Whirlpool AKM 489, AKM 488/IX, AKM489 / IX INSTRUCTION FOR USE

INSTRUCTIONS FOR USE
PRODUCT DESCRIPTION AND SYMBOLS
USING THE BURNERS
PRACTICAL ADVICE ON USING THE HOB
POSITIONING THE PAN SUPPORTS AND WOK SUPPORT
HOOD AND CABINETRY CLEARANCES (MM)
INJECTOR TABLE
SAFEGUARDING THE ENVIRONMENT
INSTALLATION (FLUSH AND TRADITIONAL FITTING)
GAS CONNECTION
ELECTRICAL CONNECTION
FIXING THE HOB TO THE WORK TOP. TRADITIONALLY FITTED MODEL
FIXING THE HOB TO THE WORK TOP. FLUSH FITTED MODEL
ADAPTION TO A DIFFERENT TYPE OF GAS SUPPLY
REPLACING THE INJECTORS
FITTING THE WOK BURNER
REGULATING THE MINIMUM FLOW LEVEL OF THE GAS TAPS
GENERAL CLEANING & MAINTENANCE
CARE AND MAINTENANCE OF THE GAS BURNERS
TROUBLESHOOTING GUIDE
AFTER SALES SERVICE
17
PRODUCT DESCRIPTION AND SYMBOLS
1. Removable pan supports
2. 1 kWh auxiliary burner
3. 1.65 kWh semi-fast burner
4. 3 kWh fast burner
5. 1.65 kWh semi-fast burner
6. Professional wok burner
7. Auxiliary burner control knob
8. Semi-fast burner control knob
9. Fast burner control knob
10. Semi-fast burner control knob
11. Professional wok burner control knob
Control Symbols
Off
Maximum flame
Minimum flame
USING THE BURNERS
To turn on one of the burners:
1. Turn the corresponding control knob
anticlockwise until the indicator coincides with
the maximum flame symbol .
2. Press the control knob to ignite the burner.
3. Once the burner has lit, keep the control knob
pressed for about 5 seconds to allow the safety thermocouple fitted to each burner to engage. The thermocouple will switch off the gas supply to the burner should the flame be accidentally lost (A gust of air, momentary interruption of gas supply or liquid spillage etc).
If the burner does not ignite within about 15 seconds, switch off the burner, check the fitting of the burner cap and plate for correct fitting. Wait at least 1 minute before trying again.
If the burner goes out when the control knob is released, the thermocouple did not engage. wait at least 1 minute before repeating steps 1 to 3.
18
PRACTICAL ADVICE ON USING THE HOB
Read the instructions to get the best out of your hob.
Use pans with a similar diameter to the burner
(see the table on this page).
Use flat bottomed pans except with the wok
support.
Do not use excessive water when cooking foods
and use the lid.
Ensure that pans are fully supported by the pan
supports and do not protrude over the edges.
You should never use:
two burners simultaneously with just one
container such as a fish kettle.
Important:
Do not rest or drag the pan supports upside down on the hob as this could scratch it.
Failure to comply with these recommendations could lead to the glass ceramic hob being damaged, or broken and the safety of your appliance being compromised.
Burner Pan diameter
wok fast semi fast auxiliary
from 24 to 26 cm from 24 to 26 cm from 16 to 24 cm from 8 to 14 cm
POSITIONING THE PAN SUPPORTS AND WOK SUPPORT
Position the pan supports and wok support as indicated in the diagram.
19
HOOD AND CABINETRY CLEARANCES (MM)
If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct height above the hob.
INJECTOR TABLE
CATEGORY: II2H3+
Type of gas
used
NATURAL
GAS
(Methane)
G20
LIQUID PETROLEUM GAS (Butane)
G30
LIQUID PETROLEUM
GAS (Propane)
G31
Ty p e o f burner
wok
fast
semi-fast
auxiliary
wok
fast
semi-fast
auxiliary
wok
fast
semi-fast
auxiliary
Injector
label
145 128
95 78
100
85 65 50
100
85 65 50
Control primary
air (X)
(mm)
11
11
6
-
-
-
-
-
-
-
-
-
Nominal
heat flow
kW
4,20 3,00 1,65 1,00
4,20 3,00 1,65 1,00
4,20 3,00 1,65 1,00
Nominal
consumption
400 l/h 286 l/h 157 l/h
95 l/
305 g/h 218 g/h 120 g/h
73 g/h
300 g/h 214 g/h 118 g/h
71 g/h
Reduced
heat flow
kW
1.40
0.90
0.40
0.30
1.40
0.90
0.40
0.30
1.40
0.90
0.40
0.30
Gas pressure
(mbar)
min. nom. max.
17 20 25
25 30 35
25 30 35
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
Electric Power: 230 V - 50 Hz
20
Configuration
model
5 burners 5 burners 5 burners
Nominal heat
flow kW
11,50 11,50 11,50
Overall nominal
consumption
1090 l/h
836 g/h 821 g/h
Required air (m3)
for the
combustion 1 m
of gas
9,52 30,94 23,80
3
Loading...
+ 9 hidden pages