SERVICE
Model ART 535/G
Version 8564 535 10011 Page
Whirlpool Europe
Customer Services
ART 535/G
Service Manual
Freestanding Cooling
Double Door
ART 535/G
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 14.08.2002 Subject to modification
Document-No.: 4812 731 13391
14.08.2002 / Page 2 ART 535/G Whirlpool Europe
Doc. No: 4812 731 13391 8564 535 10011 Customer Service
Technical data
Factory Code RF 185 W
Dimensions
Height 122.6 cm
Width 49.9 cm
Depth 60.0 cm
Capacity
Total
gross 189 l
net 187 l
Cooling
gross 147 l
net 145 l
Freezing
net 42 l
net 42 l
SERVICE
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Power consumption
in 24 hours 0.95 kWh
Freezing capacity
in 24 hours 2 kg
Compressor
Type EMT 43 HLP
Capacity (CECOMAF) 96 W
Refrigerant
Type R 134 a
Quantity 105 g
Thermostat switching value
Switch on temperature min. + 4.5 ˚C
Switch on temperature max. + 4.5 ˚C
Switch off temperature min. - 19.0 ˚C
Switch off temperature max. - 33.0 ˚C