AKM 254 PRODUCT DESCRIPTION SHEET
CZ SK RO RU
Removable panstand grids
1.
Medium burners
2-3.
Large burner
4.
Small burner
5.
Medium burner control knob
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Electric ignition button
10.
Symbols
Shaded circle Tap closed
Large flame Maximum opening
delivery
Small flame Minimum opening
or reduced delivery
Operation of burners with electric
ignition
To light one of the burners:
• Press the relative knob and turn it
anti-clockwise to the large flame setting .
• At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, repeat the operation.
5019 319 01033/B
Note:
Should particular local conditions of the
—
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS
(Methane) G20
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G30 28-30 mbar 4 gas 7.30 531 g/h 30.94
G31 37 mbar 4 gas 7.30 531 g/h 30.94
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
Y 115
H2 98
X 72
Rated
heat
capacity
kW
3.00
1.65
1.00
87
3.00
65
1.65
50
1.00
87
3.00
65
1.65
50
1.00
Total rated heat
capacity kW
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
218 g/h
120 g/h
73 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
20 28-30 35
Air required
for burning
m3/h
ELECTRIC SUPPLY: 230 V ~ 50 HZ