AKM 252 PRODUCT DESCRIPTION SHEET
GB IE
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Auxiliary burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Auxiliary burner control knob
10. Timer control knob
Symbols
Electrically ignited gas burner user
instructions
How to ignite one of the burners:
• Push and turn the corresponding knob anticlockwise until the reference is aligned with
the high flame and star symbols .
• At the same time hold the knob against the
control panel until the burner ignites.
• Let go of the knob.
If the burner fails to ignite, repeat the sequence.
Note:
- If problems with local gas supply impede burner
ignition, repeat the sequence by turning the
knob to the low flame symbol .
Shaded
circle
High flame
and star
Low flam e Minimum aperture/supply
Valve closed
Maximum aperture/supply
and electric ignition
Glass cover with safety valve
The cover is equipped with a safety valve which
shuts off the supply of gas when the cover is
closed. However, if the burner is not turned off
when the cover is closed, gas will escape from the
burner when the cover is reopened.
• Make sure all the knobs are switched off
before closing the cover.
Using the timer
This particular model features a mechanical timer
which can time up to one hour of cooking.
• Turn the knob clockwise until the reference is
aligned with the desired cooking time.
• When the set time elapses an acoustic signal
is activated.
5019 319 61321
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL GAS
(Methane) G 20
LIQUIFIED
PETROLEUM GAS
(Cylinder) G 30
LIQUIFIED
PETROLEUM GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
128
94
76
85
65
50
85
65
50
Rated heat
capacity
Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
m
Gas pressure
/h