ARZ 904/H
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 07.07.2000 Subject to modification
Document-No.: 4812 721 16021
07.07.2000 / Page 2 ARZ 904/H Whirlpool Europe
Doc. No: 4812 721 16021 8586 904 10000 Customer Service
Technical data
Dimensions
Height 139.0 cm
Width 55.0 cm
Depth 58.5 cm
Capacity
Total
gross 235 l
net 228 l
Cooling
gross 187 l
net 180 l
Freezing
net 48 l
Electrical connection
SERVICE
Voltage 220 - 240 V
Frequency 50 Hz
Power consumption
in 24 hours 1.01 kWh
Freezing capacity
in 24 hours 2.5 kg
Compressor
Type HLY 90 AA
Capacity (CECOMAF) 109 W
Refrigerant
Type R 600 a
Quantity 56 g
Thermostat switching value
Switch on temperature min. + 6.0 ˚C
Switch on temperature max. + 6.0 ˚C
Switch off temperature min. - 19.0 ˚C
Switch off temperature max. - 33.0 ˚C