Whirlpool AKM 260/WH, AKM 260/IX, AKM 260/AE/01, AKM 260/TF, AKM 260/JA PROGRAM CHART

...

 

AKM 260-262

PRODUCT DESCRIPTION SHEET

 

 

 

 

 

 

 

 

IT

PT

Operation of burners with safety device and electric ignition

To light one of the burners:

Press the relative knob and turn it anticlockwise to the large flame and star

setting .

At the same time, keep the knob pressed against the control panel until the burners ignites.

After the burner has ignited, keep the knob pressed for about 10 seconds.

Release the knob.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2-3. Medium burners

4.Large burner

5.Small burner

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Small burner control knob

Symbols

Shaded circle

Tap closed

Large flame

Maximum opening

and star

delivery and electric

 

ignition

Small flame

Minimum opening or

 

reduced delivery

Note:

Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the

operation with the knob turned to the small flame setting .

The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).

5019 319 60061/A

Whirlpool AKM 260/WH, AKM 260/IX, AKM 260/AE/01, AKM 260/TF, AKM 260/JA PROGRAM CHART

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTE: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

 

 

CATEGORY II2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated

 

 

 

 

Reduced

 

Gas pressure

 

Type of gas used

 

Type of

 

Injector

heat

Rated

 

 

heat

 

 

 

 

 

 

 

burner

 

marking

capacity

consumption

 

capacity

 

 

 

 

 

 

 

 

 

 

 

min.

 

rat.

 

max.

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

large

 

128

 

3.00

286 l/h

 

 

0.60

 

 

 

 

 

 

 

 

medium

 

94

 

1.65

157 l/h

 

 

0.35

17

 

20

 

25

(Methane)

G 20

 

 

 

 

 

 

 

 

small

 

76

 

1.00

95 l/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID PETROLEUM

 

large

 

85

 

3.00

218 g/h

 

 

0.60

 

 

 

 

 

 

GAS

 

 

medium

 

65

 

1.65

120 g/h

 

 

0.35

20

 

28-30

 

35

(Cylinder)

G 30

 

small

 

50

 

1.00

73 g/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID PETROLEUM

 

large

 

85

 

3.00

214 g/h

 

 

0.60

 

 

 

 

 

 

GAS

 

 

medium

 

65

 

1.65

118 g/h

 

 

0.35

25

 

37

 

45

(Cylinder)

G 31

 

small

 

50

 

1.00

71 g/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance

 

 

Total rated heat

 

Total rated

 

Air required

 

Type of gas used

 

 

 

 

 

for burning

 

 

model

 

 

capacity Pcs-kW

 

consumption

 

 

 

 

 

 

 

 

 

m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 20 20 mbar

 

 

4 gas

 

 

7.30

 

 

695 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 25 28-30 mbar

 

4 gas

 

 

7.30

 

 

531 g/h

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31 37 mbar

 

 

4 gas

 

 

7.30

 

 

521 g/h

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...