AKM 514/01 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
2. Large burner
3-4. Medium burners
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Operation of burners with electric
ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, keep the knob pressed
against the control panel until the burner
ignites.
• Release the knob.
If the burner does n ot ignite, repeat the oper ati on s
described above.
Shaded
circle
Large
flame
and star
Small
flame
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
Note:
— Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
5019 319 53411/A
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
Note: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORIE II2L3B/P
Type of gas
used
NATU RA L GAS
(Methane) G25
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of gas used
G25 25 mbar 4 gas 7.30 809 l/h 14.6
G30 28-30 mbar 4 gas 7.30 531 l/h 14.6
G31 28-30 mbar 4 gas 6.35 453 g/h 12.7
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
100/mm
129
99
78
85
65
50
85
65
50
Rated heat
capacity
kW
3.00
1.65
1.00
2.62
1.43
0.87
2.62
1.43
0.87
Total rated heat
capacity
kW
Rated
consumption
332 l/h
183 l/h
111 l/h
218 g/h
120 g/h
73 g/h
187 g/h
102 g/h
62 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.35
0.60
0.35
0.30
0.60
0.35
0.35
Total rated
consumption
Gas pressure mbar
min. rat. max.
20 25 30
25 30 35
25 30 35
Air required
for burning
m
ELECTRIC SUPPLY: 230 V - 50 Hz
3
/h