs ................................................................... 16
Connect Vent .............................................................................. 17
Level Dryer ................................................................................. 17
Complete Installation ................................................................. 17
DRYER USE .................................................................................. 18
Starting Your Dryer ..................................................................... 18
Stopping Your Dryer ................................................................... 19
Pausing or Restarting ................................................................. 19
Control Locked ........................................................................... 19
Drying and Cycle Tips ................................................................ 19
Status Lights ............................................................................... 20
Cycles ......................................................................................... 20
Additional Features .................................................................... 21
Drying Rack ................................................................................ 22
DRYER CARE ................................................................................ 23
Cleaning the Dryer Location ....................................................... 23
Cleaning the Lint Screen ............................................................ 23
Cleaning the Dryer Interior ......................................................... 23
Removing Accumulated Lint ...................................................... 24
Vacation and Moving Care ......................................................... 24
Changing the Drum Light ........................................................... 24
TROUBLESHOOTING .................................................................. 25
ASSISTANCE OR SERVICE ......................................................... 27
WARRANTY .................................................................................. 28
DRYERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
Read all instructions before using the dryer.
Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry-
cleaning soivents, or other flammable or explosive
substances as they give off vapors that could ignite or
explode.
Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
Do not reach into the dryer if the drum is moving.
Do not install or store the dryer where it will be exposed
to the weather.
Do not tamper with controls.
SAVE THESE iNSTRUCTiONS
Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair
instructions that you understand and have the skills to
carry out.
Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
Clear] lint screen before or after each load.
Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
m The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
See installation instructions for grounding requirements.
INSTALLATIONINSTRUCTIONS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
• Flat-blade screwdriver • Vent clamps
• #2 Phillips screwdriver • Caulking gun and
• Adjustable wrench that
opens to 1" (2.5 cm) or new exhaust vent)
hex-head socket wrench • Tin snips (new vent
(for adjusting dryer feet) installations)
• Wire stripper (direct wire • 1/4"nut driver
installations) (recommended)
• Level • Tape measure
Parts supplied
Remove parts packages from dryer drum. Check that all parts are
included.
• Parts package
4 Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a
pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
• For close-clearance installations between 31.5" (80.01 cm)
and 37" (93.98 cm), see "Plan Vent System" section for
venting requirements.
I_- 37" --_1
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the "Assistance
or Service" section of this manual.
compound (for installing
(93.98 cm)
Pedestal
Are you placing the dryer on a pedestal? You have the option of
purchasing pedestals of different heights separately for this dryer.
You may select a 10" (25.4 cm), a 13" (33 cm) or a 15.5" (39.4 cm)
pedestal. These pedestals will add to the total height of the dryer
for a total height of approximately 48" (121.9 cm), 51" (129.5 cm)
or 53.5" (135.9 cm), respectively.
For a garage installation, you will need to place the 10" (25.4 cm)
pedestal at least 9" (22.9 cm) above the floor and the 13" (33 cm)
pedestal at least 6" (15.2 cm) above the floor. You will need to
place the 15.5" (39.4 cm) pedestal at least 3.5" (8.9 cm) above
the floor.
Optional pedestal
The pedestals are available in several colors.
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section of this manual.
Pedestal Color Part Number
Height
10" (25.4 cm) White WHP1000SQ
10" (25.4 cm) Biscuit WHP1000ST
10" (25.4 cm) Pewter WHP1000SL
10" (25.4 cm) Diamond Dust WHP1000SU
(Silver)
13" (33 cm} White LAB2700MQ
13" (33 cm) Biscuit LAB2700MT
13" (33 cm} Pewter LAB2700ML
15.5" (39.4 cm) White WHP1500SQ
15.5" (39.4 cm) Biscuit WHP1500ST
15.5" (39.4 cm) Pewter WHP1500SL
15.5" (39.4 cm) Diamond Dust WHP1500SU
(Silver)
Stack Kit
Are you planning to stack your DUET ®washer and dryer? To do
so, you will need to purchase a Stack Kit.
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section of this manual. Ask
for Part Number 8541503.
Door Reversal Kit
Are you planning to reverse the door swing direction on your
DUET®dryer? To do so, you will need to purchase a Door
Reversal Kit.
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section of this manual. Ask
for Part Number 8530069 (Shield Blue), 8530070 (Shield
Platinum), 8530071 (Biscuit), 8530072 (Pewter) or 8579123
(Diamond Dust [Silver]).
Door Reversal and Stack Combination Kit
Are you planning to reverse the door swing direction on your
DUET®dryer and stack your DUET®washer and dryer? To do so,
you can purchase a Door Reversal and Stack Combination Kit.
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section of this manual. Ask
for Part Number 8530073 (Shield Blue), 8530074 (Shield
Platinum), 8530075 (Biscuit), 8530076 (Pewter) or W10057200
(Diamond Dust [Silver]).
