Whirlpool AKT 607/WH, AKT 607/NB, AKT 607/IX PROGRAM CHART

0 (0)
Whirlpool AKT 607/WH, AKT 607/NB, AKT 607/IX PROGRAM CHART

GB

AKT 607

PRODUCT DESCRIPTION SHEET

Destinations

FR

1.Removable panstand grids

2.Auxiliary burner

3.Semi-rapid burner

4.Semi-rapid burner

5.Ultra-rapid burner

6.Auxiliary burner control knob

7.Semi-rapid burner control knob

8.Semi-rapid burner control knob

9.Ultra-rapid burner control knob

DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)

SYMBOLS

Tap closed

Maximum flame

Minimum flame

LIGHTING THE BURNERS

To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .

Press the knob against the control panel to ignite the burner.

After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up. This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).

The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit, wait at least one minute before trying to light it again.

-The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough. In this case, repeat the operations described above.

PRATICAL ADVICE FOR USING THE BURNERS

For better burner performance, please stick to the following rules:

-Use pots and pans that fit the burners (see table on the right).

-Only use flat-bottomed pots and pans.

-Use the correct amount of water for cooking foods and keep the pot covered.

Burner

Pot Ø

 

 

ultra-rapid

from 24 to 26 cm

 

 

semi-rapid

from 16 to 22 cm

 

 

auxiliary

from 8 to 14 cm

 

 

NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.

INJECTOR TABLE

 

 

 

 

 

 

 

 

 

 

 

CATEGORY II2H3B/P

Type of gas used

 

 

Type of burner

Ø injector

Rated thermal

Rated

 

Reduced heat

 

Gas pressure (mbar)

 

 

 

 

 

 

flow rate kW

consumption

capacity kW

 

 

 

 

 

 

 

 

 

 

min.

rat.

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

ultra-rapid

136

3.50

333

l/h

0.60

 

 

 

 

 

 

semi-rapid

95

1.65

157

l/h

0.35

17

20

25

(Methane)

G20

auxiliary

78

1.00

 

95 l/h

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

ultra-rapid

94

3.50

254

g/h

0.60

 

 

 

 

PETROLEUM GAS

 

 

semi-rapid

67

1.65

120

g/h

0.35

25

30

35

(Butane-Propano) G30-G31

auxiliary

50

1.00

 

73 g/h

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

Configuration

 

Rated thermal

 

Total rated

 

 

Air necessary (m3) for the

used

 

model

 

flow rate kW

 

consumption

 

 

combustion of 1 m3 of gas

G20 20 mbar

 

4 burners

 

7.80

 

 

 

 

742 l/h

 

9.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G30-G31 30 mbar

 

4 burners

 

7.80

 

 

 

 

567 g/h

 

30.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SUPPLY: 230 V - 50 Hz

5019 319 01102

To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.