Whirlpool FGH 5400 IN PROGRAM CHART

4gb66007.fm5 Page 1 Thursday, January 24, 2002 5:07 PM
FGH 5400
NL
PRODUCT DESCRIPTION SHEET
Removable panstand grids
1.
Medium burner
2.
Large burner
3.
Simmer burner
4.
Medium burner
5.
Medium burner control knob
6.
Large burner control knob
7.
Simmer burner control knob
8.
Medium burner control knob
9.
Symbols
Shaded
circle
Large
flame
and star
Small
flame
Tap closed
Maximum opening/
delivery
Minimum opening or
reduced delivery
OPERATION OF BURNERS
To light one of the burners:
Press the relative knob and turn it anti-
At the same time, keeping the knob
pressed, approach a flame to the burner.
- After ignition of the of the burner,
release the knob.
If the burner does not ignite, repeat
the operations described above.
5019 419 66007
Note:
Should particular local conditions of the
-
delivered gas make the ignition of the
burner difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
4gb66007.fm5 Page 2 Thursday, January 24, 2002 5:07 PM
DIMENSIONS OF COOKING HOB
AND WORKTOP (mm)
NOTES: if the distance A between the wall cabinets is between 600 mm and
680 mm, the height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of
the cooktop, the height B must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas
used
NATURAL
GAS
(Methane)G 25
Type of gas
used
G 25 25 mbar 4 gas 7.80 865 l/h 15.6
Type of
burner
large
medium
simmer
Appliance
model
Injector
marking
130
100
67
Rated
heat
capacity
Pcs-kW
2.90
2.00
0.90
Total rated
heat capacity
Pcs-kW
Rated
consump-
tion
321 l/h
222 l/h
100 l/h
Reduced
heat
capacity
Pcs-kW
0.49
0.33
0.22
Total rated
consumption
Gas pressure in
Mbar
min. rat. max.
20 25 30
Air required
for burning
3
m
/h
Loading...