• Download the complete instruction manual on docs.whirlpool.eu or call the phone
number shown on the warranty booklet.
• Before using the appliance, read these safety instructions. Keep them nearby for future
reference.
• These instructions and the appliance itself provide important safety warnings, to be
observed at all times. The manufacturer declines any liability for failure to observe these
safety instructions, for inappropriate use of the appliance or incorrect setting of controls.
The appliance uses ammable refrigerant (R290),the maximum refrigerant charged
amount is 0.058kg.The appliance shall be installed, operated and stored in a room with a
oor area larger than 4 m
Very young children (0-3 years) should be kept away from the appliance. Young children
(3-8years) should be kept away from the appliance unless continuously supervised.
Children from 8years old and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge can use this appliance only
if they are supervised or have been given instructions on safe use and understand
the hazards involved. Children must not play with the appliance. Cleaning and user
maintenance must not be carried out by children without supervision.
Do not use the drained water for humans or pets
2
. And the room should higher than 2.2 m.
PERMITTED USE
CAUTION: the appliance is not intended to be operated by means of an externa l
switching device, such as a timer, or separate remote controlled system.
This appliance is intended to be used in household and similar applications such as:
hotels and working oces.
This appliance is not for professional use. Do not use the appliance outdoors.
Do not use the appliance in environments with ambient temperature below 0°C, as this
could cause the water in the hoses to freeze and damage the appliance.
Ensure that the water bucket is empty before moving the unit. - Risk of electric shock or
re.
Always turn o the dehumidier by power button on product panel rst. Do not use
the power supply circuit breaker or pull o the plug to turn it o. Disconnect the
dehumidier from the power supply if it is to be left unused for a long period of time or
during a thunder/lightning storm.
Never insert obstacle in the air outlet (risk of injury). Keep ventilation openings clear of
any obstruction.
- 4 -
SAFETY INSTRUCTIONS
INSTALLATION
The appliance must be handled and installed by two or more persons - risk of injury. Use
protective gloves to unpack and install - risk of cuts.
Installation, including electrical connections, and repairs must be carried out by a
qualied technician according to national wiring rules.
Do not repair or replace any part of the appliance unless specically stated in the user
manual.
Keep children away from the installation site. After unpacking the appliance, make sure
that it has not been damaged during transport.
In the event of problems, contact the dealer or your nearest After -sales Service. Once
installed, packaging waste (plastic, styrofoam parts etc.) must be stored out of reach of
children - risk of suocation.
The appliance must be disconnected from all remote power supply before any
installation operation - risk of electric shock.
During installation, make sure the appliance does not damage the power cable - risk
of re or electric shock. Only activate the appliance when the installation has been
completed.
Always leave a 20 cm gap around the appliance and a 50 cm gap above it.
Insucient ventilation may cause overheating or re.
To avoid potential re hazards, ensure that the lter is installed before operating the
appliance.
Do not place the appliance near a heat source (risk of re).
Avoid keeping ammable materials, such as alcohol, petrol or aerosols, near the
appliance (risk of explosion or re).
Operate the appliance only on a level and stable surf ace.
Disconnect power cord before moving the appliance.
ELECTRICAL WARNINGS
The power supply must be of rated voltage with special circuitry for the appliance. The
diameter of the power cord must comply with requirements.
It must be possible to disconnect the appliance from the power supply by unplugging.
The appliance must be earthed in conformity with national electrical safety standards.
The use of a time-delay fuse or time-delay circuit breaker is recommended. All wiring
must comply with local and national electrical regulations and be installed by a qualied
electrician.
Do not use extension leads, multiple sockets or adapters. The electrical components
must not be accessible to the user after installation. Do not use the appliance when you are
wet or barefoot. Do not operate this appliance if it has a damaged power cable or plug, if it
is not working properly, or if it has been damaged or dropped.
If the supply cord is damaged, it must be replaced with an identical one by the
manufacturer, its service agent or similarly qualied persons in order to avoid a hazard risk
of electrical shock.
