Electric Dryer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
GEQ8811L
GEQ8821K
GEQ8821L
GEQ9800L
Electrical: A four-wire or three-wire, single
phase, 120/240-volt, 60-Hz, AC-only, electrical
supply (or four-wire or three-wire, 120/208-volt if
specified on model/serial rating plate) is required
on a separate 30-ampere circuit, fused on both
sides of the line. Use 10 gauge solid copper wire.
A time-delay fuse or circuit breaker is
recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
Not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.
Closet confined area
4"
4"
Preferred
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 4" hood
Maximum length of 4"
diameter metal vent
0
1
2
3
4
64 ft.
54 ft.
44 ft.
35 ft.
27 ft.
36 ft.
31 ft.
27 ft.
25 ft.
23 ft.
Acceptable
Number of Rigid Flexible
90° elbows (fully extended)
When you have a 2-1/2" hood
Maximum length of 4"
diameter metal vent
0
1
2
3
4
58 ft.
48 ft.
38 ft.
29 ft.
21 ft.
28 ft.
23 ft.
19 ft.
17 ft.
15 ft.
2-1/2"
Select the route that will provide the straightest and most direct
path outdoors. Plan the installation to use the fewest number
of elbows and turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as
possible. Bend flexible metal vent gradually to avoid kinking.
Determine vent length
1. See the exhaust vent length chart that matches your type
hood for the maximum vent lengths you can use.
Do not use vent runs longer than specified in exhaust vent
length charts.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are using
(rigid or flexible), find the maximum length of metal vent on
the same line as the number of elbows.
The maximum length using a 2" x 6" rectangular vent with 2
elbows and a 2-1/2" exhaust hood is 8 ft.
3"
3"
48 sq. in
.**
24 sq. in.**
14"
max.
front view
1"
closet
door
0" *
0" *
front view
15"
If a closet door is installed: The minimum unobstructed air
openings are required. Louvered doors with equivalent air
openings are acceptable.
*Wall, door and floor molding may
require additional spacing.
side view
Recessed
Closet
Back
5"/0"
5"/0"
Sides
1"/0"
1"/0"
Top
18"/15"
18"/15"
Front
—
1"/1"
Recommended/Minimum
Recessed
area
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8535840
09-30-02
14"
power supply
cord/cable
strain relief
terminal block
cover
The dryer door
extends 14" from the
front of the dryer
when fully opened.
29-1/4" (models with flush
mounted door handle)
30-1/4" (models with extended
mounted door handle)
43-1/8"
11"
38-1/4"
27"
Dimensions shown
with feet extended 1"
from bottom of dryer.
*Most installations
will require at least
5" clearance behind
the dryer for the
dryer vent.
** Minimum top and bottom air
openings for closet door.
*** External exhaust elbow requires
recommended spacing.
spacing
5" is recommended ***
0" is minimum
0"*
0"*
15"
* Wall, door and floor molding may require
additional spacing.
Front view