Whirlpool SBI 901 W, AKP 685/01 NB, AKP 682/IX INSTRUCTION FOR USE

81055-gb.fm5 Page 12 Saturday, March 31, 2001 5:00 PM
GB TABLE OF CONTENTS
INSTALLATION
ELECTRICAL CONNECTION
BEFORE USING THE OVEN
PROTECTING THE ENVIRONMENT
OVEN ACCESSORIES
COOKING CHART
CLEANING THE OVEN AND ACCESSORIES
TROUBLESHOOTING GUIDE
PAGE
PAGE
PAGE
PAGE
PAGE
PAGE
PAGE
PAGE
PAGE
13
14
15
15
15
16
17
18
19
AFTER SALES SERVICE
DECLARATION OF CONFORMITY CE
12
PAGE
PAGE
20
20
81055-gb.fm5 Page 13 Saturday, March 31, 2001 5:00 PM
INSTALLATION
Technical information for the installer
After removing the oven from its packaging, before making the connections place it on the polystyrene foam base to protect it from damage.
Do not attempt to lift the oven by the handle. Lift at the sides as shown in the figure (see arrow).
Check that the appliance has not been damaged in transit.
Oven dimensions and kitchen unit dimensions are shown in the opposite figure.
Kitchen units in contact with the oven must be heat resistant (80° C min).
Install the oven in the housing, lifting it at the sides, taking care not to trap the wires of the electrical supply cable.
For correct ventilation, follow the ventilation opening directions shown in the figure (500 min x 80 mm and 500 min x 50 mm inside the cabinet).
Secure the oven to the kitchen unit with screws (A) as shown.
The oven has also been designed for building-in under a cooktop.
NOTE:
To allow for proper ventilation, we recommend that you left an opening of at least 500 x 80 mm or an equivalent area in the lower section of the housing.
An additional opening of 5 mm is required between the oven top rim and the cooktop lower rim: this opening must not be closed by strips or housing crosspieces
13
81055-gb.fm5 Page 14 Saturday, March 31, 2001 5:00 PM
ELECTRICAL CONNECTION
Warning: Do not connect to the power
supply before you have finished connecting the oven.
Make sure the oven is installed and
connected to the electricity supply by a qualified technician in accordance with the manufacturers instructions and in compliance with local regulations.
The installer is responsible for the correct
electrical connection of the oven and the observance of the relative safety prescriptions.
The oven must be connected to the
electricity supply by means of an all-pole disconnect switch with minimum contact gap of 3 mm.
The oven must be earthed by law.
Do not use multiple plug adapters or
extension leads.
After the oven has been installed, the
electrical components must be inaccessible.
Make sure that the voltage shown on the
rating plate is the same as the power supply voltage in your home. The rating plate is on the front edge of the oven cavity (visible with oven door open).