Whirlpool AKM 254 NB INSTRUCTION FOR USE

AKM 254 PRODUCT DESCRIPTION SHEET
CZ SK RO RU
Removable panstand grids
1.
Medium burners
2-3.
Large burner
4.
Small burner
5.
Medium burner control knob
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Electric ignition button
10.
Symbols
Shaded circle Tap closed Large flame Maximum opening
delivery
Small flame Minimum opening
or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame setting .
If the burner does not ignite, repeat the operation.
5019 319 01033/B
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS (Cylinder) G30
LIQUID PETROLEUM GAS (Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 9.52 G30 28-30 mbar 4 gas 7.30 531 g/h 30.94 G31 37 mbar 4 gas 7.30 531 g/h 30.94
Type of burner
large medium small
large medium small
large medium small
Appliance model
Injector marking
Y 115
H2 98
X 72
Rated heat capacity kW
3.00
1.65
1.00
87
3.00
65
1.65
50
1.00
87
3.00
65
1.65
50
1.00
Total rated heat capacity kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
218 g/h 120 g/h
73 g/h
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
20 28-30 35
Air required for burning m3/h
ELECTRIC SUPPLY: 230 V ~ 50 HZ
Loading...