MICROWAVE OVEN BUILT-IN TRIM KIT
INSTALLATION INSTRUCTIONS
Built-In Trim Kit Models MK1170XP, MK1177XP
UL listed for use over built-in electric ovens:
27" (68.6 cm): (Y)RBS275PD, (Y)GBS277PD, KEBI171D, (Y)KEBS177D
30" (76.2 cm): (Y)RBS305PD, GBS307PD, (Y)KEBI101D, (Y)KEBS107D
INSTRUCTIONS D’INSTALLATION
GARNITURE ENCASTRÉE POUR FOUR À MICRO-ONDES
Garniture pour modèles MK1170XP, MK1177XP
Homologation UL pour utilisation
au-dessus des fours encastrés électriques :
27" (68,6 cm) : (Y)RBS275PD, (Y)GBS277PD, KEBI171D, (Y)KEBS177D
30" (76,2 cm) : (Y)RBS305PD, GBS307PD, (Y)KEBI101D, (Y)KEBS107D
Table of Contents / Table des matières
MICROWAVE OVEN SAFETY................................................2
INSTALLATION INSTRUCTIONS ..........................................2
Tools Recommended...........................................................2
Parts Supplied......................................................................2
Cutout Dimensions...............................................................2
Electrical Requirements........................................................3
Microwave Oven Preparation...............................................3
Bottom Duct Assembly ........................................................3
Side Duct and Upper Duct Assembly..................................3
Anti-Tip Bracket Installation.................................................4
Microwave Oven Placement ................................................4
Trim Kit Frame Installation....................................................5
SÉCURITÉ DU FOUR À MICRO-ONDES .................................5
INSTRUCTIONS D'INSTALLATION ..........................................6
Outillage recommandé.............................................................6
Pièces fournies.........................................................................6
Dimensions pour le découpage...............................................6
Spécifications électriques........................................................6
Préparation du four à micro-ondes .........................................7
Assemblage du conduit du bas...............................................7
Assemblage du conduit latéral et du conduit supérieur .........7
Installation de la bride antibasculement..................................8
Mise en place du four à micro-ondes......................................8
Installation du cadre de garniture............................................8
IMPORTANT: Save Installation Instructions for local electrical inspector’s use.
IMPORTANT : Conserver ces instructions d’installation à l’usage de l’inspecteur local des installations électriques.
8205556/3828W5U0443
MICROWAVE OVEN SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or
“WARNING.” These words mean:
You can be killed or seriously injured if you don't
immediately follow instructions.
can be killed or seriously injured if you don't
You
follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can
happen if the instructions are not followed.
INSTALLATION INSTRUCTIONS
Tools Recommended
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
■ Measuring tape
■ Pencil
■ Scissors
Parts Supplied
ABCDE
FGHIJ
A. Trim kit frame
B. Side duct (1)
C. 1" screws (4, plus 2 extra)
¹⁄₂
" screws (15, plus 2 extra)
D.
E. Anti-tip bracket (1)
■ #2 Phillips screwdriver
■ ⁵⁄₆₄" drill
F. Bottom duct floor (1)
G. Bottom duct supports (2)
H. Bottom bracket (1)
I. Upper duct (1)
J. Template (1)
Cutout Dimensions
B
WidthWidth
16³⁄₄"
(42.55 cm)
3"
(7.6 cm)
DIMENSIONSOVER 27" (68.6
CM) BUILT-IN
OVEN
Width 25¹⁄₂" (64.77 cm) 25¹⁄₂" (64.77 cm) min;
Depth 21" (53.34 cm) min. with flush mount
receptacle;
22³⁄₄" (57.79 cm) min. without flush mount
receptacle
Height 16³⁄₄" (42.55 cm) (for all models)
A
A. Width
B. Depth
OVER 30" (76.2 CM)
BUILT-IN OVEN
28¹⁄₂" (72.39 cm) max.
2
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Bottom Duct Assembly
1. Position supports over tabs of bottom duct floor, making sure
all 3 tabs are inside each support. Align the tab holes with the
screw holes on the sides of the supports. Fasten supports to
bottom duct floor with six ¹⁄₂" screws, as shown.
A
A.
¹⁄₂
" screws
2. Fasten bottom bracket to bottom duct using two ¹⁄₂" screws.
(Rear view of bottom duct)
Observe all governing codes and ordinances. A 120-Volt, 60-Hz,
AC-only, 15- or 20-amp fused electrical supply (or circuit breaker)
is required. (A time-delay fuse or circuit breaker is
recommended.) It is recommended that a separate circuit serving
only this appliance be provided.
GROUNDING INSTRUCTIONS
■ For all cord connected appliances:
The microwave oven must be grounded. In the event
of an electrical short circuit, grounding reduces the
risk of electric shock by providing an escape wire for
the electric current. The microwave oven is equipped
with a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is
properly installed and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the
are not completely understood
whether the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord
is too short, have a qualified electrician or serviceman
install an outlet near the microwave oven.
SAVE THESE INSTRUCTIONS
grounding instructions
, or if doubt exists as to
A
B
A. Bottom bracket
¹⁄₂
" screws
B.
3. Install bottom duct with two ¹⁄₂" screws.
(Front view of microwave oven)
A
A.
¹⁄₂
" screws
Side Duct andUpper DuctAssembly
1. Remove existing screw from left side of microwave oven.
2. Connect side duct to upper duct:
Insert projecting tabs of upper duct into holes of side duct.
Then bend tabs upward.
MicrowaveOven Preparation
1. Unplug microwave oven before proceeding with installation.
2. Remove any loose items inside microwave oven.
A
B
A. Tabs of upper duct
B. Holes in side duct
3