Whirlpool AKR 301/NB/S/01 Service Manual

SERVICE
Model AKR 301/NB/S/01 Version 8578 301 38010 Page
Whirlpool Europe Customer Services
AKR 301/NB/S/01
Service Manual
Gas hob AKR 301/NB/S/01
Technical data 2
Spare part list 3
Exploded view 4
Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 05.07.2001 Subject to modification Document-No.: 4812 725 14717
05.07.2001 / Page 2 AKR 301/NB/S/01 Whirlpool Europe Doc. No: 4812 725 14717 8578 301 38010 Customer Service
Technical data
1. Removable grids
2. Large burner
3. Rear medium burner
4. Front medium burner
5. Small burner
6. Control panel burner
Voltage: 230-240 V Frequency: 50 Hz
SERVICE
Type of gas used Type of
burner
Natural gas (Methane) G20
LPG (Butane) G30
LPG (Propane) G31
Type of gas used Appliance
G20 20 mbar 4G 7.30 695 l/h 14.6 G30 28-30 mbar 4G 7.30 531 g/h 14.6 G31 37 mbar 4G 7.30 521 g/h 14.6
large medium small
large medium small
large medium small
Injector
marking
model
140 103
86 88
66 52
88 66 52
Rated heat
capacity
(kW)
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity
(kW)
Rated
consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reducedheat
capacity
(kW)
1.20
1.00
0.70
1.20
1.00
0.70
1.20
1.00
0.70
Total rated
consumption
Gas pressure
(mbar)
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning (m3 /h)
Loading...