Whirlpool AKM 252/WH, KGN 5382 A2 FRESH PT, AKM 252/BR INSTRUCTION FOR USE

AKM 252 PRODUCT DESCRIPTION SHEET
GB IE
1. Removable panstand grids 2-3. Medium burners
4. Large burner
5. Auxiliary burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Auxiliary burner control knob
10. Timer control knob
Symbols
Electrically ignited gas burner user instructions
How to ignite one of the burners:
Push and turn the corresponding knob anti­clockwise until the reference is aligned with the high flame and star symbols .
At the same time hold the knob against the control panel until the burner ignites.
Let go of the knob.
If the burner fails to ignite, repeat the sequence.
Note:
- If problems with local gas supply impede burner
ignition, repeat the sequence by turning the knob to the low flame symbol .
Shaded circle
High flame and star
Low flam e Minimum aperture/supply
Valve closed Maximum aperture/supply
and electric ignition
Glass cover with safety valve
The cover is equipped with a safety valve which shuts off the supply of gas when the cover is closed. However, if the burner is not turned off when the cover is closed, gas will escape from the burner when the cover is reopened.
Make sure all the knobs are switched off before closing the cover.
Using the timer
This particular model features a mechanical timer which can time up to one hour of cooking.
Turn the knob clockwise until the reference is aligned with the desired cooking time.
When the set time elapses an acoustic signal is activated.
5019 319 61321
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20
LIQUIFIED PETROLEUM GAS
(Cylinder) G 30 LIQUIFIED
PETROLEUM GAS (Cylinder) G 31
Type of gas used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6 G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of burner
large medium small
large medium small
large medium small
Appliance model
Injector marking
128
94 76
85 65 50
85 65 50
Rated heat capacity
Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for burning
3
m
Gas pressure
/h
Loading...