Backguard
If you are installing your DUET° washer and dryer and wish to
avoid having loose items fall behind your machines, you may
purchase a pair of washer/dryer backguards. These will reduce
the chance of items falling behind the machines during operation.
To order, call the dealer from whom you purchased your dryer or
refer to the "Assistance or Service" section of this manual. Ask
for Part Number 8558694 (White), 8558695 (Biscuit), 8558696
(Pewter), or W10057220 (Diamond Dust [Silver]).
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
P_ace dryer at _east 18 inches (48 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
• A location that allows for proper exhaust installation. See
"Venting Requirements."
• Aseparate 30-amp circuit.
• If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (61 cm) of either side of the dryer.
See "Electrical Requirements."
• A sturdy floor to support the total dryer weight of 200 Ibs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. If slope is greater than 1" (2.5 cm), install Extended
Dryer Feet Kit, Part Number 279810. Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If you are using a 10"
(25.4 cm) pedestal, you will need to place the pedestal at
least 9" (22.9 cm) above the floor. With a 13" (33 cm)
pedestal, you will need to place the pedestal at least
6" (15.2 cm) above the floor. With a 15.5" (39.4 cm) pedestal,
you will need to place the pedestal at least 3.5" (8.9 cm)
above the floor.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
38'I
(98=52cm)
(80 cm) 27"
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of O" (Ocm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
• Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
• Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
Closet installation - Dryer only
24 in? _
(155cm2)
(7=6cm)
I1"*1_5!,J2"_'15"**1
(2=5cm) (80cm) {12=7cm)
A B
A. Side view - closet or confined area
B.Closet door with vents
*Required spacing
**For side or bottom venting, O" (Ocm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
=
1 -1-1414,,mox,
1
(2=5cm) (88=8cm)
A B
A. Recessed area
B. Side view - closet or confined area
*Required spacing
**For side or bottom venting, O" (Ocm) spacing is allowed.
(2.5 cm) (2.5cm) {80 cm) {12.7cm)
1"*1I<- 31,J_"--_15"**1
cm)
*Required spacing
1"* _ _._27"_ _-- 1"*
2=5cm 68=5cm 2=5cm
Installation spacing for cabinet installation
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
• m) 7"*(17.8cm)
,I
5"** 31W' 1"*
(12.7 cm) (80.0 crn) (2.5 crn) (2.5 cm)(68.6 cm) (2.5 crn)
*Required spacing
**For side or bottom venting, O" (Ocm) spacing is allowed.
1" 27" 1"
9"*
(22.0 crn)
Recommended installation spacing for recessed or
closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
48 i_=2 *
(310 cm 2}
3'* (7.6 cm}
o
3_
3"* {7=6 cm}
24 in=_ _
(155 em_}
•Required spacing
6"* {15=2 cm)
76"
{193 cm}
\_ .¢/
5"*-_
(12=7cm)
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240
MH.
Mobile home installations require:
• Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
_- 27" _ -,,_- 1"
6&6 cm 2=5cm
It is your responsibility
• Tocontact a qualified electrical installer.
• To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
• Do not use an extension cord.
• If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
• If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection" section.
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor (white wire)
within the dryer. Ifthe dryer is installed with a 4-wire electrical
supply connection, the neutral ground wire must be removed
from the external ground conductor screw (green screw), and
secured under the neutral terminal (center or white wire) of
the terminal block. When the neutral ground wire is secured
under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
Ifusingapowersupplycord:
UseaULlistedpowersupplycordkitmarkedforusewith
clothesdryers.Thekitshouldcontain:
• AULlisted30-amppowersupplycord,rated
120/240voltminimum.ThecordshouldbetypeSRDor
SRDTandbeatleast4ft(1.22m)long.Thewiresthat
connecttothedryermustendinringterminalsorspade
terminalswithupturnedends.
• AULlistedstrainrelief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper
wires and match a 4-wire receptacle of NEMA Type 14-30R. The
ground wire (ground conductor) may be either green or bare. The
neutral conductor must be identified by a white cover.
If your outlet looks like this:
3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL listed strain relief. The 3-wire power supply
cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper
wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
• Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
• 10-gauge solid copper wire (do not use aluminum).
• At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
m For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The piug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
m For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
suppiy cord: if it wilI not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Power Supply Cord Direct Wire
Fire Hazard
Use a new UL _isted 30 amp power supply cord.
Use a UL _isted strain retief,
Disconnect power before making e_ectdcal connections,
Connect neutra_ wire (white or center wire) to center
terminal (sHve0,
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (go_d).
Securely tighten all electricai connections,
Failure to do so can result in death, fire, or
electrical shock,
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
C
Fire Hazard
Use 10 gauge solid copper wire,
Use a UL _isted strain relief,
Disconnect power before making e_ectdca_ connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector,
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten aimelectdca] connections.
Failure to do so can result in death, fire, or
electrical shock.
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 3/4"(1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down