Ensure safe grounding and a grounding wire connected with the special grounding
system of the building, installed by professionals. The appliance must be tted with
electrical leakage protection switch and an auxiliary circuit breaker with sucient capacity.
The circuit breaker must also have a magnetic and a thermal tripping function to ensure
protection in case of short-circuit and overload.
- 5 -
SAFETY INSTRUCTIONS
CLEANING AND MAINTENANCE
WARNING: Ensure that the appliance is switched o and disconnected from the
power supply before performing any maintenance operation; never use steam cleaning
equipment - risk of electric shock.
DISPOSAL OF PACKAGING MATERIALS
• The packaging material is 100% recyclable and is marked with the recycle symbol . The various parts of the packaging must
therefore be disposed of responsibly and in full compliance with local authority regulations governing waste disposal.
DISPOSAL OF HOUSEHOLD APPLIANCES
• This appliance is manufactured with recyclable or reusable materials. Dispose of it in accordance with local waste disposal
regulations. For further information on the treatment, recovery and recycling of household electrical appliances, contact your local
authority, the collection service for household waste or the store where you purchased the appliance. This appliance is marked in
compliance with European Directive 2012/19/EU, Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is
disposed of correctly, you will help prevent negative consequences for the environment and human health.
The symbol
but must be taken to an appropriate collection center for the recycling of electrical and electronic equipment.
on the product or on the accompanying documentation indicates that it should not be treated as domestic waste
DECLARATION OF CONFORMITY
• The refrigerant gas being in a hermetically sealed system (R290, GWP 3 ).
Explanation of symbols displayed unit.
WARNING
CAUTION
CAUTION
This symbol shows that this appliance uses a flammable
refrigerant.
If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire
This symbol shows that the operation manual should be read
carefully
This symbol shows that a service personnel should be
handling this equipment with reference to the installation
manual
CAUTION
This symbol shows that information is available such as the
operating manual or installation manual
SAFETY INSTRUCTIONS FOR SERVICING APPLIANCE WITH SPESIFIC
REFRIGERANT
Download the complete manual for detailed installation, servicing, maintenance and repairing
methods on docs.whirlpool.eu.
- 6 -
SAFETY INSTRUCTIONS
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specied for operation; without continuously operating ignition
sources (such as; open ames, an operating gas appliance or an operating electric heater).
Do not pierce or burn. Be aware that the refrigerants may not contain an odor.
A ny person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certicate from an industry-accredited assessment authority, which
authorizes their competence to handle refrigerants safely in accordance with an industry
recognized assessment specication. Servicing shall only be performed as recommended
by the equipment manufacturer. Maintenance and repair requiring the assistance of other
skilled personnel shall be carried out under the supervision of the person competent in the
use of ammable refrigerants. Appliance shall be installed, operated and stored in a room
with a oor area larger than 4 m2. The installation of pipe-work shall be kept to a room with
a oor area larger than 4 m2.
The pipe-work shall be compliance with national gas regulations. The maximum refrigerant
charge amount is 0.058 kg.
When ared joints are reused , the are part shall be re fabricated.
1. Transport of equipment containing ammable refrigerants shall be compliant with the
transport regulations.
2. Marking of equipment using signs shall be compliant with local regulations.
3. Disposal of equipment using ammable refrigerants shall be compliant with national
Regulations.
4. The storage of equipment / appliances should be in accordance with the manufacturer’s
instructions.
5. Storage of packed (unsold) equipment Storage package protection should be
constructed such that mechanical damage to the equipment inside the package will not
cause a leak of the refrigerant charge. The maximum number of pieces of equipment
permitted to be stored together will be by local regulations.
6. Information on servicing.
6-1 Checks to the area
Prior to beginning work on system containing ammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating
system the following precautions shall be complied with prior to conducting work on the
system.
6-2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of
ammable gas or vapour being present while the work is being performed.
6-3 General work area
All maintenance sta and others working in the local area shall be instructed on the nature
of work being carried out. Work in coned spaces shall be avoided.
6-4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during
work, to ensure the technician is aware of potentially ammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with ammable refrigerants, i.e.
non-sparking adequately sealed or intrinsically safe.