WHIRLPOOL AKT 477/IX User Manual

PRODUCT DESCRIPTION SHEET
EN
4
57
3 2
6
1
8
9
1. Removable panstand grids
2. 4-crown burner
3. Semi-rapid burner
4. Auxiliary burner
5. 4-crown burner control knob
6. Semi-rapid burner control knob
7. Auxiliary burner control knob
8. Induction zone control panel
9. Induction cooking zone
SYMBOLS
tap closed
Maximum flame
Minimum flame
Induction on/off
Induction key lock
Timer
FR
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
USE OF THE GAS BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up. This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough. In this case, repeat the operations described above.
PRACTICAL ADVICE FOR USING THE GAS BURNERS
For optimum burner performance, observe the following rules:
- Use pots and pans that fit the burners (see table on the right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and keep the pot covered.
PRACTICAL ADVICE FOR USING THE INDUCTION COOKING ZONE
- Use only pots with the symbol “INDUCTION SYSTEM”
- For existing pots and pans, use a magnet to check suitability: pots are unsuitable if they cannot be magnetically detected
- Use pots and pans that fit the burners (see table on the right)
5019 300 02756
Burner Pot Ø
Auxiliary 8 to 14 cm
Semi-rapid from 16 to 22 cm
4-crown from 24 to 26 cm
Induction zone Pot Ø
Ø 24 cm from 14 to 24 cm
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 730 mm, the height “B” must be a
minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the hob, the height “B” must be a minimum of 400 mm. In the event a hood is fitted above the hob, please refer to the hood assembly instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Ty pe o f g as u s e d Ty pe of burner Injector
NATURAL GAS (Methane) G20
NATURAL GAS (Methane) G25
LIQUEFIED PETROLEUM GAS (Butane) G30
LIQUEFIED PETROLEUM GAS (Propane) G31
Type of gas used Model configuration Rated thermal flow rate kWTotal rated consumption Air necessary (m3) for the
G20 20 mbar 3 burners 6.15 585 l/h 9.52
G25 25 mbar 3 burners 6.15 682 l/h 8.187
G30 28-30 mbar 3 burners 5.85 426 g/h 30.94
G31 37 mbar 3 burners 5.85 418 g/h 23.80
4-crown semi-rapid auxiliary
4-crown semi-rapid auxiliary
4-crown semi-rapid auxiliary
4-crown semi-rapid auxiliary
marking
139
95 78
139
95 78
90 67 50
90 67 50
Rated thermal flow rate kW
3.50
1.65
1.00
3.50
1.65
1.00
3.20
1.65
1.00
3.20
1.65
1.00
Rated consumption
333 l/h 157 l/h 95 l/h
388 l/h 183 l/h
111 l/h
233 g/h 120 g/h 73 g/h
229 g/h 118 g/h 71 g/h
Reduced heat
capacity kW
BE FR min. rat. max.
2.20
0.45
0.35
2.20
0.35
0.30
2.20
0.35
0.30
1.90
0.35
0.30
1.90
0.35
0.30
combustion of 1 m
Gas pressure mbar
17 20 25
20 25 30
20 28-30 35
25 37 45
3
of gas
ELECTRICAL SUPPLY: 220-240 V ~ 50/60 Hz ELECTRIC HOTPLATE POWER: 3000 W
USE OF THE INDUCTION COOKING ZONE
Key lock
Cooking zone controls and corresponding display
On/Off Timer
Button -
Heat setting indicator
Selected cooking zone indicator
Button +
FR
Control panel
Timer
The timer can be used to set a max. cooking time of 99 minutes (1 hour and 39 minutes). Set the desired time using buttons "+" and "-" of the timer function (see figure above). A few seconds after the button is pressed, the timer begins the countdown (the luminous dot of the selected cooking zone
starts flashing). Once the set time has elapsed, an acoustic signal sounds and the cooking zone switches off automatically. To deactivate the timer, press the “-” button until the display shows “0:0” or press the “+” and “-” buttons of the timer at the same time.
Minute minder
The minute minder can only be used when the hob is not in use and allows a maximum setting of 99 min. Press the button “+” below the timer indicators: the display shows the minutes for setting. Select the time desired using the buttons + and. After a few seconds the minute minder starts to count down. Once the set time has elapsed an acoustic signal sounds.
Important! The minute minder function can only be used when the hob is switched off; if it is then switched on, the minute minder countdown is automatically cancelled.
Control panel graphics shown in these instructions might not match exactly the graphics of your hob. Button's functions are the same for all hob models.
Switching the hob ON/OFF
To switch the hob on, press the button for approx. 2 seconds until the cooking zone displays light up. To switch off, press the same button until the displays switch off. If the hob has been used, the residual heat indicator “H” remains activated until the induction cooking zone has cooled.
The hob automatically switches off if no function is selected within 10 seconds of switching on.
Switching on and adjusting cooking zone
After switching on the hob and positioning the pot on the induction cooking zone, adjust the heat setting using the button +. After pressing the + button, the display shows heat setting 5. The cooking zone has different power levels that can be adjusted using the +/- buttons, going from “1”: min. heat setting to “9”: max. heat setting. The fast boil function (Booster), is shown on the display with the letter “P”.
Fast boil function (Booster)
This function makes it possible to exploit the hob's maximum power (for example to bring water to the boil very quickly). To select this function, press the button “+” unitl “P” appears on the display, or after switching the hob on, press the “-” button. In this case too, “P” appears on the display. After 10 minutes' use of the booster function, the appliance automatically sets the zone to level 9.
Switching off cooking zone
Select the cooking zone to be switched off by pressing the “+” or “-” key (a dot lights up at the bottom right hand side of the heat setting indicator). Press the key “-” to set the level to “0”. The cooking zone can also be switched off by pressing “+” and “-” buttons at the same time. The cooking zone switches off and the residual heat indicator “H” lights up
Key lock
This function locks the induction cooking zone controls to prevent accidental switching on by children. To activate the key lock function, switch the hob on and hold the button for three seconds: an acoustic signal sounds and a led indicator lights up below the key symbol to confirm activation. The control panel is locked with the exception of the OFF function. To unlock the controls, repeat the key lock procedure. The illuminated dot switches off and the hob is active again. The presence of cleaning water, liquid spilled from pots or any objects resting on the button below the symbol can accidentally activate or deactivate the key lock function.
Control panel indicators
Residual heat indicator.
The hob is fitted with a residual heat indicator for the induction cooking zone.
If the display shows , the cooking zone is still hot. If the residual heat indicator of a given cooking zone is lit, that zone can be used, for example, to keep a dish warm or to melt butter. When the cooking zone cools down, the display switches off.
Incorrect or missing pot indicator.
The hob features an automatic pot detection system. If no pot is detected, the display with the cooking zone power level indicator flashes. Make sure the pot is correctly positioned and that it has the characteristics given in the section “Before use”.
If no pot is detected after 60 seconds, the hob switches off.
REFERENCE TO LOCAL REGULATIONS
The installation and maintenance of the appliance must be carried out by a qualified skilled technician in accordance with the regulations in force, and in particular:
- Decree of 2 August 1977
Technical and Safety Rules applicable to fuel gas and liquefied hydrocarbon installations located within residential buildings and outbuildings.
- Standard DTU P 45 - 204
Gas installations (formerly DTU no. 61-1 - Gas installations April 1982 + supplement no. 1 of July 1984).
- Departmental Health Regulations
For appliances connected to the mains electricity supply.
- Standard NF C 15-100
Low-voltage electrical installations - Standards.
Loading...
+ 4 hidden pages